Possible factors modifying the surgically induced astigmatism in cataract surgery

被引:10
作者
Storr-Paulsen, A [1 ]
Madsen, H
Perriard, A
机构
[1] Frederiksberg Univ Hosp, Dept Ophthalmol, DK-2200 Frederiksberg, Denmark
[2] Herlev Univ Hosp, Dept Ophthalmol, Herlev, Denmark
来源
ACTA OPHTHALMOLOGICA SCANDINAVICA | 1999年 / 77卷 / 05期
关键词
cataract surgery; surgically induced astigmatism; modifying factors; age; preoperative astigmatism; postoperative IOP;
D O I
10.1034/j.1600-0420.1999.770513.x
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To investigate possible modifiers of the surgically induced astigmatism with special reference to age, gender, preoperative astigmatism, and the intraocular pressure. Methods & patients: Data for one hundred and one cataract patients operated on,vith extracapsular cataract extraction and intraocular lens implantation were prospectively recorded and followed for sis years, Different explanatory variables like age, gender, preoperative astigmatism and postoperative intraocular pressure (IOP) were considered, Astigmatic changes were calculated as Naeser's polar values, Results: The surgically induced astigmatism was not significant at one year, but was significantly increased 3- and 6-years postoperatively. At the same time the keratometric axis made a shift toward against-the-rule astigmatism, The postoperative mean-IOP was lower at all controls, Multiple regression analysis showed that a large preoperative astigmatism, a low postoperative IOP, and high age resulted in more surgically induced astigmatism against-the-rule. Conclusion: The length and the architecture of the incision are known to have an influence on the surgically induced astigmatism in cataract surgery. In the present study we used a multiple regression analysis model to show a significant correlation between the surgically induced astigmatism and age, preoperative astigmatism, and postoperative IOP.
引用
收藏
页码:548 / 551
页数:4
相关论文
共 22 条
[1]  
Clayman, 1975, T AM ACAD OPHTHALMOL, V79, pOP615
[3]  
Dam-Johansen M., 1994, Eur J Implant Refract Surg, V6, P337, DOI [10.1016/S0955-3681(13)80208-0, DOI 10.1016/S0955-3681(13)80208-0]
[4]   ASTIGMATISM AFTER CATARACT-SURGERY - NYLON VERSUS MERSILENE - 5-YEAR DATA [J].
DREWS, RC .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1995, 21 (01) :70-72
[5]  
FLEDELIUS HC, 1984, ACTA OPHTHALMOL, V62, P391
[6]  
FORSIUS H, 1964, ACTA OPHTHALMOL, V42, P224
[7]  
KRONISH JW, 1987, ARCH OPHTHALMOL-CHIC, V105, P1650
[8]   CONVERSION OF KERATOMETER READINGS TO POLAR VALUES [J].
NAESER, K .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1990, 16 (06) :741-745
[9]   SMALL INCISIONS TO CONTROL ASTIGMATISM DURING CATARACT-SURGERY [J].
NEUMANN, AC ;
MCCARTY, GR ;
SANDERS, DR ;
RAANAN, MG .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (01) :78-84
[10]  
Ninn-Pedersen K, 1997, ACTA OPHTHALMOL SCAN, V75, P558