Marginal bone level buccal to mandibular molars in digital radiographs from charge-coupled device and storage phosphor systems - An in vitro study

被引:30
作者
Borg, E
Grondahl, K
Grondahl, HG
机构
[1] Department of Oral Diagnostic Radiology, Faculty of Odontology, University of Göteborg, Göteborg
关键词
radiography; dental; image enhancement; computer assisted; periodontal diseases;
D O I
10.1111/j.1600-051X.1997.tb00762.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The aim of this in vitro study was to compare bone loss measurements in the furcation area of mandibular molars in digital radiographs from a CCD-(Sens-A-Ray(R)) and a storage phosphor (Digora(R)) system. 10 1st and 7 2nd mandibular molars, with intact lingual but reduced buccal bone with furcation involvements, were used. Radiographs were first taken with lead markers at the most apical part of the buccal bone and at the cemento-enamel junction. These radiographs were used to establish a radiographically true distance between the CEJ and the buccal bone level. The lead marker at the CEJ served as a reference point for the observers' subsequent estimates of the extent of bone removed, which were made in radiographs without lead markers at the bone level. 1 exposure (400 ms) for the CCD- and 5 (160 ms, 200 ms, 250 ms, 320 ms, 400 ms) for the storage phosphor system were used. Measurements were made in unprocessed (original) and processed images (contrast enhanced and/or high pass filtered). The results showed underestimation of bone loss, but smaller than previously reported for him radiographs. No significant difference was found between the 2 systems when compared at the same exposure. Nor were any significant differences found between unprocessed and processed images or between storage phosphor images from different exposures. We conclude that digital radiographs are comparable to film based radiographs for measurement of buccal bone loss but that lower exposures can be used, especially with the storage phosphor system.
引用
收藏
页码:306 / 312
页数:7
相关论文
共 29 条
  • [1] COMPARISON OF PANORAMIC AND INTRAORAL RADIOGRAPHY AND POCKET PROBING FOR THE MEASUREMENT OF THE MARGINAL BONE LEVEL
    AKESSON, L
    HAKANSSON, J
    ROHLIN, M
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1992, 19 (05) : 326 - 332
  • [2] A REVIEW OF THE RELIABILITY OF RADIOGRAPHIC MEASUREMENTS IN ESTIMATING ALVEOLAR BONE CHANGES
    BENN, DK
    [J]. JOURNAL OF CLINICAL PERIODONTOLOGY, 1990, 17 (01) : 14 - 21
  • [3] BENN DK, 1996, DENTOMAXILLOFAC RAD, V25, P82
  • [4] DIRECT DIGITAL RADIOGRAPHY FOR THE DETECTION OF PERIODONTAL BONE-LESIONS
    FURKART, AJ
    DOVE, SB
    MCDAVID, WD
    NUMMIKOSKI, P
    MATTESON, S
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 74 (05): : 652 - 660
  • [5] LIMITATIONS OF RADIOGRAPH IN DIAGNOSIS OF OSSEOUS DEFECTS IN PERIODONTAL-DISEASE
    GOLDMAN, HM
    STALLARD, RE
    [J]. JOURNAL OF PERIODONTOLOGY, 1973, 44 (10) : 626 - 628
  • [6] GRONDAHL HG, 1994, DTSCH ZAHNARZTLICHE, V49, P358
  • [7] GRONDAHL HG, 1987, SWEDISH DENT J S, V50
  • [8] GURGAN C, 1995, DENTOMAXILLOFAC RAD, V24, P166
  • [9] HAMP SE, 1989, TXB CLIN PERIODONTOL, P515
  • [10] PERIODONTAL-DISEASE MORBIDITY QUANTIFICATION .2. VALIDATION OF ALVEOLAR BONE LOSS MEASUREMENTS AND VERTICAL DEFECT DIAGNOSIS FROM DIGITAL BITE-WING IMAGES
    HILDEBOLT, CF
    VANNIER, MW
    SHROUT, MK
    PILGRAM, TK
    PROVINCE, M
    VAHEY, EP
    RIETZ, DW
    [J]. JOURNAL OF PERIODONTOLOGY, 1990, 61 (10) : 623 - 632