Regional Mapping of Gas Uptake by Blood and Tissue in the Human Lung Using Hyperpolarized Xenon-129 MRI

被引:148
作者
Qing, Kun [1 ]
Ruppert, Kai [2 ]
Jiang, Yun [3 ]
Mata, Jaime F. [2 ]
Miller, Wilson [2 ]
Shim, Y. Michael [4 ]
Wang, Chengbo [2 ]
Ruset, Iulian C. [5 ,6 ]
Hersman, F. William [5 ,6 ]
Altes, Talissa A. [2 ]
Mugler, John P., III [1 ,2 ]
机构
[1] Univ Virginia, Sch Med, Dept Biomed Engn, Charlottesville, VA 22908 USA
[2] Univ Virginia, Sch Med, Dept Radiol & Med Imaging, Ctr In Vivo Hyperpolarized Gas MR Imaging, Charlottesville, VA 22908 USA
[3] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[4] Univ Virginia, Sch Med, Dept Med Pulm & Crit Care, Charlottesville, VA 22908 USA
[5] Xemed LLC, Durham, NH USA
[6] Univ New Hampshire, Dept Phys, Durham, NH 03824 USA
关键词
lung imaging; pulmonary disease; gas uptake; hyperpolarized xenon-129; NUCLEAR-MAGNETIC-RESONANCE; WATER-FAT DECOMPOSITION; LASER-POLARIZED XE-129; DIFFUSING-CAPACITY; BREATH-HOLD; RAT LUNG; IN-VIVO; RECONSTRUCTION; SPECTROSCOPY; DYNAMICS;
D O I
10.1002/jmri.24181
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeTo develop a breathhold acquisition for regional mapping of ventilation and the fractions of hyperpolarized xenon-129 (Xe129) dissolved in tissue (lung parenchyma and plasma) and red blood cells (RBCs), and to perform an exploratory study to characterize data obtained in human subjects. Materials and MethodsA three-dimensional, multi-echo, radial-trajectory pulse sequence was developed to obtain ventilation (gaseous Xe129), tissue, and RBC images in healthy subjects, smokers, and asthmatics. Signal ratios (total dissolved Xe129 to gas, tissue-to-gas, RBC-to-gas, and RBC-to-tissue) were calculated from the images for quantitative comparison. ResultsHealthy subjects demonstrated generally uniform values within coronal slices, and a gradient in values along the anterior-to-posterior direction. In contrast, images and associated ratio maps in smokers and asthmatics were generally heterogeneous and exhibited values mostly lower than those in healthy subjects. Whole-lung values of total dissolved Xe129 to gas, tissue-to-gas, and RBC-to-gas ratios in healthy subjects were significantly larger than those in diseased subjects. ConclusionRegional maps of tissue and RBC fractions of dissolved Xe129 were obtained from a short breathhold acquisition, well tolerated by healthy volunteers and subjects with obstructive lung disease. Marked differences were observed in spatial distributions and overall amounts of Xe129 dissolved in tissue and RBCs among healthy subjects, smokers and asthmatics. J. Magn. Reson. Imaging 2014;39:346-359. (c) 2013 Wiley Periodicals, Inc.
引用
收藏
页码:346 / 359
页数:14
相关论文
共 37 条
  • [21] Pulmonary ventilation visualized using hyperpolarized helium-3 and xenon-129 magnetic resonance imaging: differences in COPD and relationship to emphysema
    Kirby, Miranda
    Svenningsen, Sarah
    Kanhere, Nikhil
    Owrangi, Amir
    Wheatley, Andrew
    Coxson, Harvey O.
    Santyr, Giles E.
    Paterson, Nigel A. M.
    McCormack, David G.
    Parraga, Grace
    JOURNAL OF APPLIED PHYSIOLOGY, 2013, 114 (06) : 707 - 715
  • [22] Hyperpolarized 129Xe MRI of the mouse lung at a low xenon concentration using a continuous flow-type hyperpolarizing system
    Wakayama, Tetsuya
    Kitamoto, Masakazu
    Ueyama, Tsuyoshi
    Imai, Hirohiko
    Narazaki, Michiko
    Kimura, Atsuomi
    Fujiwara, Hideaki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2008, 27 (04) : 777 - 784
  • [23] Imaging gas-exchange lung function and brain tissue uptake of hyperpolarized 129Xe using sampling density-weighted MRSI
    Collier, Guilhem J.
    Schulte, Rolf F.
    Rao, Madhwesha
    Norquay, Graham
    Ball, James
    Wild, Jim M.
    MAGNETIC RESONANCE IN MEDICINE, 2023, 89 (06) : 2217 - 2226
  • [24] Quantification of regional early stage gas exchange changes using hyperpolarized 129Xe MRI in a rat model of radiation-induced lung injury
    Doganay, Ozkan
    Stirrat, Elaine
    McKenzie, Charles
    Schulte, Rolf F.
    Santyr, Giles E.
    MEDICAL PHYSICS, 2016, 43 (05) : 2410 - 2420
  • [25] Physiological gas exchange mapping of hyperpolarized 129Xe using spiral-IDEAL and MOXE in a model of regional radiation-induced lung injury
    Zanette, Brandon
    Stirrat, Elaine
    Jelveh, Salomeh
    Hope, Andrew
    Santyr, Giles
    MEDICAL PHYSICS, 2018, 45 (02) : 803 - 816
  • [26] Mapping of regional lung microstructural parameters using hyperpolarized 129Xe dissolved-phase MRI in healthy volunteers and patients with chronic obstructive pulmonary disease
    Kern, Agilo L.
    Gutberlet, Marcel
    Voskrebenzev, Andreas
    Klimes, Filip
    Rotaermel, Alexander
    Wacker, Frank
    Hohlfeld, Jens M.
    Vogel-Claussen, Jens
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (04) : 2360 - 2373
  • [27] Imaging alveolar-capillary gas transfer using hyperpolarized 129Xe MRI
    Driehuys, Bastiaan
    Cofer, Gary P.
    Pollaro, Jim
    Mackel, Julie Boslego
    Hedlund, Laurence W.
    Johnson, G. Allan
    PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2006, 103 (48) : 18278 - 18283
  • [28] Measurement of xenon diffusing capacity in the rat lung by hyperpolarized 129Xe MRI and dynamic spectroscopy in a single breath-hold
    Abdeen, Nishard
    Cross, Albert
    Cron, Gregory
    White, Steven
    Rand, Thomas
    Miller, David
    Santyr, Giles
    MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (02) : 255 - 264
  • [29] Regional variations in hyperpolarized 129Xe lung MRI: Insights from CSI-CSSR and CSSR in healthy and irradiated rat models
    Ruppert, Kai
    Loza, Luis
    Hamedani, Hooman
    Ismail, Mostafa
    Chen, Jiawei
    Duncan, Ian F.
    Profka, Harrilla
    Kadlecek, Stephen
    Rizi, Rahim R.
    MAGNETIC RESONANCE IN MEDICINE, 2025, 93 (03) : 902 - 915
  • [30] Simultaneous assessment of both lung morphometry and gas exchange function within a single breath-hold by hyperpolarized 129Xe MRI
    Zhong, Jianping
    Zhang, Huiting
    Ruan, Weiwei
    Xie, Junshuai
    Li, Haidong
    Deng, He
    Han, Yeqing
    Sun, Xianping
    Ye, Chaohui
    Zhou, Xin
    NMR IN BIOMEDICINE, 2017, 30 (08)