Evaluation of Quantification of HIV-1 RNA Viral Load in Plasma and Dried Blood Spots by Use of the Semiautomated Cobas Amplicor Assay and the Fully Automated Cobas Ampliprep/TaqMan Assay, Version 2.0, in Kisumu, Kenya

被引:21
作者
Ouma, Kenneth N. [1 ]
Basavaraju, Sridhar V. [2 ]
Okonji, Jully A. [1 ]
Williamson, John [3 ]
Thomas, Timothy K. [3 ]
Mills, Lisa A. [3 ]
Nkengasong, John N. [4 ]
Zeh, Clement [3 ]
机构
[1] Kenya Govt Med Res Ctr, Ctr Global Hlth Res, Kisumu, Kenya
[2] Ctr Dis Control & Prevent, HIV Prevent Branch, Div Global HIV AIDS, Ctr Global Hlth, Atlanta, GA USA
[3] Ctr Dis Control & Prevent, Div HIV AIDS Prevent, Kisumu, Kenya
[4] Ctr Dis Control & Prevent, Int Lab Branch, Div Global HIV AIDS, Ctr Global Hlth, Atlanta, GA USA
关键词
VIRUS TYPE-1 RNA; TAQMAN HIV-1; ANTIRETROVIRAL THERAPY; DIAGNOSIS; QUANTITATION; PERFORMANCE; INFECTION; SENSITIVITY;
D O I
10.1128/JCM.03048-12
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
In Kenya, HIV-1 viral load monitoring is commonly performed with the Cobas Amplicor using plasma specimens. Interest is growing in transitioning to real-time PCR (RT-PCR), such as the Cobas Ampliprep/Cobas TaqMan (CAP/CTM), using dried blood spots (DBS). Before implementation, direct evaluation of the two assays using DBS field specimens is required. This study compares the sensitivity, specificity, negative and positive predictive values (NPV and PPV, respectively), concordance, and agreement between HIV-1 viral load measurements using plasma and DBS specimens obtained from 512 HIV-1-infected pregnant females enrolled in the Kisumu Breastfeeding Study and tested with the Cobas Amplicor and CAP/CTM assays. The sensitivity and NPV of viral load detection in DBS specimens were higher with CAP/CTM (sensitivity, 100%; 95% confidence interval [CI], 99.1 to 100.0%; NPV, 100%; 95% CI, 59.0 to 100.0%) than the Cobas Amplicor (sensitivity, 96.6%; 95% CI, 94.3 to 98.1%; NPV, 58.8%; 95% CI, 40.7 to 75.4%). The PPVs were comparable between both assays when using DBS. The specificity of viral load detection in DBS specimens was lower with CAP/CTM (77.8%; 95% CI, 40.0 to 97.2%) than that of the Cobas Amplicor (95.2%; 95% CI, 76.2 to 99.9%). Good concordance and agreement were observed when paired plasma and DBS specimens were tested with both assays. Lower specificity with the CAP/CTM is likely due to proviral HIV-1 DNA amplification and lower detection limits with RT-PCR. However, the CAP/CTM has better sensitivity and higher throughput than the Cobas Amplicor. These findings suggest that DBS may be a suitable alternative to plasma when using RT-PCR, which could increase access to viral load monitoring in resource-limited settings.
引用
收藏
页码:1208 / 1218
页数:11
相关论文
共 41 条
[1]   Improving clinical laboratory efficiency: a time-motion evaluation of the Abbott m2000 RealTime and Roche COBAS AmpliPrep/COBAS TaqMan PCR systems for the simultaneous quantitation of HIV-1 RNA and HCV RNA [J].
Amendola, Alessandra ;
Coen, Sabrina ;
Belladonna, Stefano ;
Pulvirenti, F. Renato ;
Clemens, John M. ;
Capobianchi, M. Rosaria .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2011, 49 (08) :1283-1288
[2]   Correlation between HIV-1 viral load quantification in plasma, dried blood spots, and dried plasma spots using the Roche COBAS Taqman assay [J].
Andreotti, Mauro ;
Pirillo, Maria ;
Guidotti, Giovanni ;
Ceffa, Susanna ;
Paturzo, Giovanna ;
Germano, Paola ;
Luhanga, Richard ;
Chimwaza, David ;
Mancini, Maria Grazia ;
Marazzi, Maria Cristina ;
Vella, Stefano ;
Palombi, Leonardo ;
Giuliano, Marina .
JOURNAL OF CLINICAL VIROLOGY, 2010, 47 (01) :4-7
[3]  
Anema Aranka, 2009, Eur Infect Dis, V3, P41
[4]   Prevention of HIV-1 Infection with Early Antiretroviral Therapy [J].
Cohen, Myron S. ;
Chen, Ying Q. ;
McCauley, Marybeth ;
Gamble, Theresa ;
Hosseinipour, Mina C. ;
Kumarasamy, Nagalingeswaran ;
Hakim, James G. ;
Kumwenda, Johnstone ;
Grinsztejn, Beatriz ;
Pilotto, Jose H. S. ;
Godbole, Sheela V. ;
Mehendale, Sanjay ;
Chariyalertsak, Suwat ;
Santos, Breno R. ;
Mayer, Kenneth H. ;
Hoffman, Irving F. ;
Eshleman, Susan H. ;
Piwowar-Manning, Estelle ;
Wang, Lei ;
Makhema, Joseph ;
Mills, Lisa A. ;
de Bruyn, Guy ;
Sanne, Ian ;
Eron, Joseph ;
Gallant, Joel ;
Havlir, Diane ;
Swindells, Susan ;
Ribaudo, Heather ;
Elharrar, Vanessa ;
Burns, David ;
Taha, Taha E. ;
Nielsen-Saines, Karin ;
Celentano, David ;
Essex, Max ;
Fleming, Thomas R. .
NEW ENGLAND JOURNAL OF MEDICINE, 2011, 365 (06) :493-505
[5]   Comparative frequencies of HIV low-level viremia between real-time viral load assays at clinically relevant thresholds [J].
Do, Tri ;
Duncan, John ;
Butcher, Ann ;
Liegler, Teri .
JOURNAL OF CLINICAL VIROLOGY, 2011, 52 :S83-S89
[6]  
FDA, 2011, COMPLETE LIST OF DON
[7]   Quantitation of human immunodeficiency virus type 1 RNA in plasma by using blood dried on filter paper [J].
Fiscus, SA ;
Brambilla, D ;
Grosso, L ;
Schock, J ;
Cronin, M .
JOURNAL OF CLINICAL MICROBIOLOGY, 1998, 36 (01) :258-260
[8]   Diminishing Availability of Publicly Funded Slots for Antiretroviral Initiation among HIV-Infected ART-Eligible Patients in Uganda [J].
Geng, Elvin H. ;
Bwana, Mwebesa B. ;
Kabakyenga, Jerome ;
Muyindike, Winnie ;
Emenyonu, Nneka I. ;
Musinguzi, Nicholas ;
Mugyenyi, Peter ;
Martin, Jeffrey N. ;
Bangsberg, David R. .
PLOS ONE, 2010, 5 (11)
[9]   High survival and treatment success sustained after two and three years of first-line ART for children in Cambodia [J].
Isaakidis, Petros ;
Raguenaud, Marie-Eve ;
Te, Vantha ;
Tray, Chhraing S. ;
Akao, Kazumi ;
Kumar, Varun ;
Ngin, Sopheak ;
Nerrienet, Eric ;
Zachariah, Rony .
JOURNAL OF THE INTERNATIONAL AIDS SOCIETY, 2010, 13
[10]   Dried blood spots in HIV monitoring: applications in resource-limited settings [J].
Johannessen, Asgeir .
BIOANALYSIS, 2010, 2 (11) :1893-1908