Wavenumber calibration of CCD detector Raman spectrometers controlled by a sinus arm drive

被引:29
作者
Berg, RW
Norbygaard, T
机构
[1] Tech Univ Denmark, Dept Chem, DK-2800 Lyngby, Denmark
[2] Tech Univ Denmark, Dept Phys, Quantum Prot Ctr QUP, DK-2800 Lyngby, Denmark
关键词
instrumentation; Raman spectroscopy; wavenumber scale calibration; CCD detector; reproducibility;
D O I
10.1080/05704920500510786
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The calibration procedures needed for use of dispersive Raman spectrometers have been reviewed. Like other high-precision spectrometers incorporating moving gratings, Raman spectrometers are subject to problems with wavenumber scale accuracy. Commercially available Raman spectrometers of types DILOR-HORIBA LabRam and RENISHAW System 1000 have been examined for wavenumber scale stability, linearity, and reproducibility. For reliable use of the wavenumber data, daily calibration is a necessity. A procedure to examine the linearity of such mechanical drive systems is presented. A new finding was that the examined spectrometers give wavenumber calibration errors that were quite reproducible from day to day at a given temperature in the laboratory but depended markedly on the selected setting of the gratings. Knowledge of this linearity problem is essential for obtaining a reliable calibration. The most correct calibration was obtained by the use of certain "golden settings of the sinus drive at a constant temperature of the laboratory. In this way, the examined spectrometers could be used with better precision, without daily calibration, provided the temperature of the room was constant or corrected for. A procedure for correction of these errors by the software is suggested.
引用
收藏
页码:165 / 183
页数:19
相关论文
共 50 条
[41]   ABSCISSA ERROR-DETECTION AND CORRECTION IN RAMAN-SPECTROSCOPY [J].
SHEN, CB ;
VICKERS, TJ ;
MANN, CK .
APPLIED SPECTROSCOPY, 1992, 46 (05) :772-777
[42]  
Smith E, 2005, MODERN RAMAN SPECTROSCOPY: A PRACTICAL APPROACH, P1
[43]  
STOMMEN DP, 1984, LAB RAMAN SPECTROSCO
[44]   CALCULATION OF RAMAN SHIFT IN VACUUM [J].
STREY, G .
SPECTROCHIMICA ACTA PART A-MOLECULAR SPECTROSCOPY, 1969, A 25 (01) :163-&
[45]  
Striganov A. R., 1968, Tables of Spectral Lines of Neutral and Ionized Atoms
[46]   Calibration of dispersive Raman process analyzers [J].
Tedesco, JM ;
Davis, KL .
ELECTRO-OPTIC, INTEGRATED OPTIC, AND ELECTRONIC TECHNOLOGIES FOR ONLINE CHEMICAL PROCESS MONITORING, 1999, 3537 :200-212
[47]   WAVELENGTH CALIBRATION OF A MULTICHANNEL SPECTROMETER [J].
TSENG, CH ;
FORD, JF ;
MANN, CK ;
VICKERS, TJ .
APPLIED SPECTROSCOPY, 1993, 47 (11) :1808-1813
[48]   Compact Raman spectrometers: Data handling methods [J].
Vickers, TJ ;
Rosen, CA ;
Mann, CK .
APPLIED SPECTROSCOPY, 1996, 50 (08) :1074-1081
[49]   Raman shift calibration of a compact multichannel spectrometer [J].
Vickers, TJ ;
Mann, CK .
APPLIED SPECTROSCOPY, 1999, 53 (12) :1617-1622
[50]   EVALUATION OF POLYNOMIAL FITTING FUNCTIONS FOR USE WITH CCD ARRAYS IN RAMAN-SPECTROSCOPY [J].
WOLLMAN, ST ;
BOHN, PW .
APPLIED SPECTROSCOPY, 1993, 47 (01) :125-126