CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems

被引:15
|
作者
Wade, Djibril [1 ,2 ,3 ]
Diaw, Papa Alassane [1 ]
Daneau, Geraldine [2 ]
Camara, Makhtar [1 ]
Dieye, Tandakha Ndiaye [1 ]
Mboup, Souleymane [1 ]
Kestens, Luc [2 ,3 ]
机构
[1] Le Dantec Univ Teaching Hosp, Immunol Unit, Bacteriol Lab, Dakar, Senegal
[2] Inst Trop Med, Immunol Lab, Dept Biomed Sci, B-2000 Antwerp, Belgium
[3] Univ Antwerp, Dept Biomed Sci, B-2020 Antwerp, Belgium
来源
PLOS ONE | 2013年 / 8卷 / 09期
关键词
HIV-INFECTED INDIVIDUALS; FLOW-CYTOMETRY; PERFORMANCE EVALUATION; ALTERNATIVE METHODS; POINT; LYMPHOCYTES; ANALYZER; BLOOD; COEFFICIENT; CLINICS;
D O I
10.1371/journal.pone.0075484
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Flow Cytometry (FCM) is still considered to be the method of choice for accurate CD4 enumeration. However, the use of FCM in developing countries is problematic due to their cost and complexity. Lower-cost technologies have been introduced. We evaluated CyFlow Counter together with its lyophilized reagents, and Pima CD4 in high-temperature area, using FACSCount as reference. Materials and Methods: Whole blood samples were consecutively collected by venipuncture from 111 HIV+ patients and 17 HIV-negative donors. CD4 T-cell enumeration was performed on CyFlow Counter, Pima CD4 and FACSCount. Results: CyFlow Counter and Pima CD4 systems showed good correlation with FACSCount (slope of 0.82 and 0.90, and concordance rho(c) of 0.94 and 0.98, respectively). CyFlow Counter showed absolute or relative biases (LOA) of 263 cells/mm(3) (-245 to 120) or -9.8% (-38.1 to 18.4) respectively, and Pima CD4 showed biases (LOA) of -30 cells/mm(3) (-160 to 101) or -3.5% (-41.0 to 33.9%). CyFlow Counter and Pima CD4 showed respectively 106.7% and 105.9% of similarity with FACSCount. According to WHO-2010 ART initiation threshold of 350 cells/mm(3), CyFlow Counter and Pima CD4 showed respectively sensibility of 100% and 97%, and specificity of 91% and 93%. CyFlow Counter and Pima CD4 were strongly correlated (slope of 1.09 and rho(c) of 0.95). These alternative systems showed good agreement with bias of 33 cells/mm(3) (-132 to 203) or 6.3% (-31.2 to 43.8), and similarity of 104.3%. Conclusion: CyFlow Counter using CD4 easy count kit-dry and Pima CD4 systems can accurately provide CD4 T-cell counts with acceptable agreement to those of FACSCount.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Atherosclerosis Impairs Naive CD4 T-Cell Responses via Disruption of Glycolysis
    Gaddis, Dalia E.
    Padgett, Lindsey E.
    Wu, Runpei
    Nguyen, Anh
    McSkimming, Chantel
    Dinh, Huy Q.
    Araujo, Daniel J.
    Taylor, Angela M.
    McNamara, Coleen A.
    Hedrick, Catherine C.
    ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2021, 41 (09) : 2387 - 2398
  • [42] An Integrative Network Modeling Approach to T CD4 Cell Activation
    Martinez-Mendez, David
    Villarreal, Carlos
    Mendoza, Luis
    Huerta, Leonor
    FRONTIERS IN PHYSIOLOGY, 2020, 11
  • [43] CD4 T-cell Subsets and Tumor Immunity: The Helpful and the Not-so-Helpful
    Kim, Hye-Jung
    Cantor, Harvey
    CANCER IMMUNOLOGY RESEARCH, 2014, 2 (02) : 91 - 98
  • [44] Performance evaluation of the touchscreen-based Muse™ Auto CD4/CD4% single-platform system for CD4 T cell numeration in absolute number and in percentage using blood samples from children and adult patients living in the Central African Republic
    Christian Diamant Mossoro-Kpinde
    André Kouabosso
    Ralph-Sydney Mboumba Bouassa
    Jean De Dieu Longo
    Edouard Kokanzo
    Rosine Féissona
    Gérard Grésenguet
    Laurent Bélec
    Journal of Translational Medicine, 14
  • [45] Performance evaluation of the touchscreen-based Muse™ Auto CD4/ CD4% single-platform system for CD4 T cell numeration in absolute number and in percentage using blood samples from children and adult patients living in the Central African Republic
    Mossoro-Kpinde, Christian Diamant
    Kouabosso, Andre
    Bouassa, Ralph-Sydney Mboumba
    Longo, Jean De Dieu
    Kokanzo, Edouard
    Feissona, Rosine
    Gresenguet, Gerard
    Belec, Laurent
    JOURNAL OF TRANSLATIONAL MEDICINE, 2016, 14
  • [46] B Cell and CD4 T Cell Interactions Promote Development of Atherosclerosis
    Tay, Christopher
    Kanellakis, Peter
    Hosseini, Hamid
    Cao, Anh
    Toh, Ban-Hock
    Bobik, Alex
    Kyaw, Tin
    FRONTIERS IN IMMUNOLOGY, 2020, 10
  • [47] Evaluation of PIMA point-of-care CD4 testing in a large UK HIV service
    Herbert, Sophie
    Edwards, Simon
    Carrick, Gina
    Copas, Andrew
    Sandford, Christopher
    Amphlett, Marc
    Benn, Paul
    SEXUALLY TRANSMITTED INFECTIONS, 2012, 88 (06) : 413 - 417
  • [48] Factors associated with the CD4(+) lymphocyte count at diagnosis of acquired immunodeficiency
    Phillips, AN
    Lazzarin, A
    GonzalesLahoz, J
    Clumeck, N
    Glauser, MP
    Proenca, R
    Banhegyi, D
    Pedersen, C
    Lundgren, JD
    Johnson, AM
    JOURNAL OF CLINICAL EPIDEMIOLOGY, 1996, 49 (11) : 1253 - 1258
  • [49] CD4 Enumeration Technologies: A Systematic Review of Test Performance for Determining Eligibility for Antiretroviral Therapy
    Peeling, Rosanna W.
    Sollis, Kimberly A.
    Glover, Sarah
    Crowe, Suzanne M.
    Landay, Alan L.
    Cheng, Ben
    Barnett, David
    Denny, Thomas N.
    Spira, Thomas J.
    Stevens, Wendy S.
    Crowley, Siobhan
    Essajee, Shaffiq
    Vitoria, Marco
    Ford, Nathan
    PLOS ONE, 2015, 10 (03):
  • [50] The BD FACSPresto Point of Care CD4 Test Accurately Enumerates CD4+T Cell Counts
    Bwana, Priska
    Vojnov, Lara
    Adhiambo, Maureen
    Akinyi, Catherine
    Mwende, Joy
    Prescott, Marta
    Mwau, Matilu
    PLOS ONE, 2015, 10 (12):