Development of an optimized electrochemical process for subsequent coating of 316 stainless steel for stent applications

被引:98
作者
Haidopoulos, M. [1 ]
Turgeon, S. [1 ]
Sarra-Bournet, C. [1 ]
Laroche, G. [1 ]
Mantovani, D. [1 ]
机构
[1] Univ Laval, Lab Biomat & Bioengn, Quebec City, PQ G1K 7P4, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
D O I
10.1007/s10856-006-9228-4
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Metallic endovascular stents are used as medical devices to scaffold biological lumen, most often diseased arteries, after balloon angioplasty. They are commonly made of 316L stainless steel or Nitinol, two alloys containing nickel, an element classified as potentially toxic and carcinogenic by the International Agency for Research on Cancer. Although they are largely implanted, the long-term safety of such metallic elements is still controversial, since the corrosion processes may lead to the release of several metallic ions, including nickel ions in diverse oxidation states. To avoid metallic ion release in the body, the strategy behind this work was to develop a process aiming the complete isolation of the stainless steel device from the body fluids by a thin, cohesive and strongly adherent coating of RF-plasma-polymerized fluoropolymer. Nevertheless, prior to the polymer film deposition, an essential aspect was the development of a pre-treatment for the metallic substrate, based on the electrochemical polishing process, aiming the removal of any fragile interlayer, including the native oxide layer and the carbon contaminated layer, in order to obtain a smooth, defect-free surface to optimize the adhesion of the plasma-deposited thin film. In this work, the optimized parameters for electropolishing, such as the duration and the temperature of the electrolysis, and the complementary acid dipping were presented and accurately discussed. Their effects on roughness as well as on the evolution of surface topography were investigated by Atomic Force Microscopy, stylus profilometry and Scanning Electron Microscopy. The modifications induced on the surface atomic concentrations were studied by X-ray Photoelectron Spectroscopy. The improvements in terms of the surface morphology after the pre-treatment were also emphasized, as well as the influence of the original stainless steel surface finish.
引用
收藏
页码:647 / 657
页数:11
相关论文
共 40 条
[1]   A REVIEW OF THE STAINLESS-STEEL SURFACE [J].
ADAMS, RO .
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A-VACUUM SURFACES AND FILMS, 1983, 1 (01) :12-18
[2]   Coated scents for the prevention of restenosis: Part II [J].
Babapulle, MN ;
Eisenberg, MJ .
CIRCULATION, 2002, 106 (22) :2859-2866
[3]   Biocompatibility aspects of new stent technology [J].
Bertrand, OF ;
Sipehia, R ;
Mongrain, R ;
Rodés, JR ;
Tardif, JC ;
Bilodeau, L ;
Côté, G ;
Bourassa, MG .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) :562-571
[4]   INFLUENCE OF PRE-VACUUM SURFACE CONDITIONING ON THE RESPONSE WITH ELECTRON-STIMULATED DESORPTION AT STAINLESS-STEEL SURFACES IN UHV [J].
BHASAVANICH, D ;
WILLIAMS, EM .
VACUUM, 1980, 30 (02) :91-92
[5]   Passivation mechanism of iron in concentrated phosphoric acid [J].
Bojinov, M ;
Betova, I ;
Fabricius, G ;
Laitinen, T ;
Raicheff, R .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1999, 475 (01) :58-65
[6]   IN-VIVO TRANSPORT AND EXCRETION OF CORROSION PRODUCTS FROM ACCELERATED ANODIC CORROSION OF POROUS-COATED F75 ALLOY [J].
BROWN, SA ;
ZHANG, K ;
MERRITT, K ;
PAYER, JH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (08) :1007-1017
[7]  
CAIRE JP, 1993, AESF ANN TECHN C
[8]  
De Scheerder I, 1998, Semin Interv Cardiol, V3, P139
[9]   SPECTROSCOPIC CHARACTERIZATION OF STAINLESS-STEEL SURFACES TREATED BY PLASMA [J].
DESHAYES, L ;
CHARBONNIER, M ;
PRAKASH, NS ;
GAILLARD, F ;
ROMAND, M .
SURFACE AND INTERFACE ANALYSIS, 1994, 21 (10) :711-717
[10]  
Duerig TW, 2001, MATER SCI FORUM, V394-3, P1, DOI 10.4028/www.scientific.net/MSF.394-395.1