Variable-focus Liquid Lens Based on a Laterally-integrated Thermopneumatic Actuator

被引:20
作者
Lee, June Kyoo [1 ]
Park, Kyung-Woo [1 ]
Lim, Geunbae [3 ]
Kim, Hak-Rin [1 ,2 ]
Kong, Seong Ho [1 ,2 ]
机构
[1] Kyungpook Natl Univ, Grad Sch Elect Engn & Comp Sci, Taegu 702701, South Korea
[2] Kyungpook Natl Univ, Sch Elect Engn, Taegu 702701, South Korea
[3] Pohang Univ Sci & Technol, Dept Mech Engn, Pohang 790784, South Korea
基金
新加坡国家研究基金会;
关键词
Variable-focus; Liquid lens; Thermopneumatic actuator; Elastomeric diaphragm; CRYSTAL LENSES; FOCAL LENGTH; MICROLENS; PICKUP;
D O I
10.3807/JOSK.2012.16.1.022
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We report a focal-length tunable liquid lens based on thermopneumatically driven fluidic pressure. The fluidic pressure is generated by deformation of an elastomeric diaphragm induced by thermopneumaticity from a laterally integrated microheater sealed within an air chamber. The pressure is transmitted by a confined liquid to a lens diaphragm through an internal fluid channel. The liquid filling under the lens diaphragm functions as a liquid lens for dynamic focusing with properties depending on the curvature of the deformed diaphragm. The diaphragm area of the air chamber is designed five times larger than that of the lens cavity to yield high focal-length tunability by amplified deflection of the lens diaphragm. With our method, we achieved excellent focal-length tunability from infinity (without an input current) to 4 mm (with an input current of 12 mA) with a lens aperture diameter of 2 mm.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 30 条
[11]   Electrostatic-force-modulated microaspherical lens for optical pickup head [J].
Hung, Kuo-Yung ;
Tseng, Fan-Gang ;
Liao, Tsung-Hsin .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (02) :370-380
[12]   Electrowetting for Tunable Microoptics [J].
Krogmann, Florian ;
Moench, Wolfgang ;
Zappe, Hans .
JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2008, 17 (06) :1501-1512
[13]   Image-processing Based Panoramic Camera Employing Single Fisheye Lens [J].
Kweon, Gyeong-il ;
Choi, Young-ho .
JOURNAL OF THE OPTICAL SOCIETY OF KOREA, 2010, 14 (03) :245-259
[14]   Solvent compatibility of poly(dimethylsiloxane)-based microfluidic devices [J].
Lee, JN ;
Park, C ;
Whitesides, GM .
ANALYTICAL CHEMISTRY, 2003, 75 (23) :6544-6554
[15]   Durability Enhancement of a Microelectromechanical System-Based Liquid Droplet Lens [J].
Lee, June Kyoo ;
Park, Kyung-Woo ;
Kim, Hak-Rin ;
Kong, Seong Ho .
JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (06) :06GN111-06GN115
[16]   Focal tunable liquid lens integrated with an electromagnetic actuator [J].
Lee, Seok Woo ;
Lee, Seung S. .
APPLIED PHYSICS LETTERS, 2007, 90 (12)
[17]   Two Liquids Wetting and Low Hysteresis Electrowetting on Dielectric Applications [J].
Maillard, Mathieu ;
Legrand, Julien ;
Berge, Bruno .
LANGMUIR, 2009, 25 (11) :6162-6167
[18]   Tunable liquid microlens arrays in electrode-less configuration and their accurate characterization by interference microscopy [J].
Miccio, L. ;
Finizio, A. ;
Grilli, S. ;
Vespini, V. ;
Paturzo, M. ;
De Nicola, S. ;
Ferraro, Pietro .
OPTICS EXPRESS, 2009, 17 (04) :2487-2499
[19]   Fluidic lenses with variable focal length [J].
Moran, PM ;
Dharmatilleke, S ;
Khaw, AH ;
Tan, KW ;
Chan, ML ;
Rodriguez, I .
APPLIED PHYSICS LETTERS, 2006, 88 (04) :1-3
[20]   Control optimization of spherical modal liquid crystal lenses [J].
Naumov, AF ;
Love, GD ;
Loktev, MY ;
Vladimirov, FL .
OPTICS EXPRESS, 1999, 4 (09) :344-352