Screening for diabetic retinopathy using new mydriasis-free, full-field flicker ERG recording device

被引:58
作者
Fukuo, Motonobu [1 ]
Kondo, Mineo [2 ]
Hirose, Akira [1 ]
Fukushima, Harumi [1 ]
Ikesugi, Kengo [2 ]
Sugimoto, Masahiko [2 ]
Kato, Kumiko [2 ]
Uchigata, Yasuko [3 ]
Kitano, Shigehiko [1 ]
机构
[1] Tokyo Womens Med Univ, Ctr Diabet, Dept Diabet Ophthalmol, Tokyo, Japan
[2] Mie Univ, Dept Ophthalmol, Grad Sch Med, Tsu, Mie, Japan
[3] Tokyo Womens Med Univ, Sch Med, Diabet Ctr, Tokyo, Japan
来源
SCIENTIFIC REPORTS | 2016年 / 6卷
关键词
FUNDUS PHOTOGRAPHY; IMPLICIT TIME; ELECTRORETINOGRAM; SYSTEM;
D O I
10.1038/srep36591
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Diabetic retinopathy (DR) is a leading cause of blindness among working-age adults. Therefore, it is important to detect DR accurately during mass screening. The purpose of this study was to determine whether a small, hand-held, mydriasis-free, full-field flicker electroretinographic (ERGs) device called RETeval can be used to screen for DR. To accomplish this, we recorded full-field flicker ERGs with this device from 48 normal eyes and 118 eyes with different severities of DR in patients with diabetes mellitus (DM). This system delivered a constant flash retinal luminance by adjusting the flash luminance that compensated for changes in the pupil size. Our results showed that there were significant correlations between the severity of DR and the implicit times (P < 0.001; r = 0.55) and the amplitudes (P = 0.001; r = -0.29). When the implicit time was used for the index, the area under the receiver operating characteristic curve was 0.84 for the detection of DR, and was 0.89 for the detection of DR requiring ophthalmic treatments. These results suggest that the implicit times of the flicker ERGs recorded by the small, mydryasis-free ERG system can be used as an adjunctive tool to screen for DR.
引用
收藏
页数:8
相关论文
共 37 条
  • [31] The electroretinogram in diabetic retinopathy
    Tzekov, R
    Arden, GB
    [J]. SURVEY OF OPHTHALMOLOGY, 1999, 44 (01) : 53 - 60
  • [32] Oscillatory potentials in the retina: what do they reveal
    Wachtmeister, L
    [J]. PROGRESS IN RETINAL AND EYE RESEARCH, 1998, 17 (04) : 485 - 521
  • [33] Proposed international clinical diabetic retinopathy and diabetic macular edema disease severity scales
    Wilkinson, CP
    Ferris, FL
    Klein, RE
    Lee, PP
    Agardh, CD
    Davis, M
    Dills, D
    Kampik, A
    Pararajasegaram, R
    Verdaguer, JT
    [J]. OPHTHALMOLOGY, 2003, 110 (09) : 1677 - 1682
  • [34] Single-field fundus photography for diabetic retinopathy screening - A report by the American Academy of Ophthalmology
    Williams, GA
    Scott, IU
    Haller, JA
    Maguire, AM
    Marcus, D
    McDonald, HR
    [J]. OPHTHALMOLOGY, 2004, 111 (05) : 1055 - 1062
  • [35] Flicker electroretinograms before and after intravitreal ranibizumab injection in eyes with central retinal vein occlusion
    Yasuda, Shunsuke
    Kachi, Shu
    Ueno, Shinji
    Piao, Chang-Hua
    Terasaki, Hiroko
    [J]. ACTA OPHTHALMOLOGICA, 2015, 93 (06) : E465 - E468
  • [36] Global Prevalence and Major Risk Factors of Diabetic Retinopathy
    Yau, Joanne W. Y.
    Rogers, Sophie L.
    Kawasaki, Ryo
    Lamoureux, Ecosse L.
    Kowalski, Jonathan W.
    Bek, Toke
    Chen, Shih-Jen
    Dekker, Jacqueline M.
    Fletcher, Astrid
    Grauslund, Jakob
    Haffner, Steven
    Hamman, Richard F.
    Ikram, M. Kamran
    Kayama, Takamasa
    Klein, Barbara E. K.
    Klein, Ronald
    Krishnaiah, Sannapaneni
    Mayurasakorn, Korapat
    O'Hare, Joseph P.
    Orchard, Trevor J.
    Porta, Massimo
    Rema, Mohan
    Roy, Monique S.
    Sharma, Tarun
    Shaw, Jonathan
    Taylor, Hugh
    Tielsch, James M.
    Varma, Rohit
    Wang, Jie Jin
    Wang, Ningli
    West, Sheila
    Xu, Liang
    Yasuda, Miho
    Zhang, Xinzhi
    Mitchell, Paul
    Wong, Tien Y.
    [J]. DIABETES CARE, 2012, 35 (03) : 556 - 564
  • [37] YONEMURA D, 1962, ARCH OPHTHALMOL-CHIC, V68, P19