Minimally invasive sliding hip screw insertion technique

被引:3
|
作者
Khan, Asif Z. [1 ]
Parker, Martyn J. [1 ]
机构
[1] Peterborough City Hosp, Dept Trauma & Orthopaed, Peterborough PE3 9GZ, Cambs, England
关键词
Hip fracture; Extracapsular neck of femur fracture; Sliding hip screw; Minimally invasive; INTERTROCHANTERIC FRACTURES; FIXATION; TRIAL; PLATE;
D O I
10.5301/HIP.2012.9236
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Sliding hip screws (SHS) are commonly used for fixation of extra-capsular hip fractures, and there is increasing use of minimally invasive methods of insertion of such devices. We describe a case series of 579 consecutive patients operated on by the senior author using such a technique. Data were collected prospectively and analysed retrospectively. The technique involves a 5cm incision, retraction of vastus lateralis superiorly by a chain retractor, and use of a SHS clamp to stabilise the plate on the femur. The patients had a mean age of 81 years, surgery time of 43 minutes and hospital stay of 17 days. 77% were female and 35% required a blood transfusion post-operatively. Everyone was mobilised fully weight-bearing post-operatively. Follow-up was at six weeks for radiographic review and then subsequently at one year. The commonest complications were superficial wound infection (1.7%), detachment of the plate (0.9%) and cut-out of the lag screw (0.5%).
引用
收藏
页码:214 / 217
页数:4
相关论文
共 50 条
  • [21] Fatigue failure of the sliding hip screw - clinical and biomechanical analysis
    Necas, Libor
    Hrubina, Maros
    Cibula, Zoltan
    Behounek, Jiri, Jr.
    Krivanek, Stanislav
    Horak, Zdenek
    COMPUTER METHODS IN BIOMECHANICS AND BIOMEDICAL ENGINEERING, 2017, 20 (12) : 1364 - 1372
  • [22] Proximal Cut-Out of the Hip Screw: Cement Augmentation as a Minimally Invasive Rescue Procedure
    Ackermann, O.
    Stanjek, M.
    Ruelander, C.
    Pellengahr, C. von Schulze
    ZEITSCHRIFT FUR ORTHOPADIE UND UNFALLCHIRURGIE, 2012, 150 (05): : 484 - 487
  • [23] Minimally Invasive Revision of a C2 Isthmus Screw
    Kogias, Evangelos
    Klingler, Jan-Helge
    Sircar, Ronen
    Deininger, Martin Hermann
    Hubbe, Ulrich
    JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2013, 74 : E211 - E214
  • [24] Minimally invasive surgery in total hip arthroplasty. Surgical technique of the future?
    Woerner, M.
    Weber, M.
    Lechler, P.
    Sendtner, E.
    Grifka, J.
    Renkawitz, T.
    ORTHOPADE, 2011, 40 (12): : 1068 - +
  • [25] A Technique for the Minimally Invasive, Watson-Jones Approach to Total Hip Arthroplasty
    Deirmengian, Carl A.
    Berger, Richard A.
    OPERATIVE TECHNIQUES IN ORTHOPAEDICS, 2006, 16 (02) : 126 - 134
  • [26] Femoral Medialization, Fixation Failures, and Functional Outcome in Trochanteric Hip Fractures Treated With Either a Sliding Hip Screw or an Intramedullary Nail From Within a Randomized Trial
    Bretherton, Christopher P.
    Parker, Martyn J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2016, 30 (12) : 642 - 646
  • [27] Comparison of a sliding hip screw with a trochanteric lateral support plate to an intramedullary hip screw for fixation of unstable intertrochanteric hip fractures: A Cadaver study
    Bong, MR
    Patel, V
    Iesaka, K
    Egol, KA
    Kummer, FJ
    Koval, KJ
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2004, 56 (04): : 791 - 794
  • [28] Earlier postoperative mobilization with minimally invasive hip hemiarthroplasty
    Preininger, B.
    Jesacher, M.
    Fabsits, E.
    Winkler, T.
    UNFALLCHIRURG, 2011, 114 (04): : 333 - 339
  • [29] Navigated minimally invasive facet fusion during percutaneous lumbar pedicle screw insertion: Technical note
    Liu, Yi Lin
    Mehra, Ratnesh N.
    Chou, Dean
    JOURNAL OF CLINICAL NEUROSCIENCE, 2020, 71 : 257 - 262
  • [30] Minimally Invasive Screw Fixation of Phalangeal Fractures
    Welman, T.
    Miller, R.
    Pahal, G. S.
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2020, 51 (08): : 1919 - 1921