Comparison of Noninvasive Blood Pressure Measurements in Patients With Atrial Fibrillation

被引:30
|
作者
Anastas, Zoe M. [1 ]
Jimerson, Elnora [1 ]
Garolis, Salomeja [1 ]
机构
[1] Providence Portland Med Ctr, Portland, OR 97213 USA
关键词
automated BP; BP; manual BP; sphygmomanometer; technology assessment;
D O I
10.1097/01.JCN.0000338935.71285.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Research Objective: Limited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation. Subjects and Methods: In a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05. Results: 53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t(52) = 3.51, P =.0009) and for heart rate differences between the automated BP device and the cardiac monitor (t(52) = 2.4, P =.0217). Conclusion: This study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.
引用
收藏
页码:519 / 524
页数:6
相关论文
共 48 条
  • [21] The impact of blood pressure measurement methods on the assessment of differences in blood pressure levels between patients with normoalbuminuric type 1 diabetes and healthy controls
    G Vervoort
    JFM Wetzels
    JA Lutterman
    JHM Berden
    Th Thien
    P Smits
    Journal of Human Hypertension, 1999, 13 : 117 - 122
  • [22] The impact of blood pressure measurement methods on the assessment of differences in blood pressure levels between patients with normoalbuminuric type 1 diabetes and healthy controls
    Vervoort, G
    Wetzels, JFM
    Lutterman, JA
    Berden, JHM
    Thien, T
    Smits, P
    JOURNAL OF HUMAN HYPERTENSION, 1999, 13 (02) : 117 - 122
  • [23] A Comparison of Non-Invasive Blood Pressure Measurement Strategies with Intra-Arterial Measurement
    Rebesco, Matthew R.
    Pinkston, M. Cornelia
    Smyrnios, Nicholas A.
    Weisberg, Stacy N.
    PREHOSPITAL AND DISASTER MEDICINE, 2020, 35 (05) : 516 - 523
  • [24] Validation of Blood Pressure Measurement Using a Smartwatch in Patients With Parkinson's Disease
    Ahn, Jong Hyeon
    Song, Joomee
    Choi, Inyoung
    Youn, Jinyoung
    Cho, Jin Whan
    FRONTIERS IN NEUROLOGY, 2021, 12
  • [25] Comparing Automated Office Blood Pressure Readings With Other Methods of Blood Pressure Measurement for Identifying Patients With Possible Hypertension A Systematic Review and Meta-analysis
    Roerecke, Michael
    Kaczorowski, Janusz
    Myers, Martin G.
    JAMA INTERNAL MEDICINE, 2019, 179 (03) : 351 - 362
  • [26] Blood pressure monitoring during arrhythmia: agreement between automated brachial cuff and intra-arterial measurements
    Lakhal, K.
    Ehrmann, S.
    Martin, M.
    Faiz, S.
    Reminiac, F.
    Cinotti, R.
    Capdevila, X.
    Asehnoune, K.
    Blanloeil, Y.
    Rozec, B.
    Boulain, T.
    BRITISH JOURNAL OF ANAESTHESIA, 2015, 115 (04) : 540 - 549
  • [27] Guiding Hypertension Management Using Different Blood Pressure Monitoring Strategies (GYMNs study): comparison of three different blood pressure measurement methods: study protocol for a randomized controlled trial
    Hao-Min Cheng
    Shih-Hsien Sung
    Chen-Huan Chen
    Wen-Chung Yu
    Shu-Mei Yang
    Chao-Yu Guo
    Shao-Yuan Chuang
    Chern-En Chiang
    Trials, 20
  • [28] Guiding Hypertension Management Using Different Blood Pressure Monitoring Strategies (GYMNs study): comparison of three different blood pressure measurement methods: study protocol for a randomized controlled trial
    Cheng, Hao-Min
    Sung, Shih-Hsien
    Chen, Chen-Huan
    Yu, Wen-Chung
    Yang, Shu-Mei
    Guo, Chao-Yu
    Chuang, Shao-Yuan
    Chiang, Chern-En
    TRIALS, 2019, 20
  • [29] Benefits of continuous positive airway pressure on blood pressure in patients with hypertension and obstructive sleep apnea: a meta-analysis
    Shang, Wenli
    Zhang, Yingying
    Liu, Lu
    Chen, Fenfen
    Wang, Guizuo
    Han, Dong
    HYPERTENSION RESEARCH, 2022, 45 (11) : 1802 - 1813
  • [30] Effect of continuous positive airway pressure on blood pressure in hypertensive patients with coronary artery bypass grafting and obstructive sleep apnea
    Dong, Yumei
    Dai, Yingnan
    Wei, Guoqian
    Cha, Li
    Li, Xueqi
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL MEDICINE, 2014, 7 (11): : 4308 - 4315