IQ Signal Demodulation for Noncontact Vital Sign Monitoring Using a CW Doppler Radar: A Review

被引:30
作者
Wang, Fu-Kang [1 ]
Zhong, Ji-Xun [2 ]
Shih, Ju-Yin [3 ]
机构
[1] Natl Sun Yat sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
[2] Natl Sun Yat sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
[3] Natl Sun Yat sen Univ, Dept Elect Engn, Kaohsiung, Taiwan
来源
IEEE JOURNAL OF ELECTROMAGNETICS RF AND MICROWAVES IN MEDICINE AND BIOLOGY | 2022年 / 6卷 / 04期
关键词
noncontact detection; null-point issue; signal demodulation; vital sign; Doppler radar; INJECTION-LOCKED RADAR; CONTINUOUS-WAVE RADAR; HEART-RATE; QUADRATURE IMBALANCE; TRANSFORM; RANGE; COMPENSATION; DISPLACEMENT; ALGORITHM; BENEFITS;
D O I
10.1109/JERM.2022.3214753
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Using a Doppler radar for noncontact detection is a promising way to monitor vital signs of a subject more conveniently than other common contact medical devices, but has many challenges including null-point issue, dc offset, and nonlinear distortion. The wireless property of a radar system easily affects the Doppler signals, so it needs a demodulation method to obtain the vital sign information. Furthermore, detecting precise information for respiration rate (RR) and heart rate (HR) of the subject needs further signal processing to extract the target signals from the demodulated signals at various interference levels. Hence, this study reviews research on continuous-wave (CW) Doppler radar, signal demodulation and subsequent signal processing to address the problems for noncontact vital sign monitoring.
引用
收藏
页码:449 / 460
页数:12
相关论文
共 80 条
[71]   Robust Doppler radar demodulation via compressed sensing [J].
Xu, W. ;
Gu, C. ;
Li, C. ;
Sarrafzadeh, M. .
ELECTRONICS LETTERS, 2012, 48 (22) :1428-1429
[72]   Large Displacement Motion Interferometry With Modified Differentiate and Cross-Multiply Technique [J].
Xu, Wei ;
Li, Yuchen ;
Gu, Changzhan ;
Mao, Jun-Fa .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2021, 69 (11) :4879-4890
[73]  
Yamamoto K., 2020, IEEE ACCESS, V8
[74]  
Yamamoto K., 2020, IEEE ACCESS, V8
[75]  
Yavari E., 2012, 2012 IEEE Topical Conference on Biomedical Wireless Technologies, Networks, and Sensing Systems (BioWireleSS), P25, DOI 10.1109/BioWireless.2012.6172739
[76]   Quadrature Imbalance Compensation With Ellipse-Fitting Methods for Microwave Radar Physiological Sensing [J].
Zakrzewski, Mari ;
Singh, Aditya ;
Yavari, Ehsan ;
Gao, Xiaomeng ;
Boric-Lubecke, Olga ;
Vanhala, Jukka ;
Palovuori, Karri .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2014, 62 (06) :1400-1408
[77]   Comparison of Center Estimation Algorithms for Heart and Respiration Monitoring With Microwave Doppler Radar [J].
Zakrzewski, Mari ;
Raittinen, Harri ;
Vanhala, Jukka .
IEEE SENSORS JOURNAL, 2012, 12 (03) :627-634
[78]   Directional discrete cosine transforms - A new framework for image coding [J].
Zeng, Bing ;
Fu, Jingjing .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS FOR VIDEO TECHNOLOGY, 2008, 18 (03) :305-313
[79]   Kalman Filter and Cross-Multiply Algorithm With Adaptive DC Offset Removal [J].
Zhang, Li ;
Fu, Chang-Hong ;
Zhuang, Zhongxu ;
Yang, Xuan ;
Ding, Genming ;
Hong, Hong ;
Zhu, Xiaohua .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71
[80]   Noncontact Physiological Dynamics Detection Using Low-power Digital-IF Doppler Radar [J].
Zhao, Heng ;
Hong, Hong ;
Sun, Li ;
Li, Yusheng ;
Li, Changzhi ;
Zhu, Xiaohua .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2017, 66 (07) :1780-1788