An experimental work on the performance of solar cell cooled by flat heat pipe

被引:22
|
作者
Soliman, Aly M. A. [1 ,2 ]
Hassan, Hamdy [1 ,3 ]
机构
[1] Egypt Japan Univ Sci & Technol E JUST, Energy Resources Engn, Alexandria, Egypt
[2] Benha Univ, Fac Engn, Mech Engn Dept, Cairo, Egypt
[3] Assiut Univ, Fac Engn, Mech Engn Dept, Assiut, Egypt
关键词
Solar cell; Flat heat pipe; Heat sink; Performance; Cooling; PHOTOVOLTAIC MODULE; THERMAL REGULATION; SIMULATION; COLLECTOR; SYSTEM; PV/T; SINK; FLOW;
D O I
10.1007/s10973-020-10102-5
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper introduces an experimental study for concentrating solar cell performance cooled by using flat heat pipe. The cell represents the heat pipe evaporator, and the heat pipe condenser is cooled by using a rectangular finned heat sink. This study is investigated at various heat pipe condenser and adiabatic regions lengths and concentration ratios of the radiation intensity incident on the cell, and for forced and free convection airflow cooling through the finned heat sink. The required radiation energy supplied to the cell is provided by solar simulator. The findings illustrate that cell efficiency and output power increase with increasing the heat pipe condenser and decrease its adiabatic regions' lengths. However, cell efficiency reduces with rising the incident radiation intensity. The heat pipe temperature increases with radiation intensity, but its maximum temperature difference does not change greatly with variation solar intensity. Cooling the cell by heat pipe increases its output power by 24.3% compared to free convection without utilizing heat pipe at incident energy 500 W m(-2). Using forced convection with double condenser length increases the cell output power by about 9.1% compared to one heat sink for free convection at falling radiation intensity 3000 W m(-2).
引用
收藏
页码:1883 / 1892
页数:10
相关论文
共 50 条
  • [21] EXPERIMENTAL-STUDY OF THE PERFORMANCE OF A SOLAR COLLECTOR COOLED BY HEAT PIPES
    HAMMAD, M
    RENEWABLE ENERGY, 1995, 6 (01) : 11 - 15
  • [22] EXPERIMENTAL-STUDY OF THE PERFORMANCE OF A SOLAR COLLECTOR COOLED BY HEAT PIPES
    HAMMAD, M
    ENERGY CONVERSION AND MANAGEMENT, 1995, 36 (03) : 197 - 203
  • [23] Experimental research on flat pulsating heat pipe
    Quan, Li
    Jia, Li
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2010, 31 (06): : 1009 - 1012
  • [24] An Experimental Investigation of Thermal Performance of a Polymer-Based Flat Heat Pipe
    Shi, Bo
    Wang, Yi-Biao
    Shan, Ying-Jie
    HEAT TRANSFER-ASIAN RESEARCH, 2016, 45 (08): : 746 - 757
  • [25] Experimental investigation of thermal performance of metal foam wicked flat heat pipe
    Dhanabal, Somasundaram
    Annamalai, Mani
    Muthusamy, Kamaraj
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 82 : 482 - 492
  • [26] Experimental study on the start up performance of flat plate pulsating heat pipe
    Chaofa Hu
    Li Jia
    Journal of Thermal Science, 2011, 20 : 150 - 154
  • [27] Experimental Study on the Start Up Performance of Flat Plate Pulsating Heat Pipe
    Chaofa Hu and Li Jia School of Mechanical
    JournalofThermalScience, 2011, 20 (02) : 150 - 154
  • [28] Experimental Study on the Start Up Performance of Flat Plate Pulsating Heat Pipe
    Hu, Chaofa
    Jia, Li
    JOURNAL OF THERMAL SCIENCE, 2011, 20 (02) : 150 - 154
  • [29] Experimental study of the influences of inclination angle on flat plate heat pipe performance
    Wang, Chen
    Liu, Zhong-Liang
    Zhang, Guang-Meng
    Zhang, Ming
    Xu, Jia-Shuang
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2012, 33 (08): : 1400 - 1402
  • [30] Simulation and Experimental Investigation of Thermal Performance of a Miniature Flat Plate Heat Pipe
    Boukhanouf, R.
    Haddad, A.
    ADVANCES IN MECHANICAL ENGINEERING, 2013,