The value of image-guided intensity-modulated radiotherapy in challenging clinical settings

被引:8
|
作者
Treece, S. J. [1 ]
Mukesh, M. [1 ]
Rimmer, Y. L. [1 ]
Tudor, S. J. [2 ]
Dean, J. C. [1 ]
Benson, R. J. [1 ]
Gregory, D. L. [1 ]
Horan, G. [1 ]
Jefferies, S. J. [1 ]
Russell, S. G. [1 ]
Williams, M. V. [1 ]
Wilson, C. B. [1 ]
Burnet, N. G. [3 ]
机构
[1] Addenbrookes Hosp, Ctr Oncol, Cambridge, England
[2] Addenbrookes Hosp, Dept Med Phys, Cambridge, England
[3] Univ Cambridge, Addenbrookes Hosp, Dept Oncol, Cambridge CB2 2QQ, England
基金
英国医学研究理事会;
关键词
HELICAL TOMOTHERAPY; PROSTATE-CANCER; NASOPHARYNGEAL CARCINOMA; RADIATION-THERAPY; IMPLEMENTATION; REIRRADIATION; CHEMOTHERAPY; CHORDOMA; OBESITY; IMRT;
D O I
10.1259/bjr.20120278
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To illustrate the wider potential scope of image-guided intensity-modulated radiotherapy (IG-IMRT), outside of the "standard" indications for IMRT. Methods: Nine challenging clinical cases were selected. All were treated with radical intent, although it was accepted that in several of the cases the probability of cure was low. IMRT alone was not adequate owing to the close proximity of the target to organs at risk, the risk of geographical miss, or the need to tighten planning margins, making image-guided radiotherapy an essential integral part of the treatment. Discrepancies between the initial planning scan and the daily on-treatment megavoltage CT were recorded for each case. The three-dimensional displacement was compared with the margin used to create the planning target volume (PTV). Results: All but one patient achieved local control. Three patients developed metastatic disease but benefited from good local palliation; two have since died. A further patient died of an unrelated condition. Four patients are alive and well. Toxicity was low in all cases. Without daily image guidance, the PTV margin would have been insufficient to ensure complete coverage in 49% of fractions. It was inadequate by >3mm in 19% of fractions, and by >5mm in 9%. Conclusion: IG-IMRT ensures accurate dose delivery to treat the target and avoid critical structures, acting as daily quality assurance for the delivery of complex IMRT plans. These patients could not have been adequately treated without image guidance. Advances in knowledge: IG-IMRT can offer improved outcomes in less common clinical situations, where conventional techniques would provide suboptimal treatment.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Image-guided intensity-modulated radiotherapy of prostate cancer
    Rudat, Volker
    Nour, A.
    Hammoud, M.
    Alaradi, A.
    Mohammed, A.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2016, 192 (02) : 109 - 117
  • [2] Toxicity after Intensity-Modulated, Image-Guided Radiotherapy for Prostate Cancer
    Guckenberger, Matthias
    Ok, Sami
    Polat, Buelent
    Sweeney, Reinhart A.
    Flentje, Michael
    STRAHLENTHERAPIE UND ONKOLOGIE, 2010, 186 (10) : 535 - 543
  • [3] CLINICAL EXPERIENCE WITH IMAGE-GUIDED RADIOTHERAPY IN AN ACCELERATED PARTIAL BREAST INTENSITY-MODULATED RADIOTHERAPY PROTOCOL
    Leonard, Charles E.
    Tallhamer, Michael
    Johnson, Tim
    Hunter, Kari
    Howell, Kathryn
    Kercher, Jane
    Widener, Jodi
    Kaske, Terese
    Paul, Devchand
    Sedlacek, Scot
    Carter, Dennis L.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 76 (02): : 528 - 534
  • [4] Practical Aspects of Implementation of Helical Tomotherapy for Intensity-modulated and Image-guided Radiotherapy
    Burnet, N. G.
    Adams, E. J.
    Fairfoul, J.
    Tudor, G. S. J.
    Hoole, A. C. F.
    Routsis, D. S.
    Dean, J. C.
    Kirby, R. D.
    Cowen, M.
    Russell, S. G.
    Rimmer, Y. L.
    Thomas, S. J.
    CLINICAL ONCOLOGY, 2010, 22 (04) : 294 - 312
  • [5] Feasibility of intensity-modulated and image-guided radiotherapy for locally advanced esophageal cancer
    Nguyen, Nam P.
    Jang, Siyoung
    Vock, Jacqueline
    Vincent Vinh-Hung
    Chi, Alexander
    Vos, Paul
    Pugh, Judith
    Vo, Richard A.
    Ceizyk, Misty
    Desai, Anand
    Smith-Raymond, Lexie
    BMC CANCER, 2014, 14
  • [6] Image-guided intensity-modulated radiotherapy for patients with locally advanced gastric cancer: a clinical feasibility study
    Badakhshi, Harun
    Gruen, Arne
    Graf, Reinhold
    Boehmer, Dirk
    Budach, Volker
    GASTRIC CANCER, 2014, 17 (03) : 537 - 541
  • [7] Workload of breast image-guided intensity-modulated radiotherapy delivered with TomoTherapy
    Rosalinda, Ricotti
    Eleonora, Miglietta
    Cristina, Leonardi Maria
    Federica, Cattani
    Samantha, Dicuonzo
    Patricia, Rojas Damaris
    Giulia, Marvaso
    Roberto, Orecchia
    Alicjala, Jereczek-Fossa Barbara
    TUMORI JOURNAL, 2020, 106 (06): : 518 - 523
  • [8] 18F-FDG PET/CT for Image-Guided and Intensity-Modulated Radiotherapy
    Ford, Eric C.
    Herman, Joseph
    Yorke, Ellen
    Wahl, Richard L.
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50 (10) : 1655 - 1665
  • [9] Optimization and quality assurance of an image-guided radiation therapy system for intensity-modulated radiation therapy radiotherapy
    Tsai, Jen-San
    Micaily, Bizhan
    Miyamoto, Curtis
    MEDICAL DOSIMETRY, 2012, 37 (03) : 321 - 333
  • [10] TOXICITY ANALYSIS OF POSTOPERATIVE IMAGE-GUIDED INTENSITY-MODULATED RADIOTHERAPY FOR PROSTATE CANCER
    Nath, Sameer K.
    Sandhu, Ajay P.
    Rose, Brent S.
    Simpson, Daniel R.
    Nobiensky, Polly D.
    Wang, Jia-Zhu
    Millard, Fred
    Kane, Christopher J.
    Parsons, J. Kellogg
    Mundt, Arno J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (02): : 435 - 441