Effect of anodization on corrosion behaviour and biocompatibility of Cp-titanium in simulated body fluid

被引:13
|
作者
Singh, Archana [1 ]
Singh, B. P. [1 ]
Wani, Mohan R. [3 ]
Kumar, Dinesh [4 ]
Singh, J. K. [5 ]
Singh, Vakil [2 ]
机构
[1] Banaras Hindu Univ, Inst Med Sci, Fac Dent Sci, Dept Prosthodont, Varanasi 221005, Uttar Pradesh, India
[2] Banaras Hindu Univ, Inst Technol, Dept Met Engn, Ctr Adv Study, Varanasi 221005, Uttar Pradesh, India
[3] Natl Ctr Cell Sci, Pune 411007, Maharashtra, India
[4] Banaras Hindu Univ, Dept Zool, Fac Sci, Varanasi 221005, Uttar Pradesh, India
[5] Natl Met Lab, Corros & Surface Engn Div, Jamshedpur 831007, Bihar, India
关键词
Corrosion resistance; pitting resistance; anodization; biocompatibility; MG63 osteoblast cells; OXIDE NANOTUBE ARRAYS; ANODIC-OXIDATION; SURFACE; ALLOYS; TI;
D O I
10.1007/s12034-013-0536-2
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The objective of this investigation is to study the effectiveness of anodized surface of commercial purity titanium (Cp-Ti) on its corrosion behaviour in simulated body fluid (SBF) and proliferation of osteoblast cells on it, to assess its potentiality as a process of surface modification in enhancing corrosion resistance and osseointegration of dental implants. Highly ordered nano-porous oxide layer, with nano-sized pores, is developed on the surface of Cp-Ti through electrochemical anodization in the electrolyte of aqueous solution of 0 center dot 5% HF at 15 V for 30 min at 24 A degrees C. The nano-porous feature of the anodized surface is characterized by field-emission scanning electron microscope (FESEM). Pores of some anodized samples are sealed by exposing the anodized surface in boiling water. Corrosion behaviour of the anodized specimen is studied in Ringer's solution at 30 +/- 2 A degrees C, using electrochemical impedance and cyclic polarization technique. Biocompatibility of the anodized surface is accessed using MG63 osteoblast cells. Both corrosion as well as pitting resistance of Cp-Ti in simulated body fluid are found to be highest in the anodized and sealed condition and followed in decreasing order by those of anodized and unanodized ones. Significantly higher MG63 osteoblast cell proliferations are found on the anodized surface than that on the unanodized one. Anodized Cp-Ti develops nano-size surface pores, like that of natural bone. It enhances corrosion and pitting resistance and also the process of osteoblast cell proliferation on Cp-Ti.
引用
收藏
页码:931 / 937
页数:7
相关论文
共 50 条
  • [1] Effect of anodization on corrosion behaviour and biocompatibility of Cp-titanium in simulated body fluid
    ARCHANA SINGH
    B P SINGH
    MOHAN R WANI
    DINESH KUMAR
    J K SINGH
    VAKIL SINGH
    Bulletin of Materials Science, 2013, 36 : 931 - 937
  • [2] The recrystallization behaviour of CP-titanium
    Güçlu, FM
    Çimenoglu, H
    RECRYSTALLIZATION AND GRAIN GROWTH, PTS 1 AND 2, 2004, 467-470 : 459 - 463
  • [3] Combined effect of TiN coating and surface texture on corrosion-wear behavior of selective laser melted CP-titanium in simulated body fluid
    Zhao, Xueyang
    Liu, Hui
    Li, Shuangjian
    Wang, Xiaojian
    Sheng, Yinying
    Zhang, Peng
    Li, Wei
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 816
  • [4] Corrosion behaviour of nitrogen implanted titanium in simulated body fluid
    Arenas, MA
    Tate, TJ
    Conde, A
    De Damborenea, J
    BRITISH CORROSION JOURNAL, 2000, 35 (03): : 232 - 236
  • [5] Corrosion behaviour of cold sprayed titanium coatings in simulated body fluid
    Zhou, X.
    Mohanty, P.
    CORROSION ENGINEERING SCIENCE AND TECHNOLOGY, 2012, 47 (02) : 145 - 154
  • [6] ANN prediction of corrosion behaviour of uncoated and biopolymers coated cp-Titanium substrates
    Kumari, Suman
    Tiyyagura, Hanuma Reddy
    Douglas, Timothy E. L.
    Mohammed, Elbeshary A. A.
    Adriaens, Annemie
    Fuchs-Godec, Regina
    Mohan, M. K.
    Skirtach, Andre G.
    MATERIALS & DESIGN, 2018, 157 : 35 - 51
  • [7] Combined effect of TiN coating and surface texture on corrosion-wear behavior of selective laser melted CP-titanium in simulated body fluid (vol 816, 152667, 2020)
    Zhao, X.
    Liu, H.
    Li, S.
    Wang, X.
    Sheng, Y.
    Zhang, P.
    Li, W.
    JOURNAL OF ALLOYS AND COMPOUNDS, 2020, 842
  • [8] Effect of the anodization frequency and cathodic polarization on the corrosion resistance of CP titanium
    Casanova, L.
    Pedeferri, M. P.
    Diamanti, M., V
    Ormellese, M.
    METALLURGIA ITALIANA, 2021, 113 (06): : 23 - 30
  • [9] Corrosion behaviour of ultra fine grained titanium in simulated body fluid for implant application
    Department of Information and Electronic Materials Engineering, College of Engineering, Paichai University, Daejeon 302-735, Korea, Republic of
    不详
    Trends Biomater. Artif. Organs, 2008, 1 (54-60):
  • [10] Corrosion behaviour of pure magnesium in a simulated body fluid
    Song Guang-Ling
    Song Shi-Zhe
    ACTA PHYSICO-CHIMICA SINICA, 2006, 22 (10) : 1222 - 1226