Evaluation of a rapid automated assay for analysis of von Willebrand ristocetin cofactor activity

被引:19
|
作者
Strandberg, K
Lethagen, S
Andersson, K
Carlson, A
Hillarp, A [1 ]
机构
[1] Lund Univ, Dept Clin Chem, Malmo Univ Hosp, S-20502 Malmo, Sweden
[2] Lund Univ, Dept Coagulat Disorders, Malmo Univ Hosp, S-20502 Malmo, Sweden
关键词
von Willebrand factor; von Willebrand disease; von Willebrand factor ristocetin cofactor activity; automation; method evaluation;
D O I
10.1177/107602960601200110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A commercially available turbidometric assay has been evaluated for the measurement of von Willebrand factor ristocetin cofactor activity (VWF:RCo). The assay is simple, rapid, and can be cost-effectively performed on automated coagulation analyzers. This study's aim is to illustrate the performance of the automated VWF:RCo assay and its capacity to identify patients with von Willebrand disease (VWD). By direct comparison with a conventional VWF:RCo assay, performed on an aggregometer, the concordance between the two assays was 96%. With minor modifications, the automated assay showed a detection level of 0.03 kIU/L with linearity to 2.00 kIU/L. The imprecision of the automated assay was reduced compared to the conventional assay procedure with CV of 6.8% at the 1.00 kIU/L level and 8.6% at the 0.30 kIU/L level. The automated VWF:RCo assay was also suitable as a screening test to detect VWD in patients investigated for the cause of an increased bleeding tendency. In this situation the automated VWF:RCo assay was tested simultaneously with an automated immunoassay for von Willebrand antigen. Receiver operating curves for the diagnosis of VWD showed a greater area under the curve for the automated VWF:RCo assay compared to the immunoassay, 0.98 vs. 0.94, although the difference did not reach significance. In conclusion, the modified automated VWF:RCo assay shows better precision, lower detection limit, is faster to perform with a lower cost per test compared to the conventional aggregometer based VWF:RCo activity method and is an alternative to an antigen immunoassay as a screening test for VWD.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 50 条
  • [1] Evaluation of an automated platelet-based assay of von Willebrand ristocetin cofactor activity
    Lawrie, A. S.
    Mackie, I. J.
    Peyvandi, F.
    Machin, S. J.
    Peyvandi, F.
    Scully, M. A.
    BRITISH JOURNAL OF HAEMATOLOGY, 2010, 149 : 33 - 33
  • [2] Validation of an automated assay to determine activity of ristocetin cofactor of von Willebrand factor
    Duboscq, Cristina
    Martinuzzo, Marta
    Manuel Ceresetto, Juan
    Carlos Otaso, Juan
    Barrera, Luis
    Maria Oyhamburu, Jose
    Stemmelin, German
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2016, 50 (02):
  • [3] A rapid, automated VWF ristocetin cofactor activity assay improves reliability in the diagnosis of Von Willebrand disease
    Bowyer, Annette E.
    Shepherd, Fiona
    Kitchen, Stephen
    Makris, Michael
    THROMBOSIS RESEARCH, 2011, 127 (04) : 341 - 344
  • [4] Comparison of a new automated von Willebrand factor activity assay with an aggregation von Willebrand ristocetin cofactor activity assay for the diagnosis of von Willebrand disease
    De Vleeschamer, An
    Devreese, Katrien
    BLOOD COAGULATION & FIBRINOLYSIS, 2006, 17 (05) : 353 - 358
  • [5] Evaluation of an automated von Willebrand Ristocetin cofactor assay on the Behring Coagulation Timer.
    Barber, J
    Newlin, F
    Ens, G
    Macy, P
    BLOOD, 1997, 90 (10) : 3118 - 3118
  • [6] Evaluation of an automated von Willebrand factor activity assay without ristocetin
    Sfaxi, Amine
    Borgi, Wijden
    Ben Lakhal, Fatma
    Selem, Sarra Fekih
    Gouider, Emna
    HAEMOPHILIA, 2022, 28 : 93 - 93
  • [7] Validation of improved performance characteristics for the automated von Willebrand factor ristocetin cofactor activity assay
    Favaloro, E. J.
    Mohammed, S.
    McDonald, J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2010, 8 (12) : 2842 - 2844
  • [8] Evaluation of two automated methods for measurement of the ristocetin cofactor activity of von Willebrand factor
    Miller, CH
    Platt, SJ
    Daniele, C
    Kaczor, D
    THROMBOSIS AND HAEMOSTASIS, 2002, 88 (01) : 56 - 59
  • [9] Evaluation of an automated method for the measurement of Ristocetin cofactor activity of von Willebrand factor (VWF:RCo)
    Fortune, H.
    Rafferty, M.
    O'Connell, N.
    O'Donnell, J.
    Byrne, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 919 - 920
  • [10] A comparative evaluation of two new automated assays for von Willebrand factor ristocetin cofactor activity and von Willebrand factor antigen
    Stufano, F.
    Lawrie, A. S.
    La Marca, S.
    Canciani, M. T.
    Franchi, F.
    Cozzi, G.
    Baronciani, L.
    Peyvandi, F.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2013, 11 : 682 - 682