A practical method to improve phasor and power measurement accuracy of DFT algorithm

被引:76
作者
Wang, MH [1 ]
Sun, YZ [1 ]
机构
[1] Tsing Hua Univ, Dept Elect Engn, State Key Lab Power Syst, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
amplitude estimation; discrete Fourier transforms (DFTs); frequency measurement; phase measurement; power measurement;
D O I
10.1109/TPWRD.2005.858769
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Centralized control, which can overcome the ill interactional effects among decentralized controllers, impels a real need for fast and reliable computational algorithms to improve the accuracy of phasor and power measurements. This paper deals with discrete Fourier transform (DFT)-based measurement techniques. Based on the practical frequency tracking method proposed by the same authors in another paper, this paper develops practical compensation method to improve the phasor and power measurement accuracy of the DFT algorithm. The method proposed by this paper takes full advantage of the DFT algorithm. It simply modifies the DFT results. With notable accuracy improvement, the calculation burden of the proposed method is little more than the DFT algorithm. The method can be used for on-line purposes. Though the analog signal studied in this paper is sinusoidal signal, the method proposed by this paper has good performance in the presence of harmonics. Some examples are given to demonstrate the feasibility, simpleness and robustness of the proposed method.
引用
收藏
页码:1054 / 1062
页数:9
相关论文
共 16 条
[1]   WINDOWS AND INTERPOLATION ALGORITHMS TO IMPROVE ELECTRICAL MEASUREMENT ACCURACY [J].
ANDRIA, G ;
SAVINO, M ;
TROTTA, A .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (04) :856-863
[2]   FREQUENCY TRACKING IN POWER NETWORKS IN THE PRESENCE OF HARMONICS [J].
BEGOVIC, MM ;
DJURIC, PM ;
DUNLAP, S ;
PHADKE, AG .
IEEE TRANSACTIONS ON POWER DELIVERY, 1993, 8 (02) :480-486
[3]   AN ADAPTIVE SAMPLING-INTERVAL GENERATOR FOR DIGITAL RELAYING [J].
BENMOUYAL, G .
IEEE TRANSACTIONS ON POWER DELIVERY, 1989, 4 (03) :1602-1609
[4]   Wide-area measurement-based stabilizing control of power system considering signal transmission delay [J].
Chaudhuri, B ;
Majumder, R ;
Pal, BC .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (04) :1971-1979
[5]   Robust damping of multiple swing modes employing global stabilizing signals with a TCSC [J].
Chaudhuri, B ;
Pal, BC .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2004, 19 (01) :499-506
[7]   A new frequency tracking and phasor estimation algorithm for generator protection [J].
Hart, D ;
Novosel, D ;
Hu, Y ;
Smith, B ;
Egolf, M .
IEEE TRANSACTIONS ON POWER DELIVERY, 1997, 12 (03) :1064-1073
[8]   HIGH-ACCURACY ANALOG MEASUREMENTS VIA INTERPOLATED FFT [J].
JAIN, VK ;
COLLINS, WL ;
DAVIS, DC .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1979, 28 (02) :113-122
[9]  
Kamwa I, 1998, P AMER CONTR CONF, P2963, DOI 10.1109/ACC.1998.688401
[10]   Wide-area measurement based stabilizing control of large power systems -: A decentralized/hierarchical approach [J].
Kamwa, I ;
Grondin, R ;
Hébert, Y .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2001, 16 (01) :136-153