Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6-10 years follow-up

被引:9
|
作者
Zwartele, Rob E. [2 ]
Olsthoorn, Paul G. M. [2 ]
Poll, Rudolf G. [2 ]
Brand, Ronald [1 ]
Doets, H. Cornelis [2 ]
机构
[1] Leiden Univ, Med Ctr, Dept Med Stat, Leiden, Netherlands
[2] Slotervaart Hosp, Dept Orthopaed Surg, Amsterdam, Netherlands
关键词
Cementless total hip arthroplasty; Osteoarthritis; Inflammatory arthritis; Early complications; Survival;
D O I
10.1007/s00402-008-0731-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction A flattened cup was designed to create a more physiological load transfer to the pelvic bone compared to hemispherical cups, and to allow more bone contact compared to low-profile' spherical cups. To investigate these theoretical advantages and the potential influence of the quality of the acetabular bone, a clinical study was performed in patients with osteoarthritis (OA) and inflammatory arthritis (IA). The aims of the study were (1) to evaluate the fixation of the cup, postoperatively and later when osseous integration should have taken place, (2) to assess perioperative complications such as acetabular fractures and (3) to monitor the polar gap, a potential risk factor for osteolysis. Patients and methods A prospective study was performed on all consecutive OA and IA patients with an indication for primary total hip arthroplasty (THA). Three hundred and nine OA patients (340 hips) and 65 IA patients (76 hips) were included. The acetabular component was the flattened press-fit EPF-PLUS(R) cup, the femoral component the tapered cementless Zweymueller SL-PLUS(R) stem. All revisions and complications were recorded. Clinical and radiographical evaluation was performed on regular basis during 6-10 years. Results The incidence of early loosening of the cup was 0 out of 340 in the OA group and 1 out of 76 in the IA group. The incidence of acetabular fractures was 7 out of 340 in the OA group and 3 out of 76 in the IA group. Failure rate for the acetabular component due to aseptic loosening or osteolysis after 6-10 years was 0% in the OA group and 4.8% in the IA group. In all cases available for follow-up the polar gap had disappeared and full osseous integration had taken place in both the groups. Conclusions This study shows that the flattened press-fit acetabular component creates adequate initial mechanical stability to allow osseous integration and that the cup can be safely used in both OA and IA patients. However, after 6-10 years, in the IA group failure of the cup due to aseptic loosening occurred once and failure due to osteolysis occurred three times, while these type of failures did not occur in the OA group.
引用
收藏
页码:1379 / 1386
页数:8
相关论文
共 21 条
  • [1] Primary total hip arthroplasty with a flattened press-fit acetabular component in osteoarthritis and inflammatory arthritis: a prospective study on 416 hips with 6–10 years follow-up
    Rob E. Zwartelé
    Paul G. M. Olsthoorn
    Rudolf G. Pöll
    Ronald Brand
    H. Cornelis Doets
    Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1379 - 1386
  • [2] Primary Total Hip Arthroplasty in Juvenile Idiopathic Arthritis: Survivorship After a Median Follow-Up of 12 Years
    Warren, Shay I.
    Hwang, Katherine L.
    Lee, Jonathan J.
    Murrietta, Adam J.
    Koltsov, Jayme C. B.
    Goodman, Stuart B.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (06) : 1530 - 1534
  • [3] Total hip arthroplasty in inflammatory arthritis in patients under 35 years. A 7 to 19 year follow-up
    Simon, Jean-Pierre
    Maes, Michael
    Robbens, Evelyne
    Bellemans, Johan
    HIP INTERNATIONAL, 2010, 20 (02) : 163 - 170
  • [4] Effect of Total Hip Arthroplasty with Ceramic Acetabular Component on Clinical, Radiographic and Functional Parameters in Older Patients with Hip Osteoarthritis: Two-Year Follow-Up
    Torini, Alexandre Penna
    Barsotti, Carlos Eduardo
    Andrade, Rodrigo Mantelatto
    Nali, Luiz Henrique da Silva
    Ribeiro, Ana Paula
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (02)
  • [5] Results of custom-fit, noncemented, semiconstrained total elbow arthroplasty for inflammatory arthritis at an average of eighteen years of follow-up
    Cross, Michael B.
    Cicalese, Erin
    Nam, Denis
    McArthur, Benjamin A.
    Lipman, Joseph D.
    Figgie, Mark P.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (09) : 1368 - 1373
  • [6] Progression of osteoarthritis of the knee after unilateral total hip arthroplasty: minimum 10-year follow-up study
    Naoya Umeda
    Hidenobu Miki
    Takashi Nishii
    Hideki Yoshikawa
    Nobuhiko Sugano
    Archives of Orthopaedic and Trauma Surgery, 2009, 129 : 149 - 154
  • [7] Progression of osteoarthritis of the knee after unilateral total hip arthroplasty: minimum 10-year follow-up study
    Umeda, Naoya
    Miki, Hidenobu
    Nishii, Takashi
    Yoshikawa, Hideki
    Sugano, Nobuhiko
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2009, 129 (02) : 149 - 154
  • [8] High Risk of Revision Associated with the L-Cup Titanium Alloy Porous Coated Acetabular Component in Primary Total Hip Arthroplasty: Minimum Follow-Up of 14 Years
    Drobniewski, Marek
    Ruzik, Kacper
    Gonera, Bartosz
    Olewnik, Lukasz
    Borowski, Adam
    Triantafyllou, George
    Borowski, Andrzej
    JOURNAL OF CLINICAL MEDICINE, 2025, 14 (04)
  • [9] Clinical Outcome, Survival and Polyethylene Wear of an Uncemented Total Hip Arthroplasty A 10-to 12-Year Follow-Up Study of 81 Hips
    Rienstra, Wietske
    van der Veen, Hugo C.
    van den Akker-Scheek, Inge
    van Raay, Jos J. A. M.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (08) : 1362 - 1366
  • [10] Total Hip Arthroplasty Using Cementless Grit-Blasted Femoral Component A Minimum 10-Year Follow-Up Study
    Hwang, Kyu-Tae
    Kim, Young-Ho
    Kim, Yee-Suk
    Choi, Il-Yong
    JOURNAL OF ARTHROPLASTY, 2012, 27 (08) : 1554 - 1561