A NEW PHYSICS-BASED MISFIRE DETECTION TECHNIQUE FOR A SI ENGINE

被引:0
作者
Boudaghi, M. Kh N. [1 ]
Shahbakhti, M. [2 ]
Jazayeri, S. A. [1 ]
机构
[1] KN Toosi Univ Tech, Dept Mech Engn, Tehran, Iran
[2] Michigan Tech Univ, Dept Mech Engn Engn Mech, Houghton, MI USA
来源
PROCEEDINGS OF THE ASME INTERNAL COMBUSTION ENGINE DIVISION FALL TECHNICAL CONFERENCE, 2013, VOL 1: LARGE BORE ENGINES; ADVANCED COMBUSTION; EMISSIONS CONTROL SYSTEMS; INSTRUMENTATION, CONTROLS, AND HYBRIDS | 2013年
关键词
PRESSURE; GAS;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Control and detection of misfire is an essential part of on-board diagnosis of modern SI engines. This study proposes a novel model-based technique for misfire detection of a multi-cylinder SI engine. The new technique uses a dynamic engine model to determine mean output power, which is then used to calculate a new parameter for misfire detection. The new parameter directly relates to combustion period and is sensitive to the engine speed fluctuations caused by misfire. The new technique only requires measured engine speed data and it is computationally viable for use in a typical ECU. The new technique is evaluated experimentally on a 4-cylinder 1.6-liter SI engine. Three types of misfires are studied including single, continues, and multiple events. The steady-state and transient experiments were done for a wide range of engine speeds and engine loads, using a vehicle chassis dynamometer and on-road vehicle testing. The validation results show the new technique is capable to detect all the three types of misfire with up to 97 percent accuracy during steady-state conditions. The new technique is augmented with a compensation factor to improve the accuracy of the technique for transient operations. The resulting technique is shown to be capable of detecting misfire during both transient and steady-state engine conditions.
引用
收藏
页数:12
相关论文
共 36 条
[21]   A NEW HBT-BASED FLUORESCENT PROBE FOR HYDRAZINE DETECTION IN AQUEOUS SOLUTION [J].
Dong, Jing-Hua ;
Deng, Jia ;
Zhang, Yuan .
HETEROCYCLES, 2018, 96 (10) :1750-1758
[22]   Room temperature detection of NO2 gas using optical sensor based on surface plasmon resonance technique [J].
Paliwal, Ayushi ;
Sharma, Anjali ;
Tomar, Monika ;
Gupta, Vinay .
SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 :497-503
[23]   Surface acoustic wave sensors with carbon nanotubes and SiO2/Si nanoparticles based nanocomposites for VOC detection [J].
Viespe, Cristian ;
Grigoriu, Constantin .
SENSORS AND ACTUATORS B-CHEMICAL, 2010, 147 (01) :43-47
[24]   Performance analysis of a new precooled engine cycle based on the combined pre-compressor cooling with mass injection and heat exchanger [J].
Zhang, Lelin ;
Wang, Cong ;
Yan, Peigang ;
Fang, Jiwei ;
Xiu, Xinyan ;
Qin, Jiang ;
Xu, Jie .
ENERGY CONVERSION AND MANAGEMENT, 2024, 322
[25]   A new fracture detection method based on full-azimuth anisotropic migration and shaping regularization [J].
Xu, Kai ;
Sun, Zandong .
JOURNAL OF GEOPHYSICS AND ENGINEERING, 2018, 15 (04) :1624-1637
[26]   Hydrogen-natural gas combustion in a marine lean-burn SI engine: A comparitive analysis of Seiliger and double Wiebe function-based zero dimensional modelling [J].
Sapra, Harsh ;
Godjevac, Milinko ;
De Vos, Peter ;
Van Sluijs, Wim ;
Linden, Youri ;
Visser, Klaas .
ENERGY CONVERSION AND MANAGEMENT, 2020, 207
[27]   Damage mechanism analysis of polymer gel to petroleum reservoirs and development of new protective methods based on NMR technique [J].
Zhu, Dao-Yi ;
Zhang, Jiong ;
Zhang, Tao ;
Gao, Ying-Qi ;
Guo, Si ;
Yang, Yong-Liang ;
Lu, Jia-Mai .
PETROLEUM SCIENCE, 2025, 22 (03) :1225-1233
[28]   Application of fiber loop ringdown spectroscopy technique for a new approach to beta-amyloid monitoring for Alzheimer Disease's early detection [J].
Kaya, Burak Malik ;
Oz, Semih ;
Esenturk, Okan .
BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2024, 10 (03)
[29]   Nanostructured Cu/Zn/Al-based oxide as a new sensing material for NO2 detection [J].
Di Francia, Elisabetta ;
Guzman, Hilmar ;
Pugliese, Diego ;
Hernandez, Simelys ;
Tulliani, Jean-Marc .
SENSORS AND ACTUATORS B-CHEMICAL, 2024, 420
[30]   Comparison between multi-channel LDV and PWI for measurement of pulse wave velocity in distensible tubes: Towards a new diagnostic technique for detection of arteriosclerosis [J].
Campo, Adriaan ;
Dudzik, Grzegorz ;
Apostolakis, Jason ;
Waz, Adam ;
Nauleau, Pierre ;
Abramski, Krzysztof ;
Dirckx, Joris ;
Konofagou, Elisa .
OPTICS AND LASERS IN ENGINEERING, 2017, 97 :41-51