The OxyArM™:: A supplemental oxygen delivery device

被引:4
作者
Futrell, JW
Moore, JL
机构
[1] Kaiser Permanente Med Ctr, Dept Anesthesia, Bellflower, CA 90706 USA
[2] Cedars Sinai Med Ctr, Dept Anesthesiol, Los Angeles, CA 90048 USA
关键词
D O I
10.1213/01.ane.0000189822.98582.56
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Facemasks and nasal cannulae are used to provide supplemental oxygen to patients in the postoperative period after general anesthesia. These devices are associated with several patient complications, including aspiration, hypercarbia, and mechanical trauma. A new device, the OxyArm (TM), is designed to eliminate these problems. It is an "open oxygen" system that does not require physical contact with the patient's face. In this clinical study we evaluated the OxyArm (TM) in the immediate postoperative period. Sixty patients received supplemental oxygen via the OxyArm (TM) for the first 8 min after tracheal extubation after general anesthesia. Oxygen saturation values were continuously recorded during 3 4-min time periods: 1) while breathing oxygen through an endotracheal tube before tracheal extubation, 2) while breathing oxygen delivered by the OxyArm (TM) at 4 L/min 4 min after tracheal extubation, and 3) while breathing oxygen delivered by the OxyArm (TM) at 2 L/min 8 min after tracheal extubation. There were no significant differences in oxygen saturation among the three time periods and no patient experienced an oxygen desaturation event less than 88%. Patients and clinicians praised the OxyArm (TM) for its comfort and ease of use, allowing nursing facial care without interrupting oxygen therapy. We conclude that the OxyArm (TM) delivers adequate levels of oxygen for most patients during the early postoperative period.
引用
收藏
页码:491 / 494
页数:4
相关论文
共 24 条
[1]   MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES [J].
ALTMAN, DG ;
BLAND, JM .
JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) :307-317
[2]   Motion-resistant pulse oximetry: A comparison of new and old models [J].
Barker, SJ .
ANESTHESIA AND ANALGESIA, 2002, 95 (04) :967-972
[3]  
CANET J, 1984, EUR J RESPIR DIS, V65, P68
[4]   PULSE OXIMETRY FOR MONITORING DURING WARD ANALGESIA - EPIDURAL MORPHINE VERSUS PARENTERAL NARCOTICS [J].
CHOI, HJ ;
LITTLE, MS ;
GARBER, SZ ;
TREMPER, KK .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (02) :87-89
[5]   FALSELY NORMAL SATURATION READING WITH THE PULSE OXIMETER [J].
COSTARINO, AT ;
DAVIS, DA ;
KEON, TP .
ANESTHESIOLOGY, 1987, 67 (05) :830-831
[6]   RELATIONSHIP BETWEEN HYPOXEMIC AND CARDIAC ISCHEMIC EVENTS IN THE PERIOPERATIVE PERIOD [J].
GILL, NP ;
WRIGHT, B ;
REILLY, CS .
BRITISH JOURNAL OF ANAESTHESIA, 1992, 68 (05) :471-473
[7]  
GOLDSTEIN RS, 1982, LANCET, V2, P1188
[8]   SHOULD WE JUDGE A MASK BY ITS COVER [J].
JEFFREY, AA ;
WARREN, PM .
THORAX, 1992, 47 (07) :543-546
[9]   PULSE OXIMETRY [J].
KELLEHER, JF .
JOURNAL OF CLINICAL MONITORING, 1989, 5 (01) :37-62
[10]  
Ling E, 2002, CAN J ANAESTH, V49, P297, DOI 10.1007/BF03020531