Correcting for Spectral Cross-Talk in Dual-Color Fluorescence Cross-Correlation Spectroscopy

被引:37
作者
Bacia, Kirsten [1 ]
Petrasek, Zdenek [2 ]
Schwille, Petra [2 ]
机构
[1] Univ Halle Wittenberg, HALOmem, D-06120 Halle, Germany
[2] Tech Univ Dresden, Inst Biophys, BIOTEC, D-01307 Dresden, Germany
关键词
binding analysis; biophysics; fluorescence; fluorescence correlation spectroscopy; fluorescence spectroscopy; LIVE CELLS; LIVING CELLS; IN-VIVO; KINASE; EXCITATION; BINDING; SITU;
D O I
10.1002/cphc.201100801
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Dual-color fluorescence cross-correlation spectroscopy (dcFCCS) allows one to quantitatively assess the interactions of mobile molecules labeled with distinct fluorophores. The technique is widely applied to both reconstituted and live-cell biological systems. A major drawback of dcFCCS is the risk of an artifactual false-positive or overestimated cross-correlation amplitude arising from spectral cross-talk. Cross-talk can be reduced or prevented by fast alternating excitation, but the technology is not easily implemented in standard commercial setups. An experimental strategy is devised that does not require specialized hardware and software for recognizing and correcting for cross-talk in standard dcFCCS. The dependence of the cross-talk on particle concentrations and brightnesses is quantitatively confirmed. Moreover, it is straightforward to quantitatively correct for cross-talk using quickly accessible parameters, that is, the measured (apparent) fluorescence count rates and correlation amplitudes. Only the bleed-through ratio needs to be determined in a calibration measurement. Finally, the limitations of cross-talk correction and its influence on experimental error are explored.
引用
收藏
页码:1221 / 1231
页数:11
相关论文
共 32 条
[1]   Fluorescence cross-correlation spectroscopy in living cells [J].
Bacia, K ;
Kim, SA ;
Schwille, P .
NATURE METHODS, 2006, 3 (02) :83-89
[2]  
Bacia K., 2010, FLUORESCENCE CORRELA, P609
[3]   Practical guidelines for dual-color fluorescence cross-correlation spectroscopy [J].
Bacia, Kirsten ;
Schwille, Petra .
NATURE PROTOCOLS, 2007, 2 (11) :2842-2856
[4]   Time-resolved fluorescence correlation spectroscopy [J].
Böhmer, M ;
Wahl, M ;
Rahn, HJ ;
Erdmann, R ;
Enderlein, J .
CHEMICAL PHYSICS LETTERS, 2002, 353 (5-6) :439-445
[5]   Fluorescence correlation spectroscopy: linking molecular dynamics to biological function in vitro and in situ [J].
Fitzpatrick, James A. J. ;
Lillemeier, Bjoern F. .
CURRENT OPINION IN STRUCTURAL BIOLOGY, 2011, 21 (05) :650-660
[6]   How the molecule number is correctly quantified in two-color fluorescence cross-correlation spectroscopy:: Corrections for cross-talk and quenching in experiments [J].
Földes-Papp, Z .
CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2005, 6 (06) :437-444
[7]   Simultaneous two-photon excitation of distinct labels for dual-color fluorescence crosscorrelation analysis [J].
Heinze, KG ;
Koltermann, A ;
Schwille, P .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2000, 97 (19) :10377-10382
[8]  
Hink MA, 2011, METHODS MOL BIOL, V779, P199, DOI 10.1007/978-1-61779-264-9_11
[9]   Nuclear Import and Assembly of Influenza A Virus RNA Polymerase Studied in Live Cells by Fluorescence Cross-Correlation Spectroscopy [J].
Huet, Sebastien ;
Avilov, Sergiy V. ;
Ferbitz, Lars ;
Daigle, Nathalie ;
Cusack, Stephen ;
Ellenberg, Jan .
JOURNAL OF VIROLOGY, 2010, 84 (03) :1254-1264
[10]   Single wavelength excitation fluorescence cross-correlation spectroscopy with spectrally similar fluorophores: Resolution for binding studies [J].
Hwang, LC ;
Wohland, T .
JOURNAL OF CHEMICAL PHYSICS, 2005, 122 (11)