Malignant pulmonary nodules in a patient with neoplasia alters clinical staging and therapy. Although it may be difficult, it is imperative to obtain a tissue diagnosis of such nodules. We describe a coaxial technique using controlled respirations, which we have found useful for biopsy of small pulmonary nodules in children. Clinical records, imaging and pathology (histology and cytology) were reviewed for 17 children who had 18 nodules biopsied in the method described. A diagnosis of malignant or benign tissue was made in 15 nodules. One biopsy was inadequate and there was one false-negative. Adequate cores were obtained in 15 nodules, cytology in 2 and inadequate material in 1. There was no significant morbidity.
引用
收藏
页码:342 / 346
页数:5
相关论文
共 12 条
[1]   IMAGE-GUIDED AUTOMATED CORE BIOPSIES OF THE BREAST, CHEST, ABDOMEN, AND PELVIS [J].
BURBANK, F ;
KAYE, K ;
BELVILLE, J ;
EKUAN, J ;
BLUMENFELD, M .
RADIOLOGY, 1994, 191 (01) :165-171
[2]  
CASTAUEDAZUNIGA WR, 1997, INTERVENTIONAL RADIO, V2, P1785
[3]   LUNG CT FOR DETECTION OF METASTASES - SOLID TISSUE NEOPLASMS IN CHILDREN [J].
COHEN, M ;
GROSFELD, J ;
BAEHNER, R ;
WEETMAN, R .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1982, 139 (05) :895-898
[4]   LOCALIZATION OF SMALL PULMONARY NODULES FOR THORACOSCOPIC RESECTION - USE OF A NEWLY DEVELOPED HOOKWIRE SYSTEM [J].
KANAZAWA, S ;
ANDO, A ;
YASUI, K ;
TANAKA, A ;
HIRAKI, Y .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1995, 18 (02) :122-124
[5]  
KAYE RD, 1993, RADIOL CLIN N AM, V31, P693
[6]   Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: Results in 122 patients [J].
Klein, JS ;
Salomon, G ;
Stewart, EA .
RADIOLOGY, 1996, 198 (03) :715-720
[7]   COAXIAL PERCUTANEOUS BIOPSY TECHNIQUE WITH AUTOMATED BIOPSY DEVICES - VALUE IN IMPROVING ACCURACY AND NEGATIVE PREDICTIVE VALUE [J].
MOULTON, JS ;
MOORE, PT .
RADIOLOGY, 1993, 186 (02) :515-522
[8]   Small pulmonary lesions detected at CT: Clinical importance [J].
Munden, RF ;
Pugatch, RD ;
Liptay, MJ ;
Sugarbaker, DJ ;
Le, LU .
RADIOLOGY, 1997, 202 (01) :105-110
[9]   PERCUTANEOUS NEEDLE-BIOPSY OF LOCALIZED PULMONARY, MEDIASTINAL, AND PLEURAL DISEASED TISSUE WITH AN AUTOMATIC DISPOSABLE GUILLOTINE SOFT-TISSUE NEEDLE - PRELIMINARY-RESULTS [J].
NOPPEN, MMP ;
DEMEY, J ;
MEYSMAN, M ;
OPDEBEECK, B ;
VINCKEN, WG ;
OSTEAUX, M .
CHEST, 1995, 107 (06) :1615-1620
[10]  
SPENCER DA, 1996, PEDIAT PULMONOL, V22, P83