Silent atrial fibrillation in pacemaker early post-implantation period: an unintentionally provoked situation?

被引:7
作者
Benezet-Mazuecos, Juan [1 ]
Antonio Iglesias, Jose [1 ]
Cortes, Marcelino [1 ]
Manuel Rubio, Jose [1 ]
Jose de la Vieja, Juan [1 ]
del Rio, Ana [1 ]
Sanchez-Borque, Pepa [1 ]
Miracle, Angel [1 ]
Farre, Jeronimo [1 ]
机构
[1] Hosp Univ Fdn Jimenez Diaz Quironsalud, Serv Cardiol, Unidad Arritmias, Ave Reyes Catolicos 2, Madrid 28040, Spain
来源
EUROPACE | 2018年 / 20卷 / 05期
关键词
Atrial fibrillation; Pacemaker; Silent ischaemic brain lesions; Atrial high-rate episodes; Atrial lead fixation; HIGH-RATE EPISODES; IMPLANTABLE ELECTRONIC DEVICES; STORED ELECTROGRAMS; STROKE; TRIAL; TACHYARRHYTHMIAS; LEADS;
D O I
10.1093/europace/eux053
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aims Atrial high-rate episodes (AHREs) compatible with silent AF detected in pacemakers (PM) are related to an increased risk of stroke and silent ischaemic brain lesions (IBL) on CT scan. AHREs soon after PM implantation could be related with the procedure itself and the prognosis might be different. Methods and results We analysed the incidence of AHREs >5 min and the presence of silent IBL in 110 patients (56% men, aged 75 +/- 9 year-old) with PM and no history of AF, in relation to time from implantation (<= 3 months vs. > 3 months) and the atrial lead fixation (LF) (active vs. passive). Mean CHADS2 and CHA2DS2VASc scores were 1.9 +/- 1.2 and 3.5 +/- 1.5, respectively. Time from implantation was <= 3 months in 88 patients (80%). Active LF was used in 55 patients (50%). After 24 +/- 9 months, AHREs were present in 40 patients (36.4%). CT-scan showed silent IBL in 26 patients (23.6%). The presence of AHREs at 3 months was more frequent in the patients with recent PM implantation (17% vs. 4.5%, P = 0.09) and significantly related to active LF (OR 5.36, 1.43-20.07; P < 0.05). The presence of silent IBL was related to the detection of AHREs during follow up (OR 3.12, 1.29-7.97; P < 0.05) but not with AHREs at first 3 months (OR 1.58, 0.49-5.05; P = 0.44). Conclusions AHREs occur frequently during the first 3 months after PM implantation and could be related with procedure itself and the use of active LF. AHREs in this period might not be related to worse outcomes and should be interpreted cautiously.
引用
收藏
页码:758 / 763
页数:6
相关论文
共 19 条
[1]   Silent brain infarcts in high blood pressure patients with cardiac implantable electronic devices: unmasking silent atrial fibrillation [J].
Benezet-Mazuecos, Juan ;
Antonio Iglesias, Jose ;
Cortes, Marcelino ;
Jose De La Vieja, Juan ;
Manuel Rubio, Jose ;
Sanchez-Borque, Pepa ;
Farre, Jeronimo .
JOURNAL OF HYPERTENSION, 2016, 34 (02) :338-344
[2]   Silent ischaemic brain lesions related to atrial high rate episodes in patients with cardiac implantable electronic devices [J].
Benezet-Mazuecos, Juan ;
Manuel Rubio, Jose ;
Cortes, Marcelino ;
Antonio Iglesias, Jose ;
Calle, Soraya ;
Jose de la Vieja, Juan ;
Angel Quinones, Miguel ;
Sanchez-Borque, Pepa ;
de la Cruz, Elena ;
Espejo, Adriana ;
Farre, Jeronimo .
EUROPACE, 2015, 17 (03) :364-369
[3]   Preferred tools and techniques for implantation of cardiac electronic devices in Europe: results of the European Heart Rhythm Association survey [J].
Bongiorni, Maria Grazia ;
Proclemer, Alessandro ;
Dobreanu, Dan ;
Marinskis, Germanas ;
Pison, Laurent ;
Blomstrom-Lundqvist, Carina .
EUROPACE, 2013, 15 (11) :1664-1668
[4]   2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy [J].
Brignole, Michele ;
Auricchio, Angelo ;
Baron-Esquivias, Gonzalo ;
Bordachar, Pierre ;
Boriani, Giuseppe ;
Breithardt, Ole-A ;
Cleland, John ;
Deharo, Jean-Claude ;
Delgado, Victoria ;
Elliott, Perry M. ;
Gorenek, Bulent ;
Israel, Carsten W. ;
Leclercq, Christophe ;
Linde, Cecilia ;
Mont, Llus ;
Padeletti, Luigi ;
Sutton, Richard ;
Vardas, Panos E. ;
Zamorano, Jose Luis ;
Achenbach, Stephan ;
Baumgartner, Helmut ;
Bax, Jeroen J. ;
Bueno, Hctor ;
Dean, Veronica ;
Deaton, Christi ;
Erol, Cetin ;
Fagard, Robert ;
Ferrari, Roberto ;
Hasdai, David ;
Hoes, Arno W. ;
Kirchhof, Paulus ;
Knuuti, Juhani ;
Kolh, Philippe ;
Lancellotti, Patrizio ;
Linhart, Ales ;
Nihoyannopoulos, Petros ;
Piepoli, Massimo F. ;
Ponikowski, Piotr ;
Sirnes, Per Anton ;
Tamargo, Juan Luis ;
Tendera, Michal ;
Torbicki, Adam ;
Wijns, William ;
Windecker, Stephan ;
Kirchhof, Paulus ;
Blomstrom-Lundqvist, Carina ;
Badano, Luigi P. ;
Aliyev, Farid ;
Bnsch, Dietmar ;
Baumgartner, Helmut .
EUROPACE, 2013, 15 (08) :1070-1118
[5]   Atrial high-rate episodes and stroke prevention [J].
Camm, A. John ;
Simantirakis, Emmanuel ;
Goette, Andreas ;
Lip, Gregory Y. H. ;
Vardas, Panos ;
Calvert, Melanie ;
Chlouverakis, Gregory ;
Diener, Hans-Christoph ;
Kirchhof, Paulus .
EUROPACE, 2017, 19 (02) :169-179
[6]   Newly detected atrial fibrillation following dual chamber pacemaker implantation [J].
Cheung, Jim W. ;
Keating, Richard J. ;
Stein, Kenneth M. ;
Markowitz, Steven M. ;
Iwai, Sei ;
Shah, Bindi K. ;
Lerman, Bruce B. ;
Mittal, Suneet .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2006, 17 (12) :1323-1328
[7]   SILENT CEREBRAL INFARCTION IN PATIENTS WITH NONRHEUMATIC ATRIAL-FIBRILLATION [J].
EZEKOWITZ, MD ;
JAMES, KE ;
NAZARIAN, SM ;
DAVENPORT, J ;
BRODERICK, JP ;
GUPTA, SR ;
THADANI, V ;
MEYER, ML ;
BRIDGERS, SL .
CIRCULATION, 1995, 92 (08) :2178-2182
[8]   Cryptogenic stroke: Is silent atrial fibrillation the culprit? [J].
Glotzer, Taya V. ;
Ziegler, Paul D. .
HEART RHYTHM, 2015, 12 (01) :234-241
[9]   The Relationship Between Daily Atrial Tachyarrhythmia Burden From Implantable Device Diagnostics and Stroke Risk The TRENDS Study [J].
Glotzer, Taya V. ;
Daoud, Emile G. ;
Wyse, D. George ;
Singer, Daniel E. ;
Ezekowitz, Michael D. ;
Hilker, Christopher ;
Miller, Clayton ;
Qi, Dongfeng ;
Ziegler, Paul D. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (05) :474-480
[10]   Atrial high rate episodes detected by pacemaker diagnostics predict death and stroke - Report of the atrial diagnostics ancillary study of the MOde Selection Trial (MOST) [J].
Glotzer, TV ;
Hellkamp, AS ;
Zimmerman, J ;
Sweeney, MO ;
Yee, R ;
Marinchak, R ;
Cook, J ;
Paraschos, A ;
Love, J ;
Radoslovich, G ;
Lee, KL ;
Lamas, GA .
CIRCULATION, 2003, 107 (12) :1614-1619