CD4 T-Cell Enumeration in a Field Setting: Evaluation of CyFlow Counter Using the CD4 Easy Count Kit-Dry and Pima CD4 Systems

被引:16
作者
Wade, Djibril [1 ,2 ,3 ]
Diaw, Papa Alassane [1 ]
Daneau, Geraldine [2 ]
Camara, Makhtar [1 ]
Dieye, Tandakha Ndiaye [1 ]
Mboup, Souleymane [1 ]
Kestens, Luc [2 ,3 ]
机构
[1] Le Dantec Univ Teaching Hosp, Immunol Unit, Bacteriol Lab, Dakar, Senegal
[2] Inst Trop Med, Immunol Lab, Dept Biomed Sci, B-2000 Antwerp, Belgium
[3] Univ Antwerp, Dept Biomed Sci, B-2020 Antwerp, Belgium
来源
PLOS ONE | 2013年 / 8卷 / 09期
关键词
HIV-INFECTED INDIVIDUALS; FLOW-CYTOMETRY; PERFORMANCE EVALUATION; ALTERNATIVE METHODS; POINT; LYMPHOCYTES; ANALYZER; BLOOD; COEFFICIENT; CLINICS;
D O I
10.1371/journal.pone.0075484
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background: Flow Cytometry (FCM) is still considered to be the method of choice for accurate CD4 enumeration. However, the use of FCM in developing countries is problematic due to their cost and complexity. Lower-cost technologies have been introduced. We evaluated CyFlow Counter together with its lyophilized reagents, and Pima CD4 in high-temperature area, using FACSCount as reference. Materials and Methods: Whole blood samples were consecutively collected by venipuncture from 111 HIV+ patients and 17 HIV-negative donors. CD4 T-cell enumeration was performed on CyFlow Counter, Pima CD4 and FACSCount. Results: CyFlow Counter and Pima CD4 systems showed good correlation with FACSCount (slope of 0.82 and 0.90, and concordance rho(c) of 0.94 and 0.98, respectively). CyFlow Counter showed absolute or relative biases (LOA) of 263 cells/mm(3) (-245 to 120) or -9.8% (-38.1 to 18.4) respectively, and Pima CD4 showed biases (LOA) of -30 cells/mm(3) (-160 to 101) or -3.5% (-41.0 to 33.9%). CyFlow Counter and Pima CD4 showed respectively 106.7% and 105.9% of similarity with FACSCount. According to WHO-2010 ART initiation threshold of 350 cells/mm(3), CyFlow Counter and Pima CD4 showed respectively sensibility of 100% and 97%, and specificity of 91% and 93%. CyFlow Counter and Pima CD4 were strongly correlated (slope of 1.09 and rho(c) of 0.95). These alternative systems showed good agreement with bias of 33 cells/mm(3) (-132 to 203) or 6.3% (-31.2 to 43.8), and similarity of 104.3%. Conclusion: CyFlow Counter using CD4 easy count kit-dry and Pima CD4 systems can accurately provide CD4 T-cell counts with acceptable agreement to those of FACSCount.
引用
收藏
页数:8
相关论文
共 43 条
[1]   Point-of-care testing [J].
Anderson D.A. ;
Crowe S.M. ;
Garcia M. .
Current HIV/AIDS Reports, 2011, 8 (1) :31-37
[2]  
[Anonymous], 2010, Antiretroviral therapy for HIV infection in adults and adolescents
[3]  
[Anonymous], HIV WHO AFR REG PROG
[4]   A reliable and inexpensive EasyCD4 assay for monitoring HIV-infected individuals in resource-limited settings [J].
Balakrishnan, Pachamuthu ;
Solomon, Suniti ;
Mohanakrishnan, Janardhanan ;
Cecelia, Anitha J. ;
Kumarasamy, Nagalingeswaran ;
Murugavel, Kailapuri G. ;
Venkatakrishnan, Bhavani ;
Solomon, Sunil S. ;
Crowe, Suzanne M. ;
Ganesh, Aylur K. ;
Thyagarajan, Sadras P. ;
Flanigan, Timothy ;
Mayer, Kenneth H. .
JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2006, 43 (01) :23-26
[5]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[6]  
Cassens U, 2004, ANTIVIR THER, V9, P395
[7]   A COEFFICIENT OF AGREEMENT FOR NOMINAL SCALES [J].
COHEN, J .
EDUCATIONAL AND PSYCHOLOGICAL MEASUREMENT, 1960, 20 (01) :37-46
[8]   Multisite Evaluation of a Point-of-Care Instrument for CD4+ T-Cell Enumeration Using Venous and Finger-Prick Blood: The PIMA CD4 [J].
Diaw, Papa Alassane ;
Daneau, Geraldine ;
Coly, Abdoul Aziz ;
Ndiaye, Birahim Pierre ;
Wade, Djibril ;
Camara, Makhtar ;
Mboup, Souleymane ;
Kestens, Luc ;
Dieye, Tandakha Ndiaye .
JAIDS-JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2011, 58 (04) :E103-E111
[9]   Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries [J].
Didier, JM ;
Kazatchkine, MD ;
Demouchy, C ;
Moat, C ;
Diagbouga, S ;
Sepulveda, C ;
Di Lonardo, AM ;
Weiss, L .
JOURNAL OF ACQUIRED IMMUNE DEFICIENCY SYNDROMES, 2001, 26 (02) :193-195
[10]   Evaluation of a flow cytometry method for CD4 T cell enumeration based on volumetric primary CD4 gating using thermoresistant reagents [J].
Dieye, Tandakha Ndiaye ;
Diaw, Papa Alassane ;
Daneau, Geraldine ;
Wade, Djibril ;
Niang, Maguette Sylla ;
Camara, Makhtar ;
Diallo, Abdoul Aziz ;
Kane, Coumba Toure ;
Ndiaye, Halimatou Diop ;
Mbengue, Babacar ;
Dieye, Alioune ;
Kestens, Luc ;
Mboup, Souleymane .
JOURNAL OF IMMUNOLOGICAL METHODS, 2011, 372 (1-2) :7-13