CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems

被引:15
|
作者
Wade, Djibril [1 ,2 ,3 ]
Diaw, Papa Alassane [1 ]
Daneau, Geraldine [2 ]
Camara, Makhtar [1 ]
Dieye, Tandakha Ndiaye [1 ]
Mboup, Souleymane [1 ]
Kestens, Luc [2 ,3 ]
机构
[1] Le Dantec Univ Teaching Hosp, Immunol Unit, Bacteriol Lab, Dakar, Senegal
[2] Inst Trop Med, Immunol Lab, Dept Biomed Sci, B-2000 Antwerp, Belgium
[3] Univ Antwerp, Dept Biomed Sci, B-2020 Antwerp, Belgium
来源
PLOS ONE | 2013年 / 8卷 / 09期
关键词
HIV-INFECTED INDIVIDUALS; FLOW-CYTOMETRY; PERFORMANCE EVALUATION; ALTERNATIVE METHODS; POINT; LYMPHOCYTES; ANALYZER; BLOOD; COEFFICIENT; CLINICS;
D O I
10.1371/journal.pone.0075484
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Flow Cytometry (FCM) is still considered to be the method of choice for accurate CD4 enumeration. However, the use of FCM in developing countries is problematic due to their cost and complexity. Lower-cost technologies have been introduced. We evaluated CyFlow Counter together with its lyophilized reagents, and Pima CD4 in high-temperature area, using FACSCount as reference. Materials and Methods: Whole blood samples were consecutively collected by venipuncture from 111 HIV+ patients and 17 HIV-negative donors. CD4 T-cell enumeration was performed on CyFlow Counter, Pima CD4 and FACSCount. Results: CyFlow Counter and Pima CD4 systems showed good correlation with FACSCount (slope of 0.82 and 0.90, and concordance rho(c) of 0.94 and 0.98, respectively). CyFlow Counter showed absolute or relative biases (LOA) of 263 cells/mm(3) (-245 to 120) or -9.8% (-38.1 to 18.4) respectively, and Pima CD4 showed biases (LOA) of -30 cells/mm(3) (-160 to 101) or -3.5% (-41.0 to 33.9%). CyFlow Counter and Pima CD4 showed respectively 106.7% and 105.9% of similarity with FACSCount. According to WHO-2010 ART initiation threshold of 350 cells/mm(3), CyFlow Counter and Pima CD4 showed respectively sensibility of 100% and 97%, and specificity of 91% and 93%. CyFlow Counter and Pima CD4 were strongly correlated (slope of 1.09 and rho(c) of 0.95). These alternative systems showed good agreement with bias of 33 cells/mm(3) (-132 to 203) or 6.3% (-31.2 to 43.8), and similarity of 104.3%. Conclusion: CyFlow Counter using CD4 easy count kit-dry and Pima CD4 systems can accurately provide CD4 T-cell counts with acceptable agreement to those of FACSCount.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Assessment of two POC technologies for CD4 count in Morocco
    Elharti, Elmir
    Abbadi, Halima
    Bensghir, Rajae
    Marhoum El Filali, Kamal
    Elmrabet, Hajar
    Oumzil, Hicham
    AIDS RESEARCH AND THERAPY, 2020, 17 (01)
  • [32] Performance evaluation of the MBio Diagnostics point-of-care CD4 counter
    Logan, Cathy
    Givens, Monique
    Ives, Jeffrey T.
    Delaney, Marie
    Lochhead, Michael J.
    Schooley, Robert T.
    Benson, Constance A.
    JOURNAL OF IMMUNOLOGICAL METHODS, 2013, 387 (1-2) : 107 - 113
  • [33] CD4 CTL, a Cytotoxic Subset of CD4+ T Cells, Their Differentiation and Function
    Takeuchi, Arata
    Saito, Takashi
    FRONTIERS IN IMMUNOLOGY, 2017, 8
  • [34] Memory CD4 T-cell subsets discriminated by CD43 expression level in A-bomb survivors
    Kyoizumi, Seishi
    Yamaoka, Mika
    Kubo, Yoshiko
    Hamasaki, Kanya
    Hayashi, Tomonori
    Nakachi, Kei
    Kasagi, Fumiyoshi
    Kusunoki, Yoichiro
    INTERNATIONAL JOURNAL OF RADIATION BIOLOGY, 2010, 86 (01) : 56 - 62
  • [35] Comparison of different methodologies for CD4 estimation in a clinical setting
    Jeganathan, S.
    Bansal, M.
    Smith, D. E.
    Gold, J.
    HIV MEDICINE, 2008, 9 (04) : 192 - 195
  • [36] ALCAM on human oligodendrocytes mediates CD4 T cell adhesion
    Jamann, Helene
    Desu, Haritha L.
    Cui, Qiao-Ling
    Halaweh, Alexandre
    Tastet, Olivier
    Klement, Wendy
    Zandee, Stephanie
    Pernin, Florian
    Mamane, Victoria H.
    Ouedraogo, Oumarou
    Daigneault, Audrey
    Sidibe, Hadjara
    Millette, Florence
    Peelen, Evelyn
    Dhaeze, Tessa
    Hoornaert, Chloe
    Rebillard, Rose-Marie
    Thai, Karine
    Grasmuck, Camille
    Vande Velde, Christine
    Prat, Alexandre
    Arbour, Nathalie
    Stratton, Jo Anne
    Antel, Jack
    Larochelle, Catherine
    BRAIN, 2024, 147 (01) : 147 - 162
  • [37] Homeostatic cytokines orchestrate the segregation of CD4 and CD8 memory T-cell reservoirs in mice
    Yang, Lili
    Yu, Yang
    Kalwani, Manorama
    Tseng, Tai-Wei Joy
    Baltimore, David
    BLOOD, 2011, 118 (11) : 3039 - 3050
  • [38] Interleukin-2 Therapy Induces CD4 Downregulation, Which Decreases Circulating CD4 T Cell Counts, in African Green Monkeys
    Mudd, Joseph C.
    Perkins, Molly R.
    DiNapoli, Sarah R.
    Hirsch, Vanessa M.
    Brenchley, Jason M.
    JOURNAL OF VIROLOGY, 2016, 90 (12) : 5750 - 5758
  • [39] New BD FACSCount™ CD4 reagent system for simultaneous enumeration of percent and absolute CD4 T-lymphocytes in HIV-1-Infected pediatric patients
    Pattanapanyasat, Kovit
    Sukapirom, Kasama
    Kowawisatsut, Laddawan
    Thepthai, Charin
    CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B : S98 - S106
  • [40] CD4 cell count at initiation of ART, long-term likelihood of achieving CD4 >750 cells/mm3 and mortality risk
    Palella, F. J., Jr.
    Armon, C.
    Chmiel, J. S.
    Brooks, J. T.
    Hart, R.
    Lichtenstein, K.
    Novak, R. M.
    Yangco, B.
    Wood, K.
    Durham, M.
    Buchacz, K.
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 2016, 71 (09) : 2654 - 2662