Dispersive microextraction based on magnetic polypyrrole nanowires for the fast determination of pesticide residues in beverage and environmental water samples

被引:55
作者
Zhao, Qin [1 ]
Lu, Qian [1 ]
Feng, Yu-Qi [1 ]
机构
[1] Wuhan Univ, Dept Chem, Key Lab Analyt Chem Biol & Med, Minist Educ, Wuhan 430072, Peoples R China
基金
中国国家自然科学基金;
关键词
Magnetic polypyrrole nanowires; Pesticides; Magnetic solid phase extraction; Gas chromatography/mass spectrometry; SOLID-PHASE EXTRACTION; CHROMATOGRAPHY-MASS SPECTROMETRY; LIQUID-LIQUID-EXTRACTION; GAS-CHROMATOGRAPHY; MULTIRESIDUE DETERMINATION; RAPID-DETERMINATION; NANOPARTICLES; POLYMER; CARBON; PRECONCENTRATION;
D O I
10.1007/s00216-013-6866-5
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this study, magnetic polypyrrole nanowires (mPPYs) were fabricated via a simple co-mixing method based on an "aggregation-wrap" mechanism. The polypyrrole (PPy) nanowires were synthesized by in situ chemical oxidative polymerization using cetyltrimethylammonium bromide as the "soft template" and the magnetic nanoparticles (MNPs) prepared using solvothermal methods. Typically, when these two nanomaterials were vortically mixed in a solvent, the MNPs were wrapped into the PPy nanowire networks that formed during the aggregation process, leading to the formation of mPPYs which can be separated from the solvent rapidly and conveniently by a magnet. Due to the better permeability, good adsorption ability, and magnetic separability of the resultant material, mPPYs were applied for the enrichment of 11 pesticides including organophosphorus, organochlorine, and pyrethroid using magnetic solid phase extraction (MSPE) to test their feasibility in sample preparation. Several parameters affecting the extraction efficiency were investigated, and under the optimized conditions, a simple and effective method for the determination of pesticide residues was established by coupling with gas chromatography/mass spectrometry (GC/MS) analysis. The whole pretreatment process was rapid and can be accomplished within 15 min. The linearity range of the proposed method was 0.2-10 mu g/L, with correlation coefficients (R) of 0.995-0.999; the limits of quantification for the target compounds were in the range of 0.09-0.29 mu g/L. In addition, an acceptable reproducibility was achieved by evaluating the intra- and inter-day precisions with relative standard deviations of less than 14 and 16 %, respectively. Finally, the established MSPE-GC/MS method was successfully applied for the determination of pesticide residues in beverage teas, juices, and environmental water samples.
引用
收藏
页码:4765 / 4776
页数:12
相关论文
共 50 条
  • [31] In-syringe dispersive liquid-liquid microextraction based on the solidification of ionic liquids for the determination of benzoylurea insecticides in water and tea beverage samples
    Wang, Huazi
    Hu, Lu
    Li, Wanzhen
    Yang, Xiaoling
    Lu, Runhua
    Zhang, Sanbing
    Zhou, Wenfeng
    Gao, Haixiang
    Li, Jing
    TALANTA, 2017, 162 : 625 - 633
  • [32] Vortex assisted-supramolecular solvent based microextraction coupled with spectrophotometric determination of triclosan in environmental water samples
    Mpupa, Anele
    Mashile, Geaneth P.
    Nomngongo, Philiswa N.
    OPEN CHEMISTRY, 2017, 15 (01): : 255 - 262
  • [33] Removal of lead and copper ions from environmental water samples by nanorattle magnetic polypyrrole
    Mehdinia, A.
    Niroumand, R.
    Jabbari, A.
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL SCIENCE AND TECHNOLOGY, 2020, 17 (05) : 2721 - 2730
  • [34] An in situ derivatization combined with magnetic ionic liquid-based fast dispersive liquid-liquid microextraction for determination of biogenic amines in food samples
    Cao, Di
    Xu, Xu
    Xue, Shan
    Feng, Xue
    Zhang, Lei
    TALANTA, 2019, 199 : 212 - 219
  • [35] Determination of urea pesticide residues in vegetable, soil, and water samples
    Berrada, H
    Font, G
    Moltó, JC
    CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2003, 33 (01) : 19 - 41
  • [36] Determination of ultraviolet filters in environmental water samples by temperature-controlled ionic liquid dispersive liquid-phase microextraction
    Zhang, Yufeng
    Lee, Hian Kee
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1271 : 56 - 61
  • [37] A Highly Sensitive Dispersive Microextraction Method with Magnetic Carbon Nanocomposites Coupled with Dispersive Liquid-Liquid Microextraction and Two Miscible Stripping Solvents Followed by GC-MS for Quantification of 16 PAHs in Environmental Samples
    Yazdanfar, Najmeh
    Shamsipur, Mojtaba
    Ghambarian, Mahnaz
    Esrafili, Ali
    CHROMATOGRAPHIA, 2018, 81 (03) : 487 - 499
  • [38] LIQUID CHROMATOGRAPHY-UV DETERMINATION OF HEAVY METAL IONS IN ENVIRONMENTAL SAMPLES USING DISPERSIVE LIQUID-LIQUID MICROEXTRACTION COUPLED WITH MAGNETIC NANOPARTICLES
    Wu, H. Z.
    Meng, L. F.
    APPLIED ECOLOGY AND ENVIRONMENTAL RESEARCH, 2019, 17 (02): : 1571 - 1584
  • [39] Dispersive liquid-liquid microextraction followed by high performance liquid chromatography for determination of phthalic esters in environmental water samples
    Xue, Linke
    Zhang, Dongxia
    Wang, Tiane
    Wang, Xue-Mei
    Du, Xinzhen
    ANALYTICAL METHODS, 2014, 6 (04) : 1121 - 1127
  • [40] Promoted reaction microextraction for determining pesticide residues in environmental water samples using gas chromatography-mass spectrometry
    Biparva, Pourya
    Gorji, Setare
    Hedayati, Elahe
    JOURNAL OF CHROMATOGRAPHY A, 2020, 1612