Wearable Sensor-Based Exercise Biofeedback for Orthopaedic Rehabilitation: A Mixed Methods User Evaluation of a Prototype System

被引:48
作者
Argent, Rob [1 ,2 ,3 ]
Slevin, Patrick [2 ,3 ]
Bevilacqua, Antonio [2 ]
Neligan, Maurice [1 ]
Daly, Ailish [1 ]
Caulfield, Brian [2 ,3 ]
机构
[1] Beacon Hosp, Dublin 18, Ireland
[2] Univ Coll Dublin, Insight Ctr Data Analyt, Dublin 4, Ireland
[3] Univ Coll Dublin, Sch Publ Hlth Physiotherapy & Sport Sci, Dublin 4, Ireland
基金
欧盟地平线“2020”;
关键词
biofeedback; biomedical technology; exercise therapy; orthopedics; mobile health; qualitative; human factors; wearables; inertial measurement unit; CONNECTED HEALTH; SELF-MANAGEMENT; OLDER-ADULTS; ADHERENCE; INTERVENTIONS; CARE;
D O I
10.3390/s19020432
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The majority of wearable sensor-based biofeedback systems used in exercise rehabilitation lack end-user evaluation as part of the development process. This study sought to evaluate an exemplar sensor-based biofeedback system, investigating the feasibility, usability, perceived impact and user experience of using the platform. Fifteen patients participated in the study having recently undergone knee replacement surgery. Participants were provided with the system for two weeks at home, completing a semi-structured interview alongside the System Usability Scale (SUS) and user version of the Mobile Application Rating Scale (uMARS). The analysis from the SUS (mean = 90.8 [SD = 7.8]) suggests a high degree of usability, supported by qualitative findings. The mean adherence rate was 79% with participants reporting a largely positive user experience, suggesting it offers additional support with the rehabilitation regime. Overall quality from the mean uMARS score was 4.1 out of 5 (SD = 0.39), however a number of bugs and inaccuracies were highlighted along with suggestions for additional features to enhance engagement. This study has shown that patients perceive value in the use of wearable sensor-based biofeedback systems and has highlighted the benefit of user-evaluation during the design process, illustrated the need for real-world accuracy validation, and supports the ongoing development of such systems.
引用
收藏
页数:13
相关论文
共 44 条
[1]  
Alexandre Neusa Maria Costa, 2002, Rev Panam Salud Publica, V12, P86, DOI 10.1590/S1020-49892002000800003
[2]   Clinician perceptions of a prototype wearable exercise biofeedback system for orthopaedic rehabilitation: a qualitative exploration [J].
Argent, Rob ;
Slevin, Patrick ;
Bevilacqua, Antonio ;
Neligan, Maurice ;
Daly, Ailish ;
Caulfield, Brian .
BMJ OPEN, 2018, 8 (10)
[3]   Patient Involvement With Home-Based Exercise Programs: Can Connected Health Interventions Influence Adherence? [J].
Argent, Rob ;
Daly, Ailish ;
Caulfield, Brian .
JMIR MHEALTH AND UHEALTH, 2018, 6 (03)
[4]   An empirical evaluation of the System Usability Scale [J].
Bangor, Aaron ;
Kortum, Philip T. ;
Miller, James T. .
INTERNATIONAL JOURNAL OF HUMAN-COMPUTER INTERACTION, 2008, 24 (06) :574-594
[5]  
Bangor A, 2009, J USABILITY STUD, V4, P114
[6]   Body-Worn Sensor Design: What Do Patients and Clinicians Want? [J].
Bergmann, J. H. M. ;
McGregor, A. H. .
ANNALS OF BIOMEDICAL ENGINEERING, 2011, 39 (09) :2299-2312
[7]   An Attachable Clothing Sensor System for Measuring Knee Joint Angles [J].
Bergmann, Jeroen H. M. ;
Anastasova-Ivanova, Salzitsa ;
Spulber, Irina ;
Gulati, Vivek ;
Georgiou, Pantelis ;
McGregor, Alison .
IEEE SENSORS JOURNAL, 2013, 13 (10) :4090-4097
[8]  
Bevilacqua A, 2018, INT CONF WEARAB IMPL, P21, DOI 10.1109/BSN.2018.8329649
[9]  
Beyer H.R., 2010, USER CTR DESIGN, P1308
[10]   Self-management of chronic pain: a population-based study [J].
Blyth, FM ;
March, LM ;
Nicholas, MK ;
Cousins, MJ .
PAIN, 2005, 113 (03) :285-292