Improvement in PET/CT Image Quality with a Combination of Point-Spread Function and Time-of-Flight in Relation to Reconstruction Parameters

被引:142
作者
Akamatsu, Go
Ishikawa, Kaori
Mitsumoto, Katsuhiko
Taniguchi, Takafumi
Ohya, Nobuyoshi [2 ]
Baba, Shingo [3 ]
Abe, Koichiro [3 ]
Sasaki, Masayuki [1 ]
机构
[1] Kyushu Univ, Div Med Quantum Sci, Dept Hlth Sci, Grad Sch Med Sci,Higashi Ku, Fukuoka 8128582, Japan
[2] Kyushu Univ Hosp, Dept Med Technol, Fukuoka 812, Japan
[3] Kyushu Univ, Grad Sch Med Sci, Dept Clin Radiol, Fukuoka 8128582, Japan
基金
日本学术振兴会;
关键词
point-spread function; time-of-flight; PET/CT; image quality; noise-equivalent counts; DOPED LUTETIUM OXYORTHOSILICATE; FULLY 3-D PET; POSITRON-EMISSION; SCAN DURATION; F-18-FDG PET; LUNG-CANCER; FDG-PET; IMPACT; SCINTILLATOR; EQUIVALENT;
D O I
10.2967/jnumed.112.103861
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of this study was to investigate the effects of the point-spread function (PSF) and time-of-flight (TOF) on improving F-18-FDG PET/CT images in relation to reconstruction parameters and noise-equivalent counts (NEC). Methods: This study consisted of a phantom study and a retrospective analysis of 39 consecutive patients who underwent clinical F-18-FDG PET/CT. The body phantom of the National Electrical Manufacturers Association and International Electrotechnical Commission with a 10-mm-diameter sphere was filled with an F-18-FDG solution with a 4:1 radioactivity ratio compared with the background. The PET data were reconstructed with the baseline ordered subsets expectation maximization (OSEM) algorithm, with the OSEM+PSF model, with the OSEM+TOF model, and with the OSEM+PSF+TOF model. We evaluated image quality by visual assessment, the signal-to-noise ratio of the 10-mm sphere (SNR10 mm), the contrast of the 10-mm sphere, and the coefficient of variance in the phantom study and then determined the optimal reconstruction parameters. We also examined the effects of PSF and TOF on the quality of clinical images using the signal-to-noise ratio in the liver (SNRliver) in relation to the NEC in the liver (NECliver). Results: In the phantom study, the SNR10 mm was the highest for the OSEM+PSF+TOF model, and the highest value was obtained at iteration 2 for algorithms with the TOF and at iteration 3 for those without the TOF. In terms of a postsmoothing filter full width at half maximum (FWHM), the high SNR10 mm was obtained with no filtering or was smaller than 2 mm for algorithms with PSF and was 4-6 mm for those without PSF. The balance between the contrast recovery and noise is different for algorithms with either PSF or TOF. A combination of PSF and TOF improved SNR10 mm, contrast, and coefficient of variance, especially with a small-FWHM gaussian filter. In the clinical study, the SNRliver Of the low-NECliver group in the OSEM+PSF+TOF model was compared with that of the high-NECliver group in conventional OSEM. The PSF+TOF improved the SNRliver by about 24.9% +/- 9.81%. Conclusion: A combination of PSF and TOF clearly improves image quality, whereas optimization of the reconstruction parameters is necessary to obtain the best performance for PSF or TOF. Furthermore, this combination has the potential to provide good image quality with either lower activity or shorter acquisition time, thus improving patient comfort and reducing the radiation burden.
引用
收藏
页码:1716 / 1722
页数:7
相关论文
共 33 条
[1]   Application and Evaluation of a Measured Spatially Variant System Model for PET Image Reconstruction [J].
Alessio, Adam M. ;
Stearns, Charles W. ;
Tong, Shan ;
Ross, Steven G. ;
Kohlmyer, Steve ;
Ganin, Alex ;
Kinahan, Paul E. .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2010, 29 (03) :938-949
[2]  
ALLEMAND R, 1980, J NUCL MED, V21, P153
[3]  
ANGER HO, 1966, ISA T, V5, P311
[4]  
Badawi RD, 2005, J NUCL MED, V46, P1767
[5]   Physical Performance of the new hybrid PET/CT Discovery-690 [J].
Bettinardi, V. ;
Presotto, L. ;
Rapisarda, E. ;
Picchio, M. ;
Gianolli, L. ;
Gilardi, M. C. .
MEDICAL PHYSICS, 2011, 38 (10) :5394-5411
[6]  
Brownell GL., 1969, Medical Radioisotope Scintigraphy, V1, P163
[7]   Focus on time-of-flight PET: the benefits of improved time resolution [J].
Conti, Maurizio .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 (06) :1147-1157
[8]   EVALUATION OF CERIUM-DOPED LUTETIUM OXYORTHOSILICATE (LSO) SCINTILLATION CRYSTAL FOR PET [J].
DAGHIGHIAN, F ;
SHENDEROV, P ;
PENTLOW, KS ;
GRAHAM, MC ;
ESHAGHIAN, B ;
MELCHER, CL ;
SCHWEITZER, JS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1993, 40 (04) :1045-1047
[9]  
Delbeke D, 1999, J NUCL MED, V40, P591
[10]   Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET [J].
El Fakhri, Georges ;
Surti, Suleman ;
Trott, Cathryn M. ;
Scheuermann, Joshua ;
Karp, Joel S. .
JOURNAL OF NUCLEAR MEDICINE, 2011, 52 (03) :347-353