Patient-specific hip geometry has greater effect on THA wear than femoral head size

被引:4
作者
Daniel, Matej [1 ]
Rijavec, Boris [2 ]
Dolinar, Drago [3 ]
Pokorny, David [4 ]
Iglic, Ales [5 ]
Kralj-Iglic, Veronika [2 ]
机构
[1] Czech Tech Univ, Fac Mech Engn, Prague, Czech Republic
[2] Univ Ljubljana, Fac Hlth Sci, Lab Clin Biophys, Ljubljana 61000, Slovenia
[3] Univ Med Ctr Ljubljana, Dept Orthopaed Surg, Ljubljana, Slovenia
[4] Charles Univ Prague, Fac Med 1, Prague, Czech Republic
[5] Univ Ljubljana, Fac Elect Engn, Biophys Lab, Ljubljana 61000, Slovenia
关键词
UHMWPE; Linear penetration; Contact pressure; Design; CROSS-LINKED POLYETHYLENE; CEMENTLESS ACETABULAR COMPONENTS; BEARING SURFACES; FOLLOW-UP; CONVENTIONAL POLYETHYLENE; PENETRATION RATES; CONTACT MECHANICS; ARTHROPLASTY; REPLACEMENT; PREDICTION;
D O I
10.1016/j.jbiomech.2016.10.030
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
In vivo linear penetration in total hip arthroplasty (THA) exhibits similar values for 28 mm and 32 mm femoral head diameter with considerable variations between and within the studies. It indicates factors other than femoral head diameter influence polyethylene wear. This study is intended to test the effect of patient's individual geometry of musculoskeletal system, acetabular cup orientation, and radius of femoral head on wear. Variation in patient's musculoskeletal geometry and acetabular cup placement is evaluated in two groups of patients implanted with 28 mm and 32 mm THA heads. Linear wear rate estimated by mathematical model is 0.165-0.185 mm/year and 0.157-0.205 mm/year for 28 and 32 mm THA heads, respectively. Simulations show little influence femoral head size has on the estimated annual wear rate. Predicted annual linear wear depends mostly on the abduction angle of the acetabular cup and individual geometry of the musculoskeletal system of the hip, with the latter having the greatest affect on variation in linear wear rate. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:3996 / 4001
页数:6
相关论文
共 60 条
[31]   The effect of geometry and abduction angle on the stresses in cemented UHMWPE acetabular cups - finite element simulations and experimental tests [J].
Korhonen, Rami K. ;
Koistinen, Arto ;
Konttinen, Yrjo T. ;
Santavirta, Seppo S. ;
Lappalainen, Reijo .
BIOMEDICAL ENGINEERING ONLINE, 2005, 4 (1)
[32]   Polyethylene Wear is Related to Patient-specific Contact Stress in THA [J].
Kosak, Robert ;
Kralj-Iglic, Veronika ;
Iglic, Ales ;
Daniel, Matej .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2011, 469 (12) :3415-3422
[33]   Femoral Head Size and Wear of Highly Cross-linked Polyethylene at 5 to 8 Years [J].
Lachiewicz, Paul F. ;
Heckman, Daniel S. ;
Soileau, Elizabeth S. ;
Mangla, Jimmi ;
Martell, John M. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (12) :3290-3296
[34]   Early polyethylene wear and osteolysis in cementless total hip arthroplasty - The influence of femoral head size and polyethylene thickness [J].
Lee, PC ;
Shih, CH ;
Chen, WJ ;
Tu, YK ;
Tai, CL .
JOURNAL OF ARTHROPLASTY, 1999, 14 (08) :976-981
[35]   Acetabular Polyethylene Wear and Acetabular Inclination and Femoral Offset [J].
Little, Nick J. ;
Busch, Constant A. ;
Gallagher, John A. ;
Rorabeck, Cecil H. ;
Bourne, Robert B. .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2009, 467 (11) :2895-2900
[36]   A new formulation for the prediction of polyethylene wear in artificial hip joints [J].
Liu, F. ;
Galvin, A. ;
Jin, Z. ;
Fisher, J. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H1) :16-24
[37]   Effect of motion inputs on the wear prediction of artificial hip joints [J].
Liu, Feng ;
Fisher, John ;
Jin, Zhongmin .
TRIBOLOGY INTERNATIONAL, 2013, 63 :105-114
[38]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528
[39]   Clinical performance of a highly cross-linked polyethylene at two years in total hip arthroplasty: A randomized prospective trial [J].
Martell, JM ;
Verner, JJ ;
Incavo, SJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (07) :55-59
[40]   Lubrication and wear modelling of artificial hip joints: A review [J].
Mattei, L. ;
Di Puccio, F. ;
Piccigallo, B. ;
Ciulli, E. .
TRIBOLOGY INTERNATIONAL, 2011, 44 (05) :532-549