Direct Power Control of DFIG Connected to Unbalanced Power Grid

被引:0
|
作者
Pura, Piotr [1 ]
Iwanski, Grzegorz [1 ]
机构
[1] Warsaw Univ Technol, Inst Control & Ind Elect, PL-00662 Warsaw, Poland
来源
2013 8TH INTERNATIONAL CONFERENCE AND EXHIBITION ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER) | 2013年
关键词
direct power control; DPC; doubly-fed induction generator; DFIG; unbalanced grid;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents a control strategy, which allows doubly-fed induction generator (DFIG) to generate a sinusoidal stator currents and minimize an electromagnetic torque oscillations under unbalanced grid conditions. The control does not require a positive and negative sequence decomposition of the control variables, so the independent control of positive and negative sequence is not used. Instead of it, the reference signal for reference power is calculated for the main control algorithm, which is the direct power control (DPC). Proposed strategy reduces the machine's torque oscillations and causes, that the machine stator and rotor current does not exceed the rated values, what may happen in a classic DPC control, when the positive sequence component of the grid voltage drops. Simulation results with 2MW doubly fed induction machine model are presented in the paper.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A Novel Direct Power Control for DFIG With Parallel Compensator Under Unbalanced Grid Condition
    Gao, Shuning
    Zhao, Haoran
    Gui, Yonghao
    Zhou, Dao
    Terzija, Vladimir
    Blaabjerg, Frede
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2021, 68 (10) : 9607 - 9618
  • [2] Modeling and improvement of direct power control of DFIG under unbalanced grid voltage condition
    Zandzadeh, Mohammad Jafar
    Vahedi, Abolfazl
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 59 : 58 - 65
  • [3] Direct power control on the DFIG wind turbine under unbalanced grid voltage conditions
    Guo, Xiaoming
    He, Yikang
    He, Benteng
    Hu, Jiabing
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2008, 32 (13): : 86 - 91
  • [4] Current-based direct power control of a DFIG under unbalanced grid voltage
    Farshadnia, Mohammad
    Taher, Seyed Abbas
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 571 - 582
  • [5] Direct Power Control for DFIG under Unbalanced and Harmonically Distorted Grid Voltage in Stationary Frame
    Song, Yipeng
    Nian, Heng
    2014 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2014, : 1500 - 1506
  • [6] Direct Power Control with Referenced Torque and Reactive Power of Doubly Fed Induction Machine Connected to Unbalanced Grid
    Pura, Piotr
    Iwanski, Grzegorz
    2014 NINTH INTERNATIONAL CONFERENCE ON ECOLOGICAL VEHICLES AND RENEWABLE ENERGIES (EVER), 2014,
  • [7] Fractional Order Sliding Mode Based Direct Power Control of Grid-Connected DFIG
    Xiong, Linyun
    Wang, Jie
    Mi, Xiao
    Khan, Muhammad Waseem
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2018, 33 (03) : 3087 - 3096
  • [8] Using Virtual Direct Power Control for synchronizing DFIG with Grid
    Shahroozi, Mohsen
    Ghobadi, Reza
    Radan, Ahmad
    2014 5TH POWER ELECTRONICS, DRIVE SYSTEMS AND TECHNOLOGIES CONFERENCE (PEDSTC), 2014, : 96 - 101
  • [9] Combined Vector Control and Direct Power Control Methods for DFIG under Normal and Unbalanced and Distorted Grid Voltage Conditions
    Zarei, Mohammad Ebrahim
    Asaei, Behzad
    4TH ANNUAL INTERNATIONAL POWER ELECTRONICS, DRIVE SYSTEMS & TECHNOLOGIES CONFERENCE (PEDSTC 2013), 2013, : 107 - 112
  • [10] Resonant Based Backstepping Direct Power Control Strategy for DFIG Under Both Balanced and Unbalanced Grid Conditions
    Wang, Xiaohe
    Sun, Dan
    Zhu, Z. Q.