Comparison of Noninvasive Blood Pressure Measurements in Patients With Atrial Fibrillation

被引:30
|
作者
Anastas, Zoe M. [1 ]
Jimerson, Elnora [1 ]
Garolis, Salomeja [1 ]
机构
[1] Providence Portland Med Ctr, Portland, OR 97213 USA
关键词
automated BP; BP; manual BP; sphygmomanometer; technology assessment;
D O I
10.1097/01.JCN.0000338935.71285.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Research Objective: Limited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation. Subjects and Methods: In a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05. Results: 53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t(52) = 3.51, P =.0009) and for heart rate differences between the automated BP device and the cardiac monitor (t(52) = 2.4, P =.0217). Conclusion: This study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.
引用
收藏
页码:519 / 524
页数:6
相关论文
共 48 条
  • [41] Systolic blood pressure and the risk of kidney replacement therapy and mortality in patients with chronic kidney disease stage 4-5
    Chavez-Iniguez, Jonathan S.
    Zaragoza, Jose J.
    Camacho-Guerrero, Jahir R.
    Villavicencio-Ceron, Vanessa
    Valdez-Ortiz, Rafael
    Huerta-Orozco, Ana E.
    Chavez-Alonso, Gael
    Oliva-Martinez, Ana E.
    Diaz-Villavicencio, Bladimir
    Calderon-Garcia, Clementina E.
    Gonzalez-Barajas, Jose D.
    Arizaga-Napoles, Manuel
    De La Vega-Mendez, Frida M.
    Gomez-Fregoso, Juan A.
    Rodriguez-Garcia, Francisco G.
    Navarro-Blackaller, Guillermo
    Medina-Gonzalez, Ramon
    Alcantar-Vallin, Luz
    Garcia-Garcia, Guillermo
    KIDNEY & BLOOD PRESSURE RESEARCH, 2023, 48 (01) : 556 - 567
  • [42] Assessment of Achieved Clinic and Ambulatory Blood Pressure Recordings and Outcomes During Treatment in Hypertensive Patients With CKD: A Multicenter Prospective Cohort Study
    Minutolo, R.
    Gabbai, Francis B.
    Agarwal, Rajiv
    Chiodini, Paolo
    Borrelli, Silvio
    Bellizzi, Vincenzo
    Nappi, Felice
    Stanzione, Giovanna
    Conte, Giuseppe
    De Nicola, Luca
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2014, 64 (05) : 744 - 752
  • [43] Determinants of the limits of agreement between the sphygmomanometer and the SpaceLabs 90207 device for blood pressure measurement in healthy volunteers and insulin-dependent diabetic patients
    van Ittersum, FJ
    Wijering, RMJ
    Lambert, J
    Donker, AJM
    Stehouwer, CDA
    JOURNAL OF HYPERTENSION, 1998, 16 (08) : 1125 - 1130
  • [44] Validation of the Omron HEM-650 wrist blood pressure device using the British Hypertension Society protocol in emergency patients in Hong Kong
    Hung, Kevin K. C.
    Lai, W. Y.
    Cocks, Robert A.
    Rainer, Timothy H.
    Graharn, Colin A.
    EMERGENCIAS, 2015, 27 (05): : 313 - 315
  • [45] Association Between Systolic Blood Pressure Variability and Major Adverse Cardiovascular Events in Korean Patients With Chronic Kidney Disease: Findings From KNOW-CKD
    Park, Cheol Ho
    Kim, Hyung Woo
    Joo, Young Su
    Park, Jung Tak
    Chang, Tae Ik
    Yoo, Tae-Hyun
    Park, Sue Kyung
    Chae, Dong-Wan
    Chung, Wookyung
    Kim, Yong-Soo
    Oh, Kook-Hwan
    Kang, Shin-Wook
    Han, Seung Hyeok
    JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2022, 11 (11):
  • [46] Association Between Blood Pressure, Glomerular Filtration Rate, and Serum Thyroid-Stimulating Hormone Levels in Hypothyroid Patients: A Retrospective Single-Center Study br
    Alsulami, Manal O.
    Alharbi, Nada M.
    Alsulami, Dania W.
    Almaghrabi, Sahar J.
    Albaradei, Hadeel A.
    Alhozali, Amani M.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (09)
  • [47] Evaluation of liver function biomarkers, blood pressure, and anthropometric parameters among chronic kidney disease patients: Laboratory-based cross-sectional study in Northwest Ethiopia
    Agidew, Melaku Mekonnen
    Abebe, Endeshaw Chekol
    Muche, Zelalem Tilahun
    Mengstie, Misganaw Asmamaw
    Mulu, Anemut Tilahun
    Admasu, Fitalew Tadele
    Teklemariam, Awgichew Behaile
    Zewde, Edgiet Abebe
    Temesgen, Gelagey Baye
    Ayele, TeklieMengie
    Kassie, Achenef Bogale
    Baye, Nega Dagnew
    Dejenie, Tadesse Asmamaw
    METABOLISM OPEN, 2023, 19
  • [48] Validation of the Microlife BP A3 PC upper arm blood pressure monitor in patients with diabetes mellitus according to the ANSI/AAMI/ISO 81060-2:2013 protocol
    Beime, Beate
    Krueger, Ralf
    Hammel, Gertrud
    Bramlage, Peter
    Deutsch, Cornelia
    BLOOD PRESSURE MONITORING, 2018, 23 (01) : 52 - 57