Evaluation of a rapid automated assay for analysis of von Willebrand ristocetin cofactor activity

被引:19
作者
Strandberg, K
Lethagen, S
Andersson, K
Carlson, A
Hillarp, A [1 ]
机构
[1] Lund Univ, Dept Clin Chem, Malmo Univ Hosp, S-20502 Malmo, Sweden
[2] Lund Univ, Dept Coagulat Disorders, Malmo Univ Hosp, S-20502 Malmo, Sweden
关键词
von Willebrand factor; von Willebrand disease; von Willebrand factor ristocetin cofactor activity; automation; method evaluation;
D O I
10.1177/107602960601200110
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A commercially available turbidometric assay has been evaluated for the measurement of von Willebrand factor ristocetin cofactor activity (VWF:RCo). The assay is simple, rapid, and can be cost-effectively performed on automated coagulation analyzers. This study's aim is to illustrate the performance of the automated VWF:RCo assay and its capacity to identify patients with von Willebrand disease (VWD). By direct comparison with a conventional VWF:RCo assay, performed on an aggregometer, the concordance between the two assays was 96%. With minor modifications, the automated assay showed a detection level of 0.03 kIU/L with linearity to 2.00 kIU/L. The imprecision of the automated assay was reduced compared to the conventional assay procedure with CV of 6.8% at the 1.00 kIU/L level and 8.6% at the 0.30 kIU/L level. The automated VWF:RCo assay was also suitable as a screening test to detect VWD in patients investigated for the cause of an increased bleeding tendency. In this situation the automated VWF:RCo assay was tested simultaneously with an automated immunoassay for von Willebrand antigen. Receiver operating curves for the diagnosis of VWD showed a greater area under the curve for the automated VWF:RCo assay compared to the immunoassay, 0.98 vs. 0.94, although the difference did not reach significance. In conclusion, the modified automated VWF:RCo assay shows better precision, lower detection limit, is faster to perform with a lower cost per test compared to the conventional aggregometer based VWF:RCo activity method and is an alternative to an antigen immunoassay as a screening test for VWD.
引用
收藏
页码:61 / 67
页数:7
相关论文
共 14 条
[1]   Von Willebrand factor collagen binding activity in the diagnosis of von Willebrand disease: an alternative to ristocetin co-factor activity? [J].
Casonato, A ;
Pontara, E ;
Bertomoro, A ;
Sartorello, F ;
Cattini, MG ;
Girolami, A .
BRITISH JOURNAL OF HAEMATOLOGY, 2001, 112 (03) :578-583
[2]   Laboratory assessment as a critical component of the appropriate diagnosis and sub-classification of von Willebrand's disease [J].
Favaloro, EJ .
BLOOD REVIEWS, 1999, 13 (04) :185-204
[3]  
Favaloro EJ, 2002, THROMB HAEMOSTASIS, V87, P466
[4]   Diagnosis and management of von Willebrand disease [J].
Federici, AB ;
Mannucci, PM .
HAEMOPHILIA, 1999, 5 :28-37
[5]  
HOWARD MA, 1971, THROMB DIATH HAEMOST, V26, P362
[6]   METHOD FOR ASSAYING VON WILLEBRAND FACTOR (RISTOCETIN COFACTOR) [J].
MACFARLANE, DE ;
STIBBE, J ;
KIRBY, EP ;
ZUCKER, MB ;
GRANT, RA ;
MCPHERSON, J .
THROMBOSIS ET DIATHESIS HAEMORRHAGICA, 1975, 34 (01) :306-308
[7]  
Miller CH, 2002, THROMB HAEMOSTASIS, V88, P56
[8]  
Murdock PJ, 1997, THROMB HAEMOSTASIS, V78, P1272
[9]   von Willebrand disease: still an intriguing disorder in the era of molecular medicine [J].
Rodeghiero, F .
HAEMOPHILIA, 2002, 8 (03) :292-300
[10]   Congenital von Willebrand disease type I: definition, phenotypes, clinical and laboratory assessment [J].
Rodeghiero, F ;
Castaman, G .
BEST PRACTICE & RESEARCH CLINICAL HAEMATOLOGY, 2001, 14 (02) :321-335