Direct Ion Speciation Analysis with Ion-Selective Membranes Operated in a Sequential Potentiometric/Time Resolved Chronopotentiometric Sensing Mode

被引:38
作者
Afshar, Majid Ghahraman [1 ]
Crespo, Gaston A. [1 ]
Bakker, Eric [1 ]
机构
[1] Univ Geneva, Dept Inorgan & Analyt Chem, CH-1211 Geneva, Switzerland
基金
瑞士国家科学基金会;
关键词
UNIFORM CONCENTRATION PROFILES; CURRENT PULSE METHOD; TOTAL CALCIUM; DETECTION LIMIT; ELECTRODES; RU(BPY)(3)(2+); PARAMETERS; DIFFUSION; TRANSPORT;
D O I
10.1021/ac302092m
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion-selective membranes based on porous polypropylene membranes doped with an ionophore and a lipophilic cation-exchanger are used here in a new tandem measurement mode that combines dynamic electrochemistry and zero current potentiometry into a single protocol. Open circuit potential measurements yield near-Nernstian response slopes in complete analogy to established ion-selective electrode methodology. Such measurements are well established to give direct information on the so-called free ion concentration (strictly, activity) in the sample. The same membrane is here also operated in a constant current mode, in which the localized ion depletion at a transition time is visualized by chronopotentiometry. This dynamic electrochemistry methodology gives information on the labile ion concentration in the sample. The sequential protocol is established on potassium and calcium ion-selective membranes. An increase of the ionophore concentration in the membrane to 180 mM makes it possible to determine calcium concentrations as high as 3 mM by chronopotentiometry, thereby making it possible to directly detect total calcium in undiluted blood samples. Recovery times after current perturbation depend on the current amplitude but can be kept to below 1 min for the polypropylene based ion-selective membranes studied here. Plasticized PVC as membrane material is less suited for this protocol, especially when the measurement at elevated concentrations is desired. An analysis of current amplitudes, transition times, and concentrations shows that the data are described by the Sand equation and that migration effects are insignificant. A numerical model describes the experimental findings with good agreement and gives guidance on the required selectivity in order to observe a well-resolved transition time and on the expected errors due to insufficient selectivity. The simulations suggest that the methodology compares well to that of open circuit potentiometry, despite giving complementary information about the sample. The tandem methodology is demonstrated in a titration of calcium with nitrilotriacetic acid (NTA) and in the direct detection of calcium in undiluted heparinized and citrated blood.
引用
收藏
页码:8813 / 8821
页数:9
相关论文
共 29 条
[1]  
Bakker E, 1999, ELECTROANAL, V11, P1088
[2]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[3]   Advancing Membrane Electrodes and Optical Ion Sensors [J].
Bakker, Eric ;
Crespo, Gaston ;
Grygolowicz-Pawlak, Ewa ;
Mistlberger, Guenter ;
Pawlak, Marcin ;
Xie, Xiaojiang .
CHIMIA, 2011, 65 (03) :141-149
[4]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[5]  
CALI JP, 1973, CLIN CHEM, V19, P1208
[6]   Influence of key parameters on the lower detection limit and response function of solvent polymeric membrane ion-selective electrodes [J].
Ceresa, A ;
Sokalski, T ;
Pretsch, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2001, 501 (1-2) :70-76
[7]   Direct potentiometric information on total ionic concentrations [J].
Ceresa, A ;
Pretsch, E ;
Bakker, E .
ANALYTICAL CHEMISTRY, 2000, 72 (09) :2050-2054
[8]  
Crespo G. A., 2012, ANGEW CHEM INT UNPUB
[9]   Towards Ion-Selective Membranes with Electrogenerated Chemiluminescence Detection: Visualizing Selective Ru(bpy)32+ Transport Across a Plasticized Poly(vinyl chloride) Membrane [J].
Crespo, Gaston A. ;
Mistlberger, Guenter ;
Bakker, Eric .
ELECTROANALYSIS, 2012, 24 (01) :61-68
[10]   Electrogenerated chemiluminescence triggered by electroseparation of Ru(bpy)32+ across a supported liquid membrane [J].
Crespo, Gaston A. ;
Mistlberger, Guenter ;
Bakker, Eric .
CHEMICAL COMMUNICATIONS, 2011, 47 (42) :11644-11646