Optimal Contrast of Computed Tomography Portal Venography Using Dual-Energy Computed Tomography

被引:13
作者
Wang, Qi [1 ]
Shi, Gaofeng [1 ]
Liu, Xiang [1 ]
Wu, Runze [2 ]
Wang, Shijie [1 ]
机构
[1] Hebei Med Univ, Clin Hosp 4, Dept Radiol, Shijiazhuang 050011, Hebei, Peoples R China
[2] Siemens Healthcare, Beijing, Peoples R China
关键词
dual-energy computed tomography; portal venography; optimum contrast; data fusion; liver; MULTIDETECTOR CT; HEPATOCELLULAR-CARCINOMA; IMAGE QUALITY; LIVER; ANGIOGRAPHY; ENHANCEMENT; FUSION; SIZE; KVP;
D O I
10.1097/RCT.0b013e31827cd656
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: The objective of this study was to evaluate image quality of computed tomography (CT) portal venography using nonlinear blending technique of dual-energy CT (DECT) in portal phase. Methods: Fifty patients underwent contrast-enhanced abdominal scan with DECT at portal venous phase. The images of 2 energy levels were mixed by a nonlinear blending filter defined by blending center (BC) and blending width (BW) and compared with linear mixing images with a ratio of 0.5. Image quality was evaluated by the images' contrast-to-noise ratios (CNRs) and the grade of visible branches of portal vein (grades 1-6). The BC and BW were optimized for the best CNRs. Results: The portal-to-hepatic contrast was significantly higher when the average of the liver and portal vein CT values was chosen as the BC, and 0 to 20 Hounsfield units were chosen as the BW than when using the default mixing values (80.04 [SD, 28.09] vs 38.55 [SD, 14.49] Hounsfield units, P < 0.001). In the optimized images using the nonlinear mixing technique, the mean CT values for the portal venous system and the CNRs were significantly greater than those of the linear mixing images (P < 0.001). A visible branch grade 5 or greater was assigned to 76% of the patients in the optimized group and 36% of the patients in the default linear mixing group. This difference was significant (P < 0.01). Conclusions: The nonlinear blending technique of DECT can improve the image quality of portal venography and show more branches of portal vein without changing the conventional scan protocol.
引用
收藏
页码:142 / 148
页数:7
相关论文
共 28 条
  • [1] Pilot multi-reader study demonstrating potential for dose reduction in dual energy hepatic CT using non-linear blending of mixed kV image datasets
    Apel, Anja
    Fletcher, Joel G.
    Fidler, Jeff L.
    Hough, David M.
    Yu, Lifeng
    Guimaraes, Luis S.
    Bellemann, Matthias E.
    McCollough, Cynthia H.
    Holmes, David R., III
    Eusemann, Christian D.
    [J]. EUROPEAN RADIOLOGY, 2011, 21 (03) : 644 - 652
  • [2] Multidetector CT:: contributions in liver imaging
    Atasoy, Ç
    Akyar, S
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2004, 52 (01) : 2 - 17
  • [3] Prevalence and types of main and right portal vein branching variations on MDCT
    Atasoy, Cetin
    Ouzyuerek, Elif
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) : 676 - 681
  • [4] Intravenous Contrast Medium Administration and Scan Timing at CT: Considerations and Approaches
    Bae, Kyongtae T.
    [J]. RADIOLOGY, 2010, 256 (01) : 32 - 61
  • [5] Cerebral Computed Tomography Angiography Using a Low Tube Voltage (80 kVp) and a Moderate Concentration of Iodine Contrast Material A Quantitative and Qualitative Comparison With Conventional Computed Tomography Angiography
    Cho, Eun-Suk
    Chung, Tae-Sub
    Oh, Dae Kun
    Choi, Hyun Seok
    Suh, Sang Hyun
    Lee, Hyeon-Kyeong
    Lee, Kyung Hee
    [J]. INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 142 - 147
  • [6] Congenital and acquired anomalies of the portal venous system
    Gallego, C
    Velasco, M
    Marcuello, P
    Tejedor, D
    De Campo, L
    Friera, A
    [J]. RADIOGRAPHICS, 2002, 22 (01) : 141 - 159
  • [7] Goshima S, 2007, AM J ROENTGENOL, V187, pW25
  • [8] Mapping of hepatic vascular anatomy: Dynamic contrast-enhanced parallel MR Imaging compared with 64-detector row CT
    Heilmaier, Christina
    Sutter, Reto
    Lutz, Amelie M.
    Seifert, Burkhardt
    Weishaupt, Dominik
    Marincek, Borut
    Willmann, Juergen K.
    [J]. RADIOLOGY, 2007, 245 (03) : 872 - 880
  • [9] Evaluation of non-linear blending in dual-energy computed tomography
    Holmes, David R., III
    Fletcher, Joel G.
    Apel, Anja
    Huprich, James E.
    Siddiki, Hassan
    Hough, David M.
    Schmidt, Bernhard
    Flohr, Thomas G.
    Robb, Richard
    McCollough, Cynthia
    Wittmer, Michael
    Eusemann, Christian
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 409 - 413
  • [10] Hepatic imaging with multidetector CT
    Ji, H
    McTavish, JD
    Mortele, KJ
    Wiesner, W
    Ros, PR
    [J]. RADIOGRAPHICS, 2001, 21 : S71 - S80