Anodic stripping voltammetric determination of copper (II) ions at a graphene quantum dot-modified pencil graphite electrode

被引:14
|
作者
Ahour, F. [1 ]
Taheri, M. [1 ]
机构
[1] Urmia Univ, Fac Sci, Nanotechnol Res Ctr, Orumiyeh, Iran
关键词
Graphene quantum dot; Electrochemical detection; Cu (II) ions; Adsorptive stripping voltammetry; SIMULTANEOUS ELECTROCHEMICAL DETECTION; GLASSY-CARBON ELECTRODE; WATER SAMPLES; FOOD SAMPLES; CU(II); NANOCOMPOSITE; CADMIUM; SENSOR; OXIDE; CU2+;
D O I
10.1007/s13738-017-1235-5
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A simple and sensitive electrochemical sensor based on graphene quantum dot-modified pencil graphite electrode (GQD/PGE) was fabricated and used for highly selective and sensitive determination of copper (II) ions in nanomolar concentration by square wave adsorptive stripping voltammetric method. The sensing mechanism could be attributed to the formation of a complex between Cu2+ ions and oxygen-containing groups in GQDs which result in an increased SWV signal in comparison with the bare electrode. Optimization of various experimental parameters such as pre-concentration time, pre-concentration potential, pH, and buffer type which influence the performance of the sensor, was investigated. Under optimized condition, GQD-modified electrode has been used for the analysis of Cu2+ in the concentration range from 50 pM to 4 nM and a lower detection limit of 12 pM with good stability, repeatability, and selectivity. Finally, the practical applicability of GQD-PGE was confirmed via measuring trace amount of Cu (II) in water samples. The GQD/PGE surface could be regenerated by exerting more positive potentials than the stripping potential of the Cu (II) ion and then used for another deposition.
引用
收藏
页码:343 / 350
页数:8
相关论文
共 50 条
  • [41] Differential Pulse Voltammetric Determination of Folic Acid Using a Poly(Cystine) Modified Pencil Graphite Electrode
    Dokur, Ebrar
    Gorduk, Ozge
    Sahin, Yucel
    ANALYTICAL LETTERS, 2020, 53 (13) : 2060 - 2078
  • [42] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Huang, SS
    Cheng, YD
    Li, BF
    Liu, GD
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 97 - 101
  • [43] Simultaneous anodic stripping voltammetric determination of Pb(II) and Cd(II) using poly methyl thymol blue film-modified electrode
    Manikandan, Ramalingam
    Narayanan, Sangilimuthu Sriman
    IONICS, 2019, 25 (12) : 6083 - 6092
  • [44] Voltammetric determination of dihydroxybenzene isomers using a disposable pencil graphite electrode modified with cobalt-phthalocyanine
    Mihaela Buleandra
    Andreea Alexandra Rabinca
    Irinel Adriana Badea
    Adriana Balan
    Ioan Stamatin
    Constantin Mihailciuc
    Anton Alexandru Ciucu
    Microchimica Acta, 2017, 184 : 1481 - 1488
  • [45] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Sha-Sheng Huang
    Yi-Da Cheng
    Bi-Fen Li
    Guo-Dong Liu
    Microchimica Acta, 1998, 130 : 97 - 101
  • [46] ANODIC STRIPPING VOLTAMMETRIC DETERMINATION OF LEAD USING A CHEMICALLY MODIFIED ELECTRODE BASED ON AZA CROWN ETHER
    Segura, Rodrigo
    Diaz, Karina
    Pizarro, Jaime
    Placencio, Alan
    Tapia, Diego
    Fajardo, Angelo
    JOURNAL OF THE CHILEAN CHEMICAL SOCIETY, 2017, 62 (04): : 3726 - 3730
  • [47] Highly sensitive voltammetric electrode for the trace measurement of methyldopa based on a pencil graphite modified with phosphomolibdate/graphene oxide
    Dehnavi, Azar
    Soleymanpour, Ahmad
    MICROCHEMICAL JOURNAL, 2020, 157
  • [48] Nitrogen-doped Graphene Modified Glassy Carbon Electrode for Anodic Stripping Voltammetric Detection of Lead Ion
    Wen, Zuorui
    Niu, Xueliang
    Yan, Lijun
    Niu, Yanyan
    Wang, Dan
    Sun, Wei
    Shi, Zaifeng
    Dong, Lifeng
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2016, 11 (08): : 6648 - 6654
  • [49] Synthesis of Exclusive Star Shaped PbS Nanocrystals and Determination of Cd(II) Ions Using Hg(II)-PbS Modified Graphite Electrode by Differential Pulse Anodic Stripping Voltammetry
    Ramesh, P. S.
    Sangeetha, N. S.
    Kalaivani, A.
    Narayanan, S. Sriman
    ASIAN JOURNAL OF CHEMISTRY, 2013, 25 : S30 - S34
  • [50] Determination of Copper(II) and Cadmium(II) in Rice Samples by Anodic Stripping Square Wave Voltammetry Using Reduced Graphene Oxide/Polypyrrole Composite Modified Screen-printed Carbon Electrode
    Petsawi, Ploypailin
    Yaiwong, Patrawadee
    Laocharoensuk, Rawiwan
    Ounnunkad, Kontad
    CHIANG MAI JOURNAL OF SCIENCE, 2019, 46 (02): : 322 - 336