Poly(thionine)-carbon nanotube modified carbon film electrodes and application to the simultaneous determination of acetaminophen and dipyrone

被引:41
作者
Ghica, M. Emilia [1 ]
Ferreira, Grasyelle M. [1 ,2 ]
Brett, Christopher M. A. [1 ]
机构
[1] Univ Coimbra, Dept Chem, Fac Sci & Technol, P-3004535 Coimbra, Portugal
[2] Univ Fed Vales Jequitinhonha & Mucuri, Inst Ciencia & Tecnol, Diamantina, MG, Brazil
关键词
Carbon nanotubes; Poly(thionine); Electrochemical sensors; Acetaminophen; Dipyrone; SENSITIVE VOLTAMMETRIC SENSOR; ELECTROCHEMICAL SENSOR; PASTE ELECTRODE; ASCORBIC-ACID; URIC-ACID; PARACETAMOL; PERFORMANCE; BIOSENSORS; OXIDATION; CHITOSAN;
D O I
10.1007/s10008-015-2926-4
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Multi-walled carbon nanotube (MWCNT)-poly(thionine) (PTH) nanostructures were formed on carbon film electrodes (CFE), the polymer film being formed beneath or on top of MWCNT, to give two different sensor architectures, PTH/MWCNT/CFE or MWCNT/PTH/CFE. Characterization of the novel nanostructures was carried out by cyclic voltammetry, electrochemical impedance spectroscopy and scanning electron microscopy. The modified electrodes were then used for sensing acetaminophen (ACOP) and dipyrone by differential pulse voltammetry and fixed-potential amperometry independently and simultaneously. Analytical parameters were determined and the results compared with similarly modified electrodes reported in the literature. An interference study as well as recovery measurements in pharmaceutical samples was successfully performed.
引用
收藏
页码:2869 / 2881
页数:13
相关论文
共 44 条
[1]   Electrochemical preparation of composite of poly brilliant cresyl blue (PBCB)-poly 5-amino-2-napthalenesulfonic acid electrode and electrocatalytic application [J].
Balamurugan, A. ;
Chen, Shen-Ming .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2010, 14 (01) :35-41
[2]   Electrosynthesis and electrochemical characterisation of phenazine polymers for application in biosensors [J].
Barsan, Madalina M. ;
Pinto, Edilson M. ;
Brett, Christopher M. A. .
ELECTROCHIMICA ACTA, 2008, 53 (11) :3973-3982
[3]   Electrochemical sensors and biosensors based on redox polymer/carbon nanotube modified electrodes: A review [J].
Barsan, Madalina M. ;
Ghica, M. Emilia ;
Brett, Christopher M. A. .
ANALYTICA CHIMICA ACTA, 2015, 881 :1-23
[4]   New electrode architectures based on poly(methylene green) and functionalized carbon nanotubes: Characterization and application to detection of acetaminophen and pyridoxine [J].
Barsan, Madalina M. ;
Toledo, Camilla T. ;
Brett, Christopher M. A. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2015, 736 :8-15
[5]   Electrochemical behavior of a carbon paste electrode modified with 5-amino-3′,4′-dimethyl-biphenyl-2-ol/carbon nanotube and its application for simultaneous determination of isoproterenol, acetaminophen and N-acetylcysteine [J].
Beitollahi, Hadi ;
Mohadesi, Alireza ;
Mohammadi, Somayeh ;
Akbari, Ali .
ELECTROCHIMICA ACTA, 2012, 68 :220-226
[6]   Novel nanostructure-based electrochemical sensor for simultaneous determination of dopamine and acetaminophen [J].
Beitollahi, Hadi ;
Sheikhshoaie, Iran .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (02) :375-380
[7]   Disposable Solid-State Sensor Based on Polypyrrole Films Doped for Potentiometric Determination of Dipyrone in Human Urine and Pharmaceuticals Products [J].
Bindewald, Eduardo H. ;
Bergamini, Marcio F. ;
Marcolino-, Luiz H., Jr. .
ELECTROANALYSIS, 2013, 25 (06) :1535-1540
[8]  
Brett CMA, 2001, ELECTROANAL, V13, P765, DOI 10.1002/1521-4109(200105)13:8/9<765::AID-ELAN765>3.0.CO
[9]  
2-3
[10]   The efficacy of intravenous paracetamol versus dipyrone for postoperative analgesia after day-case lower abdominal surgery in children with spinal anesthesia: a prospective randomized double-blind placebo-controlled study [J].
Caliskan, Esra ;
Sener, Mesut ;
Kocum, Aysu ;
Ozyilkan, Nesrin Bozdogan ;
Ezer, Semire Serin ;
Aribogan, Anis .
BMC ANESTHESIOLOGY, 2013, 13