D-dimer Simple Test, Tough Problems

被引:49
作者
Olson, John D. [1 ]
Cunningham, Mark T. [2 ]
Higgins, Russell A. [1 ]
Eby, Charles S. [3 ]
Brandt, John T.
机构
[1] Univ Texas Hlth Sci Ctr San Antonio, Dept Pathol, San Antonio, TX 78229 USA
[2] Univ Kansas, Dept Pathol, Med Ctr, Kansas City, MO USA
[3] Washington Univ, Sch Med, Dept Pathol & Immunol, St Louis, MO USA
关键词
DISSEMINATED INTRAVASCULAR COAGULATION; VENOUS THROMBOEMBOLISM; MONOCLONAL-ANTIBODIES; DEGRADATION PRODUCTS; CROSSLINKED FIBRIN; PLASMA; HARMONIZATION; ASSAYS; STANDARDIZATION; PERFORMANCE;
D O I
10.5858/arpa.2012-0296-CP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-D-dimer is widely used for exclusion, or as an aid in diagnosis, of venous thromboembolism (VTE); however, the D-dimer assay methods available from manufacturers and the laboratory application of those methods vary widely. Objective.-To describe the current laboratory practice regarding the assay and reporting of D-dimer. Design.-Laboratories' D-dimer proficiency testing data were analyzed and laboratory practices regarding the performance and reporting of D-dimer were surveyed. Results.-Initial grading of D-dimer proficiency testing demonstrated high variability within and among methods. This variability continued to be present for several years after attempts to intervene. The number of laboratories using D-dimer to exclude VTE grew from 1500 in 2004 to more than 3500 in 2012. Survey and proficiency testing data demonstrated that 33% of laboratories changed the type or magnitude of units from that recommended by the manufacturer, a practice associated with as much as a 20-fold increase in the failure of proficiency testing. Many laboratories used a threshold for the exclusion of VTE that is higher than that recommended by the manufacturer. Many laboratories continue to use qualitative assays with insufficient sensitivity for exclusion of VTE. Conclusions.-There is considerable variability both within and among quantitative methods used to assay D-dimer by laboratories. Laboratory practice continues to vary widely regarding the type and magnitude of units reported and the setting of the threshold for the exclusion of VTE. Although improved, the variability continues despite initial efforts to intervene.
引用
收藏
页码:1030 / 1038
页数:9
相关论文
共 26 条
[21]  
Pfitzner SA, 1997, THROMB HAEMOSTASIS, V78, P1069
[22]   The performance of quantitative D-dimer assays in laboratory routine [J].
Spannagl, M ;
Haverkate, F ;
Reinauer, H ;
Meijer, P .
BLOOD COAGULATION & FIBRINOLYSIS, 2005, 16 (06) :439-443
[23]   Sample size for positive and negative predictive value in diagnostic research using case-control designs [J].
Steinberg, David M. ;
Fine, Jason ;
Chappell, Rick .
BIOSTATISTICS, 2009, 10 (01) :94-105
[24]   The scoring system of the scientific and standardisation committee on disseminated intravascular coagulation of the International Society on Thrombosis and Haemostasis: A 5-year overview [J].
Toh, C. H. ;
Hoots, W. K. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (03) :604-606
[25]   Performance of quantitative D-dimer methods: results of the Italian external quality assessment scheme [J].
Tripodi, A. ;
Chantarangkul, V. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2007, 5 (01) :184-185
[26]   MEASUREMENT OF CROSS-LINKED FIBRIN DERIVATIVES IN PLASMA - AN IMMUNOASSAY USING MONOCLONAL-ANTIBODIES [J].
WHITAKER, AN ;
ELMS, MJ ;
MASCI, PP ;
BUNDESEN, PG ;
RYLATT, DB ;
WEBBER, AJ ;
BUNCE, IH .
JOURNAL OF CLINICAL PATHOLOGY, 1984, 37 (08) :882-887