Experimental Optimization of Passive Cooling of a Heat Source Array Flush-Mounted on a Vertical Plate

被引:4
|
作者
Baudoin, Antoine [1 ]
Saury, Didier [2 ]
Zhu, Bo [2 ]
Bostrom, Cecilia [1 ]
机构
[1] Uppsala Univ, Div Elect, Box 534, S-75121 Uppsala, Sweden
[2] Univ Poitiers, ENSMA, CNRS, Inst PPRIME, BP 40109, F-86961 Futuroscope, Chassencuil, France
关键词
discrete heat sources; source array; natural convection; optimization; NATURAL-CONVECTION; ENCLOSURES; CHANNEL;
D O I
10.3390/en9110912
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heat sources, such as power electronics for offshore power, could be cooled passively-mainly by conduction and natural convection. The obvious advantage of this strategy is its high reliability. However, it must be implemented in an efficient manner (i.e., the area needs to be kept low to limit the construction costs). In this study, the placement of multiple heat sources mounted on a vertical plate was studied experimentally for optimization purposes. We chose a regular distribution, as this is likely to be the preferred choice in the construction process. We found that optimal spacing can be determined for a targeted source density by tuning the vertical and horizontal spacing between the heat sources. The optimal aspect ratio was estimated to be around two.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Three-dimensional convective cooling in a vertical channel with flush-mounted heat sources
    Gunes, H
    Liakopoulos, A
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2003, 46 (05) : 791 - 808
  • [2] Pool boiling heat transfer with an array of flush-mounted, square heaters on a vertical surface
    You, SM
    Simon, TW
    BarCohen, A
    JOURNAL OF ELECTRONIC PACKAGING, 1997, 119 (01) : 17 - 25
  • [3] Shape optimization of a flat channel with an array of discrete, flush-mounted heat sources on one plate being cooled by forced convective water
    Campo, Antonio
    Johnson, Richard
    Landon, Mark D.
    Cabezas-Gomez, Luben
    INTERNATIONAL JOURNAL OF NUMERICAL METHODS FOR HEAT & FLUID FLOW, 2010, 20 (3-4) : 286 - 297
  • [4] The flush-mounted rail Langmuir probe array designed for the Alcator C-Mod vertical target plate divertor
    Kuang, A. Q.
    Brunner, D.
    LaBombard, B.
    Leccacorvi, R.
    Vieira, R.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2018, 89 (04):
  • [5] EXPERIMENTAL INVESTIGATION OF FLUSH-MOUNTED ELECTROSTATIC PROBES
    SCHARFMAN, WE
    BREDFELD.HR
    AIAA JOURNAL, 1970, 8 (04) : 662 - +
  • [6] Buckling of a flush-mounted plate in simple shear flow
    H. Luo
    C. Pozrikidis
    Archive of Applied Mechanics, 2006, 76 : 549 - 566
  • [7] Buckling of a flush-mounted plate in simple shear flow
    Luo, H.
    Pozrikidis, C.
    ARCHIVE OF APPLIED MECHANICS, 2006, 76 (9-10) : 549 - 566
  • [8] ELECTRONICALLY DESPUN ARRAY FLUSH-MOUNTED ON A CYLINDRICAL SPACECRAFT
    GREGORWICH, WS
    IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1974, AP22 (01) : 71 - 74
  • [9] An experimental study on forced convection heat transfer from flush-mounted discrete heat sources
    Tso, C.P.
    Xu, G.P.
    Tou, K.W.
    Journal of Heat Transfer, 1999, 121 (02): : 326 - 332
  • [10] EXPERIMENTAL INVESTIGATION ON FLOW AND HEAT TRANSFER FOR COOLING FLUSH-MOUNTED RIBBONS IN A CHANNEL Application of an Electrohydrodinamics Active Enhancement Method
    Aalmi Nia, Amin
    Campo, Antonio
    THERMAL SCIENCE, 2016, 20 (02): : 505 - 516