Corneal Densitometry in Healthy Corneas and Its Correlation With Endothelial Morphometry

被引:59
作者
Tekin, Kemal [1 ]
Sekeroglu, Mehmet Ali [1 ]
Kiziltoprak, Hasan [1 ]
Yilmazbas, Pelin [1 ]
机构
[1] Ankara Ulucanlar Eye Training & Res Hosp, Ophthalmol Dept, Ankara, Turkey
关键词
cornea densitometry; corneal cell density; pleomorphism; polymegethism; TRANSPARENCY; KERATOPLASTY; DYSTROPHY; POLYMEGETHISM; MICROSCOPY; MORPHOLOGY; CHILDREN; LENS;
D O I
10.1097/ICO.0000000000001363
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate the correlations between corneal endothelial cell properties and corneal densitometry values and to investigate whether corneal densitometry may be used as an indicator of the health of corneal endothelium. Methods: Two hundred fifty-three eyes were analyzed in this prospective cross-sectional study. Corneal densitometry was measured with densitometry software of Pentacam HR-Scheimpflug corneal topography over a 12-mm diameter of the cornea. Furthermore, corneal endothelial cell properties including cell density (CD), average cell area, SD of the cell area, coefficient of variation (CV) of the cell area, maximum cell area, minimum cell area, and percentage of hexagonal cells (HEX) were measured by a specular microscope. The correlations were calculated using Pearson correlation tests. Results: The average cell area, SD, maximum cell area, and minimum cell area values were not statistically significantly correlated with the corneal densitometry values in any layer or concentric annulus. CD, CV, and HEX were statistically significantly correlated with the corneal densitometry values in all layers and concentric annuli (P < 0.05 for each one). Moreover, CD and HEX were inversely and moderately correlated with total corneal densitometry (r = 20.403, P < 0.001, and r = 20.327, P < 0.001, respectively), whereas the CV was positively and moderately correlated with total corneal densitometry (r = 0.349, P < 0.001). Conclusions: Corneal densitometry might have potential to be used as an indicator of the health of corneal endothelium in the future.
引用
收藏
页码:1336 / 1342
页数:7
相关论文
共 28 条
[1]   Changes in Corneal Densitometry in Patients with Fuchs Endothelial Dystrophy after Endothelial Keratoplasty [J].
Alnawaiseh, Maged ;
Rosentreter, Andre ;
Prokosch, Verena ;
Eveslage, Maria ;
Eter, Nicole ;
Zumhagen, Lars .
CURRENT EYE RESEARCH, 2017, 42 (02) :163-167
[2]   Corneal Densitometry, Central Corneal Thickness, and Corneal Central-to-Peripheral Thickness Ratio in Patients With Fuchs Endothelial Dystrophy [J].
Alnawaiseh, Maged ;
Zumhagen, Lars ;
Wirths, Gabriele ;
Eveslage, Maria ;
Eter, Nicole ;
Rosentreter, Andre .
CORNEA, 2016, 35 (03) :358-362
[3]   Corneal Endothelial Cell Density and Morphology in Healthy Turkish Eyes [J].
Arici, Ceyhun ;
Arslan, Osman Sevki ;
Dikkaya, Funda .
JOURNAL OF OPHTHALMOLOGY, 2014, 2014
[4]   Corneal Haze Determined by Confocal Microscopy 2 Years After Descemet Stripping With Endothelial Keratoplasty for Fuchs Corneal Dystrophy [J].
Baratz, Keith H. ;
McLaren, Jay W. ;
Maguire, Leo J. ;
Patel, Sanjay V. .
ARCHIVES OF OPHTHALMOLOGY, 2012, 130 (07) :868-874
[5]   Corneal Endothelium-Past, Present, and Future [J].
Bourne, William M. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2010, 36 (05) :310-314
[6]   Effect of Pseudoexfoliation on Corneal Transparency [J].
Cankaya, Ali Bulent ;
Tekin, Kemal ;
Inanc, Merve .
CORNEA, 2016, 35 (08) :1084-1088
[7]   A prospective analysis of corneal endothelial polymegethism and cell density in young adult Asians [J].
Doughty, Michael J. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2014, 97 (03) :256-263
[8]  
Enders P, 2017, CORNEA, V36, P470, DOI 10.1097/ICO.0000000000001078
[9]   Comparison of corneal endothelial cell measurements by two non-contact specular microscopes [J].
Gasser, Laura ;
Reinhard, Thomas ;
Boeringer, Daniel .
BMC OPHTHALMOLOGY, 2015, 15
[10]   Two single descriptors of endothelial polymegethism and pleomorphism [J].
Gonzalez-Meijome, Jose Manuel ;
Jorge, Jorge ;
Queiros, Antonio ;
Peixoto-de-Matos, Sofia C. ;
Parafita, Manuel A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2010, 248 (08) :1159-1166