A Parametric Study on the Influence of Internal Speckle Patterning for Digital Volume Correlation in X-Ray Tomography Applications

被引:8
作者
Gonzalez, J. [1 ]
Lambros, J. [1 ]
机构
[1] Univ Illinois, Dept Aerosp Engn, Urbana, IL 61801 USA
基金
美国国家科学基金会;
关键词
Digital volume correlation; Internal pattern quality; Mean intensity gradient; PDMS; X-ray microcomputed tomography; Uniaxial compression; MICRO-COMPUTED TOMOGRAPHY; IMAGE CORRELATION; SCANNING TOMOGRAPHY; STRAIN-MEASUREMENTS; CERAMICS;
D O I
10.1007/s40799-016-0145-2
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Use of the Digital Volume Correlation (DVC) technique has grown steadily in the mechanics community as a way of quantifying internal mechanical response of complex microstructures under loading. The DVC technique has been combined with internal imaging methodologies such as X-ray microcomputed tomography (X-ray microCT), confocal microscopy, and photoelasticity enabling many full field studies of bone, foam, rock, polymers, and metals. Despite all these efforts, many DVC limitations remain unknown such as those of "optimal" subset size, step size, and the quality of an internal speckle pattern. Here we investigate in detail the effects of internal speckle patterning on DVC. To help determine the optimum setup for DVC, we develop internal speckle patterns using markers ranging from 5 to 50 mu m particles and study these over different resolution length scales. A correlation of pattern size and quality was determined using baseline (i.e., no deformation) and rigid body motion experiments, resulting in a recommended pattern quality parameter. We then performed a uniaxial compression experiment using the optimal pattern determined from the parametric study where we compare accuracy using DVC calculated strains and displacements with theoretical values. An in situ uniaxial compression test demonstrated DVC capabilities resulting in a 2 % error in strain computations.
引用
收藏
页码:1447 / 1459
页数:13
相关论文
共 50 条
[1]  
AMBROSE J, 1973, BRIT J RADIOL, V46, P148
[2]  
[Anonymous], 2009, IMAGE CORRELATION SH, DOI DOI 10.1007/978-0-387-78747-3
[3]   Evaluation of three-dimensional and two-dimensional full displacement fields of a single edge notch fracture mechanics specimen, in light of experimental data using X-ray tomography [J].
Barranger, Yoann ;
Doumalin, Pascal ;
Dupre, Jean-Christophe ;
Germaneau, Arnaud ;
Hedan, Stephen ;
Valle, Valery .
ENGINEERING FRACTURE MECHANICS, 2009, 76 (15) :2371-2383
[4]  
Baruchel J., 2000, XRAY TOMOGRAPHY MAT
[5]   Methods and applications of digital volume correlation [J].
Bay, B. K. .
JOURNAL OF STRAIN ANALYSIS FOR ENGINEERING DESIGN, 2008, 43 (08) :745-760
[6]   Digital volume correlation: Three-dimensional strain mapping using X-ray tomography [J].
Bay, BK ;
Smith, TS ;
Fyhrie, DP ;
Saad, M .
EXPERIMENTAL MECHANICS, 1999, 39 (03) :217-226
[7]   3D analysis from micro-MRI during in situ compression on cancellous bone [J].
Benoit, Aurelie ;
Guerard, Sandra ;
Gillet, Brigitte ;
Guillot, Genevieve ;
Hild, Francois ;
Mitton, David ;
Perie, Jean-Noel ;
Roux, Stephane .
JOURNAL OF BIOMECHANICS, 2009, 42 (14) :2381-2386
[8]   DIGITAL IMAGE CORRELATION USING NEWTON-RAPHSON METHOD OF PARTIAL-DIFFERENTIAL CORRECTION [J].
BRUCK, HA ;
MCNEILL, SR ;
SUTTON, MA ;
PETERS, WH .
EXPERIMENTAL MECHANICS, 1989, 29 (03) :261-267
[9]   In Situ Experiments with X ray Tomography: an Attractive Tool for Experimental Mechanics [J].
Buffiere, J. -Y. ;
Maire, E. ;
Adrien, J. ;
Masse, J. -P. ;
Boller, E. .
EXPERIMENTAL MECHANICS, 2010, 50 (03) :289-305
[10]   A photocurable poly(dimethylsiloxane) chemistry designed for soft lithographic molding and printing in the nanometer regime [J].
Choi, KM ;
Rogers, JA .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (14) :4060-4061