Dose Measurement of Hard X-ray Produced by Damavand Tokamak by Means of LiF:Mg, Cu, P TLDs

被引:7
作者
Pourshahab, B. [1 ]
Rasouli, C. [1 ]
Pooya, S. M. Hosseini [2 ]
Rasouli, H. [1 ]
Sadigzadeh, A. [1 ]
Habibi, H. [1 ]
机构
[1] Nucl Sci & Technol Res Inst, Plasma Phys & Nucl Fus Res Sch, Tehran, Iran
[2] Nucl Sci & Technol Res Inst, Radiat Applicat Res Sch, Tehran, Iran
关键词
Damavand tokamak; Dose; Hard X-ray; LiF:Mg; Cu; P; TLD; PHYSICS;
D O I
10.1007/s10894-012-9593-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Damavand tokamak is the source of soft and hard X-ray by hydrogen working gas in plasma duration time. As such devices are widely used in fusion researches, it is required to comply with radiation protection standards and monitor radiation dose output. In this paper the dose measurement of hard X-rays produced by Damavand tokamak has been done in order to perform the necessary protection arrangement in torus area. All experiments were done by Thermoluminescence crystal dosimeter tools of the type LiF:Mg, Cu, P crystals. The results showed that radiation levels around the torus are very high (in the order of several mSv per shot) and various dose levels in different points (in terms of distance and height of device) imply the anisotropic spatial distribution of measured dose. According to the measurements during 100 shots of Damavand tokamak, the total dose in the shielding room which is 5 m away from torus, is above the permissible level. In order to control personnel safety, it was designed and constructed a lead shielding wall with 5 cm thick and 2 m x 7.5 m dimensions and the performed dosimetry operation after installation of wall shows a mean value of 96.33 % reduction in measured dose due to presence of lead shielding. Thus there will be possibility of doing 25,000 shots/year in safe condition.
引用
收藏
页码:451 / 456
页数:6
相关论文
共 8 条
  • [1] Dose Measurement of Hard X-ray Produced by Damavand Tokamak by Means of LiF:Mg, Cu, P TLDs
    B. Pourshahab
    C. Rasouli
    S. M. Hosseini Pooya
    H. Rasouli
    A. Sadigzadeh
    H. Habibi
    Journal of Fusion Energy, 2013, 32 : 451 - 456
  • [2] Imaging of hard x-ray radiations using gafchromic™dosimetry film in damavand tokamak
    Rasouli C.
    Pourshahab B.
    Plasma Research Express, 2021, 3 (03):
  • [3] Thermoluminescent characteristics of LiF:Mg, Cu, P and CaSO4:Dy for low dose measurement
    Del Sol Fernandez, S.
    Garcia-Salcedo, R.
    Guzman Mendoza, J.
    Sanchez-Guzman, D.
    Ramirez Rodriguez, G.
    Gaona, E.
    Rivera Montalvo, T.
    APPLIED RADIATION AND ISOTOPES, 2016, 111 : 50 - 55
  • [4] Using LiF:Mg, Cu, P TLDs to estimate the absorbed dose to water in liquid water around an 192Ir brachytherapy source
    Lucas, P. Aviles
    Aubineau-Laniece, I.
    Lourenco, V.
    Vermesse, D.
    Cutarella, D.
    MEDICAL PHYSICS, 2014, 41 (01)
  • [5] Environmental gamma-ray dose rate measurement by using ultra-high sensitive LiF:Mg,Cu,Si TLD
    Kim, M. J.
    Kim, S. Y.
    Lee, J. I.
    Kim, J. L.
    Chang, I.
    Hong, D. G.
    RADIATION MEASUREMENTS, 2013, 56 : 248 - 251
  • [6] Measurement of runaway electrons energy by hard X-ray spectroscopy in a small circular cross-section tokamak
    Ghanbari, M. R.
    Ghoranneviss, M.
    Elahi, A. Salar
    Mohamadi, S.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (10): : 789 - 794
  • [7] Tangentially viewing hard X-ray imaging system and its measurement simulation on the HL-2M tokamak
    Cheng, Shikui
    Zhang, Yipo
    Xu, Hongbing
    Zhang, Jie
    Zhan, Xuwen
    Zhu, Yuxuan
    Shi, Zhongbing
    Zhong, Wulv
    FUSION ENGINEERING AND DESIGN, 2023, 193
  • [8] EXPERIMENTAL INVESTIGATION OF THE 100 keV X-RAY DOSE RESPONSE OF THE HIGH-TEMPERATURE THERMOLUMINESCENCE IN LIF:MG,TI (TLD-100): THEORETICAL INTERPRETATION USING THE UNIFIED INTERACTION MODEL
    Livingstone, J.
    Horowitz, Y. S.
    Oster, L.
    Datz, H.
    Lerch, M.
    Rosenfeld, A.
    Horowitz, A.
    RADIATION PROTECTION DOSIMETRY, 2010, 138 (04) : 320 - 333