Fault Diagnosis and Fault-Tolerant Control of DC-link Voltage Sensor for Two-stage Three-Phase Grid-Connected PV Inverters

被引:5
|
作者
Kim, Gwang-Seob [1 ]
Lee, Kyo-Beum [1 ]
Lee, Dong-Choon [2 ]
Kim, Jang-Mok [3 ]
机构
[1] Ajou Univ, Dept Elect & Comp Engn, Suwon 441749, South Korea
[2] Yeungnam Univ, Dept Elect Engn, Taegu, South Korea
[3] Pusan Natl Univ, Dept Elect Engn, Pusan, South Korea
关键词
Fault diagnosis; Fault-tolerant control; Grid-connected inverter; Sensorless control; PV inverters; Deadbeat control; WIND TURBINE; GENERATION SYSTEMS; MPPT CONTROL;
D O I
10.5370/JEET.2013.8.4.752
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper proposes a method for fault diagnosis and fault-tolerant control of DC-link voltage sensor for two-stage three-phase grid-connected PV inverters. Generally, the front-end DC-DC boost converter tracks the maximum power point (MPP) of PV array and the rear-end DC-AC inverter is used to generate a sinusoidal output current and keep the DC-link voltage constant. In this system, a sensor is essential for power conversion. A sensor fault is detected when there is an error between the sensed and estimated values, which are obtained from a DC-link voltage sensorless algorithm. Fault-tolerant control is achieved by using the estimated values. A deadbeat current controller is used to meet the dynamic characteristic of the proposed algorithm. The proposed algorithm is validated by simulation and experiment results.
引用
收藏
页码:752 / 759
页数:8
相关论文
共 50 条
  • [31] Fault-tolerant control of Y-connected three-phase induction motor drives without speed measurement
    Nikpayam, Mehdi
    Ghanbari, Mahmood
    Esmaeli, Abdolreza
    Jannati, Mohammad
    MEASUREMENT, 2020, 149
  • [32] Simple fault-tolerant control of dual three-phase PMSM drives
    Shi P.
    Wang X.
    He M.
    Mao Y.
    Wang Z.
    Dianji yu Kongzhi Xuebao/Electric Machines and Control, 2023, 27 (12): : 117 - 126
  • [33] Open-circuit Fault Diagnosis of Three-phase Inverter for Grid-connected Distributed Generation System
    Fan, Chaodong
    Liu, Yingnan
    Yi, Lingzhi
    10TH ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC 2018), 2018, : 246 - 254
  • [34] Voltage sag influence on controlled three-phase grid-connected inverters according to the Spanish grid code
    Bakkar, Mostafa
    Bogarra, Santiago
    Rolan, Alejandro
    Corcoles, Felipe
    Saura, Jaume
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2020, 14 (10) : 1882 - 1892
  • [35] Research on Unbalance Fault-Tolerant Control Strategy of Modular Multilevel Photovoltaic Grid-Connected Inverter
    Liu, Yiqi
    Li, Danhua
    Jin, Yu
    Wang, Qingbo
    Song, Wenlong
    ENERGIES, 2018, 11 (06):
  • [36] Deadbeat and Repetitive Control for Grid-connected Three-phase Four-leg Inverters
    Tan C.
    Chen Q.
    Zhang L.
    Zhou K.
    Dianli Xitong Zidonghua/Automation of Electric Power Systems, 2018, 42 (18): : 142 - 148
  • [37] Model predictive power control for a fault-tolerant grid-connected converter using reconstructed currents
    Yao, Gang
    Li, Yanyan
    Li, Qiang
    Hu, Shiyang
    Jin, Nan
    IET POWER ELECTRONICS, 2020, 13 (06) : 1181 - 1190
  • [38] Coupling Impedance Modeling Analysis of Grid-Connected Inverters Under Three-Phase Voltage Unbalance
    Liu, Yang
    Yu, Haidong
    Wu, Qihang
    Wang, Bin
    Li, Lisheng
    Liu, Wenbin
    ENERGIES, 2025, 18 (03)
  • [39] Fault Diagnosis of DC-Link Capacitors in Three-Phase AC/DC PWM Converters by Online Estimation of Equivalent Series Resistance
    Pu, Xing-Si
    Thanh Hai Nguyen
    Lee, Dong-Choon
    Lee, Kyo-Beum
    Kim, Jang-Mok
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2013, 60 (09) : 4118 - 4127
  • [40] Fault diagnosis in grid-connected PV NPC inverters by a model-based and data processing combined approach
    Pecina Sanchez, Jose Aagel
    Campos-Delgado, Daniel U.
    Espinoza-Trejo, Diego R.
    Valdez-Fernandez, Andres A.
    De Angelo, Cristian H.
    IET POWER ELECTRONICS, 2019, 12 (12) : 3254 - 3264