Assessment of Circumferential Angle-Closure by the IriseTrabecular Contact Index with Swept-Source Optical Coherence Tomography

被引:53
作者
Baskaran, Mani [1 ,2 ,3 ]
Ho, Sue-Wei [1 ,2 ]
Tun, Tin A. [1 ,2 ]
How, Alicia C. [1 ,2 ]
Perera, Shamira A. [1 ,2 ]
Friedman, David S. [4 ,5 ]
Aung, Tin [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[4] Johns Hopkins Univ Hosp, Wilmer Ophthalmol Inst, Dana Ctr Prevent Ophthalmol, Wilmer Eye Inst, Baltimore, MD 21205 USA
[5] Johns Hopkins Bloomberg Sch Publ Hlth, Baltimore, MD USA
关键词
ANTERIOR-CHAMBER ANGLE; SEGMENT; GLAUCOMA; GONIOSCOPY;
D O I
10.1016/j.ophtha.2013.04.020
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the diagnostic performance of the irisetrabecular contact (ITC) index, a measure of the degree of angle-closure, using swept-source optical coherence tomography (SSOCT, CASIA SS-1000, Tomey Corporation, Nagoya, Japan) in comparison with gonioscopy. Design: Prospective observational study. Participants: A total of 108 normal subjects and 32 subjects with angle-closure. Methods: The SSOCT 3-dimensional angle scans, which obtain radial scans for the entire circumference of the angle, were performed under dark conditions and analyzed using customized software by a single examiner masked to the subjects' clinical details. The ITC index was calculated as a percentage of the angle that was closed on SSOCT images. First-order agreement coefficient (AC1) statistics and area under the receiver operating characteristic curve (AUC) analyses were performed for angle-closure on the basis of the ITC index in comparison with gonioscopy. Main Outcome Measures: Angle-closure on gonioscopy was defined as nonvisibility of posterior trabecular meshwork for at least 2 quadrants. Agreement of the ITC index with gonioscopically defined angle-closure was assessed using the AC1 statistic. Results: Study subjects were predominantly Chinese (95.7%) and female (70.7%), with a mean age of 59.2 (standard deviation, 8.9) years. The median ITC index was 15.24% for gonioscopically open-angle eyes (n 108) and 48.5% for closed-angle eyes (n 32) (P 0.0001). The agreement for angle-closure based on ITC index cutoffs (> 35% and >= 50%) and gonioscopic angle-closure was 0.699 and 0.718, respectively. The AUC for angleclosure detection using the ITC index was 0.83 (95% confidence interval, 0.76-0.89), with an ITC index > 35% having a sensitivity of 71.9% and specificity of 84.3%. Conclusions: The ITC index is a summary measure of the circumferential extent of angle-closure as imaged with SSOCT. The index had moderate agreement and good diagnostic performance for angle-closure with gonioscopy as the reference standard.
引用
收藏
页码:2226 / 2231
页数:6
相关论文
共 18 条
[1]  
Chan Y H, 2003, Singapore Med J, V44, P614
[2]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[3]   Glaucoma in Mongolia - A population-based survey in Hovsgol Province, Northern Mongolia [J].
Foster, PJ ;
Baasanhu, J ;
Alsbirk, PH ;
Munkhbayar, D ;
Uranchimeg, D ;
Johnson, GJ .
ARCHIVES OF OPHTHALMOLOGY, 1996, 114 (10) :1235-1241
[4]   Anterior chamber angle assessment techniques [J].
Friedman, David S. ;
He, Mingguang .
SURVEY OF OPHTHALMOLOGY, 2008, 53 (03) :250-273
[5]   Noninvasive Observations of Peripheral Angle in Eyes After Penetrating Keratoplasty Using Anterior Segment Fourier-Domain Optical Coherence Tomography [J].
Fukuda, Reina ;
Usui, Tomohiko ;
Tomidokoro, Atsuo ;
Mishima, Koichi ;
Matagi, Naomi ;
Miyai, Takashi ;
Amano, Shiro ;
Araie, Makoto .
CORNEA, 2012, 31 (03) :259-263
[6]  
GWET K, 2003, HDB INTERWATER RELIA, P309
[7]   Swept source optical coherence tomography measurement of the iris-trabecular contact (ITC) index: a new parameter for angle closure [J].
Ho, Sue-Wei ;
Baskaran, Mani ;
Zheng, Ce ;
Tun, Tin A. ;
Perera, Shamira A. ;
Narayanaswamy, Arun K. ;
Friedman, David S. ;
Aung, Tin .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 251 (04) :1205-1211
[8]  
HOSKINS HD, 1972, INVEST OPHTH VISUAL, V11, P97
[9]   Anterior Chamber Angle Imaging with Swept-Source Optical Coherence Tomography: An Investigation on Variability of Angle Measurement [J].
Liu, Shu ;
Yu, Marco ;
Ye, Cong ;
Lam, Dennis S. C. ;
Leung, Christopher Kai-shun .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2011, 52 (12) :8598-8603
[10]   Anterior segment imaging: ultrasound biomicroscopy and anterior segment optical coherence tomography [J].
Nolan, Winifred .
CURRENT OPINION IN OPHTHALMOLOGY, 2008, 19 (02) :115-121