Comparison of near-infrared spectroscopy and tissue Po2 time series in patients after severe head injury and aneurysmal subarachnoid hemorrhage

被引:55
作者
Brawanski, A [1 ]
Faltermeier, R [1 ]
Rothoerl, RD [1 ]
Woertgen, C [1 ]
机构
[1] Univ Regensburg, Dept Neurosurg, D-93053 Regensburg, Germany
关键词
near-infrared spectroscopy (NIRS); rSo(2); tissue Po-2 (tipo(2)); frequency analysis; multitaper analysis; modeling;
D O I
10.1097/00004647-200205000-00012
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Monitoring of local oxygen pressure in brain white matter (tipo(2)) and of local hemoglobin oxygen saturation (rSo(2)) with near-infrared spectroscopy (NIRS) are increasingly employed techniques in neurosurgical intensive care units. Using frequency-based mathematical method,,, the authors sought to ascertain whether both techniques contained similar information. Twelve patient,,; treated in the intensive care unit were included (subarachnoid hemorrhage, n = 3 traumatic brain injury, n = 9). A tipo(2) probe and an NIRS sensor were positioned over the frontal lobe with the most pathologic changes on initial computed tomography scan. The authors calculated coherence of tipo(2) and rSo(2). its overall density distribution, its distribution per data set, and its time evolution. The authors identified a band of significantly correlated frequencies (from 0 to 1.3 x 10(3) Hz) in more than 90% of the data sets for coherence and overall density distribution. Time evolution showed slow but marked changes of significant coherence, By means of spectral analysis the authors show that tipo(2) and rSo(2) signals contain similar information. albeit using completely different registration methodologies.
引用
收藏
页码:605 / 611
页数:7
相关论文
共 18 条
  • [1] [Anonymous], [No title captured]
  • [2] BRILLINGER BR, 1981, TIME SERIES DATA ANA
  • [3] Near-infrared spectroscopy -: not useful to monitor cerebral oxygenation after severe brain injury
    Büchner, K
    Meixensberger, J
    Dings, J
    Roosen, K
    [J]. ZENTRALBLATT FUR NEUROCHIRURGIE, 2000, 61 (02): : 69 - 73
  • [4] Clinical experience with 118 brain tissue oxygen partial pressure catheter probes
    Dings, J
    Meixensberger, J
    Jager, A
    Roosen, K
    [J]. NEUROSURGERY, 1998, 43 (05) : 1082 - 1094
  • [5] Accuracy of a cerebral oximeter in healthy volunteers under conditions of isocapnic hypoxia
    Henson, LC
    Calalang, C
    Temp, JA
    Ward, DS
    [J]. ANESTHESIOLOGY, 1998, 88 (01) : 58 - 65
  • [6] Monitoring of cerebral oxygenation in patients with severe head injuries: Brain tissue PO2 versus jugular vein oxygen saturation
    Kiening, KL
    Unterberg, AW
    Bardt, TF
    Schneider, GH
    Lanksch, WR
    [J]. JOURNAL OF NEUROSURGERY, 1996, 85 (05) : 751 - 757
  • [7] NEAR-INFRARED SPECTROSCOPY USE IN PATIENTS WITH HEAD-INJURY
    KIRKPATRICK, PJ
    SMIELEWSKI, P
    CZOSNYKA, M
    MENON, DK
    PICKARD, JD
    [J]. JOURNAL OF NEUROSURGERY, 1995, 83 (06) : 963 - 970
  • [8] Cerebral oxygenation monitoring by near-infrared spectroscopy is not clinically useful in patients with severe closed-head injury: A comparison with jugular venous bulb oximetry
    Lewis, SB
    Myburgh, JA
    Thornton, EL
    Reilly, PL
    [J]. CRITICAL CARE MEDICINE, 1996, 24 (08) : 1334 - 1338
  • [9] MAAS AIR, 1993, ACTA NEUROCHIR, P50
  • [10] Meixensberger J, 1998, ACT NEUR S, V71, P260