On-chip laser Doppler vibrometer for arterial pulse wave velocity measurement

被引:41
作者
Li, Yanlu [1 ,2 ]
Segers, Patrick [3 ]
Dirckx, Joris [4 ]
Baets, Roel [1 ,2 ]
机构
[1] Ghent Univ IMEC, INTEC Dept, Photon Res Grp, B-9000 Ghent, Belgium
[2] Univ Ghent, Ctr Nano & Biophoton NB Photon, B-9000 Ghent, Belgium
[3] Univ Ghent, IBiTech bioMMeda, B-9000 Ghent, Belgium
[4] Univ Antwerp, Lab Biomed Phys, B-2020 Antwerp, Belgium
关键词
CAROTID-ARTERY; INSULATOR;
D O I
10.1364/BOE.4.001229
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Pulse wave velocity (PWV) is an important marker for cardiovascular risk. The Laser Doppler vibrometry has been suggested as a potential technique to measure the local carotid PWV by measuring the transit time of the pulse wave between two locations along the common carotid artery (CCA) from skin surface vibrations. However, the present LDV setups are still bulky and difficult to handle. We present in this paper a more compact LDV system integrated on a CMOS-compatible silicon-on-insulator substrate. In this system, a chip with two homodyne LDVs is utilized to simultaneously measure the pulse wave at two different locations along the CCA. Measurement results show that the dual-LDV chip can successfully conduct the PWV measurement. (C) 2013 Optical Society of America
引用
收藏
页码:1229 / 1235
页数:7
相关论文
共 16 条
[1]   Nanophotonic waveguides in silicon-on-insulator fabricated with CMOS technology [J].
Bogaerts, W ;
Baets, R ;
Dumon, P ;
Wiaux, V ;
Beckx, S ;
Taillaert, D ;
Luyssaert, B ;
Van Campenhout, J ;
Bienstman, P ;
Van Thourhout, D .
JOURNAL OF LIGHTWAVE TECHNOLOGY, 2005, 23 (01) :401-412
[2]  
Campbell A., 2011, 2011 5th IEEE International Conference on Self-Adaptive and Self-Organizing Systems (SASO), P119, DOI 10.1109/SASO.2011.23
[3]   Dual-beam laser Doppler vibrometer for measurement of pulse wave velocity in elastic vessels [J].
Campo, Adriaan ;
Dirckx, Joris .
22ND CONGRESS OF THE INTERNATIONAL COMMISSION FOR OPTICS: LIGHT FOR THE DEVELOPMENT OF THE WORLD, 2011, 8011
[4]   Laser diode self-mixing technique for sensing applications [J].
Giuliani, G ;
Norgia, M ;
Donati, S ;
Bosch, T .
JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2002, 4 (06) :S283-S294
[5]   High-performance 90 hybrid based on a silicon-on-insulator multimode interference coupler [J].
Halir, R. ;
Roelkens, G. ;
Ortega-Monux, A. ;
Wangueemert-Perez, J. G. .
OPTICS LETTERS, 2011, 36 (02) :178-180
[6]   Confluence of incident and reflected waves interferes with systolic foot detection of the carotid artery distension waveform [J].
Hermeling, Evelien ;
Reesink, Koen D. ;
Reneman, Robert S. ;
Hoeks, Arnold P. G. .
JOURNAL OF HYPERTENSION, 2008, 26 (12) :2374-2380
[7]   Homodyne laser Doppler vibrometer on silicon-on-insulator with integrated 90 degree optical hybrids [J].
Li, Yanlu ;
Baets, Roel .
OPTICS EXPRESS, 2013, 21 (11) :13342-13350
[8]   Heterodyne laser Doppler vibrometers integrated on silicon-on-insulator based on serrodyne thermo-optic frequency shifters [J].
Li, Yanlu ;
Verstuyft, Steven ;
Yurtsever, Gunay ;
Keyvaninia, Shahram ;
Roelkens, Gunther ;
Van Thourhout, Dries ;
Baets, Roel .
APPLIED OPTICS, 2013, 52 (10) :2145-2152
[9]   Pulse Wave Imaging of the Human Carotid Artery: An In Vivo Feasibility Study [J].
Luo, Jianwen ;
Li, Ronny X. ;
Konofagou, Elisa E. .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2012, 59 (01) :174-181
[10]  
Mancia G, 2007, EUR HEART J, V28, P1462, DOI [10.1093/eurheartj/ehm236, 10.1093/eurheartj/eht151]