Effect of anodization on corrosion behaviour and biocompatibility of Cp-titanium in simulated body fluid

被引:13
|
作者
Singh, Archana [1 ]
Singh, B. P. [1 ]
Wani, Mohan R. [3 ]
Kumar, Dinesh [4 ]
Singh, J. K. [5 ]
Singh, Vakil [2 ]
机构
[1] Banaras Hindu Univ, Inst Med Sci, Fac Dent Sci, Dept Prosthodont, Varanasi 221005, Uttar Pradesh, India
[2] Banaras Hindu Univ, Inst Technol, Dept Met Engn, Ctr Adv Study, Varanasi 221005, Uttar Pradesh, India
[3] Natl Ctr Cell Sci, Pune 411007, Maharashtra, India
[4] Banaras Hindu Univ, Dept Zool, Fac Sci, Varanasi 221005, Uttar Pradesh, India
[5] Natl Met Lab, Corros & Surface Engn Div, Jamshedpur 831007, Bihar, India
关键词
Corrosion resistance; pitting resistance; anodization; biocompatibility; MG63 osteoblast cells; OXIDE NANOTUBE ARRAYS; ANODIC-OXIDATION; SURFACE; ALLOYS; TI;
D O I
10.1007/s12034-013-0536-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this investigation is to study the effectiveness of anodized surface of commercial purity titanium (Cp-Ti) on its corrosion behaviour in simulated body fluid (SBF) and proliferation of osteoblast cells on it, to assess its potentiality as a process of surface modification in enhancing corrosion resistance and osseointegration of dental implants. Highly ordered nano-porous oxide layer, with nano-sized pores, is developed on the surface of Cp-Ti through electrochemical anodization in the electrolyte of aqueous solution of 0 center dot 5% HF at 15 V for 30 min at 24 A degrees C. The nano-porous feature of the anodized surface is characterized by field-emission scanning electron microscope (FESEM). Pores of some anodized samples are sealed by exposing the anodized surface in boiling water. Corrosion behaviour of the anodized specimen is studied in Ringer's solution at 30 +/- 2 A degrees C, using electrochemical impedance and cyclic polarization technique. Biocompatibility of the anodized surface is accessed using MG63 osteoblast cells. Both corrosion as well as pitting resistance of Cp-Ti in simulated body fluid are found to be highest in the anodized and sealed condition and followed in decreasing order by those of anodized and unanodized ones. Significantly higher MG63 osteoblast cell proliferations are found on the anodized surface than that on the unanodized one. Anodized Cp-Ti develops nano-size surface pores, like that of natural bone. It enhances corrosion and pitting resistance and also the process of osteoblast cell proliferation on Cp-Ti.
引用
收藏
页码:931 / 937
页数:7
相关论文
共 50 条
  • [31] Corrosion behaviour of the porous iron scaffold in simulated body fluid for biodegradable implant application
    Sharma, Pawan
    Pandey, Pulak M.
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 99 : 838 - 852
  • [32] Corrigendum: Combined effect of TiN coating and surface texture on corrosion-wear behavior of selective laser melted CP-titanium in simulated body fluid (Journal of Alloys and Compounds (2020) 816, (S0925838819339131), (10.1016/j.jallcom.2019.152667))
    Zhao, X.
    Liu, H.
    Li, S.
    Wang, X.
    Sheng, Y.
    Zhang, P.
    Li, W.
    Journal of Alloys and Compounds, 2022, 842
  • [33] Anisotropic biaxial creep of textured Cp-titanium tubing: Effect of cold-work
    Murty, KL
    Tanikella, BV
    Kola, RR
    MODELING THE MECHANICAL RESPONSE OF STRUCTURAL MATERIALS, 1998, : 153 - 161
  • [34] Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks' Simulated Body Fluid
    Liu, Shuyue
    Wang, Bing
    Zhang, Peirong
    MATERIALS, 2016, 9 (11):
  • [35] Effect of bicarbonate on biodegradation behaviour of pure magnesium in a simulated body fluid
    Li, Zaichun
    Song, Guang-Ling
    Song, Shizhe
    ELECTROCHIMICA ACTA, 2014, 115 : 56 - 65
  • [36] Functionally graded oxygen-containing coating on CP-titanium for bio-applications: characterization, biocompatibility and tribocorrosion behavior
    Cheraghali, B.
    Ghasemi, H. M.
    Abedini, M.
    Yazdi, R.
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 21 : 104 - 120
  • [37] Effect of deformation twinning on microstructure and texture evolution during cold rolling of CP-titanium
    Chun, YB
    Yu, SH
    Semiatin, SL
    Hwang, SK
    MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 2005, 398 (1-2): : 209 - 219
  • [38] Influence of Tantalum Addition on the Corrosion Passivation of Titanium-Zirconium Alloy in Simulated Body Fluid
    Sherif, El-Sayed M.
    Bahri, Yassir A. A.
    Alharbi, Hamad F. F.
    Ijaz, Muhammad Farzik
    Alnaser, Ibrahim A. A.
    MATERIALS, 2022, 15 (24)
  • [39] Corrosion behavior of plasma electrolytically oxidized gamma titanium aluminide alloy in simulated body fluid
    Rodriguez, L. Lara
    Sundaram, P. A.
    MATERIALS CHEMISTRY AND PHYSICS, 2016, 181 : 67 - 77
  • [40] Oral Factors Affecting Titanium Elution and Corrosion: An In Vitro Study Using Simulated Body Fluid
    Suito, Hideki
    Iwawaki, Yuki
    Goto, Takaharu
    Tomotake, Yoritoki
    Ichikawa, Tetsuo
    PLOS ONE, 2013, 8 (06):