Comparison of Noninvasive Blood Pressure Measurements in Patients With Atrial Fibrillation

被引:30
|
作者
Anastas, Zoe M. [1 ]
Jimerson, Elnora [1 ]
Garolis, Salomeja [1 ]
机构
[1] Providence Portland Med Ctr, Portland, OR 97213 USA
关键词
automated BP; BP; manual BP; sphygmomanometer; technology assessment;
D O I
10.1097/01.JCN.0000338935.71285.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Research Objective: Limited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation. Subjects and Methods: In a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05. Results: 53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t(52) = 3.51, P =.0009) and for heart rate differences between the automated BP device and the cardiac monitor (t(52) = 2.4, P =.0217). Conclusion: This study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.
引用
收藏
页码:519 / 524
页数:6
相关论文
共 48 条
  • [1] Detection of Atrial Fibrillation Using a Home Blood Pressure Monitor
    Balanis, Thomas
    Sanner, Bernd
    VASCULAR HEALTH AND RISK MANAGEMENT, 2021, 17 : 407 - 414
  • [2] Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation
    Stergiou, G. S.
    Karpettas, N.
    Protogerou, A.
    Nasothimiou, E. G.
    Kyriakidis, M.
    JOURNAL OF HUMAN HYPERTENSION, 2009, 23 (10) : 654 - 658
  • [3] Diagnostic accuracy of an oscillometric blood pressure monitor for atrial fibrillation screening
    Li, Linyi
    Bing, Sen
    Liu, Kui
    Jiang, Jun
    Zhang, Jieqiong
    Chen, Changsheng
    Wan, Yi
    BLOOD PRESSURE MONITORING, 2023, 28 (03) : 144 - 148
  • [4] Comparison of Microlife BP A200 Plus and Omron M6 Blood Pressure Monitors to Detect Atrial Fibrillation in Hypertensive Patients
    Marazzi, Giuseppe
    Iellamo, Ferdinando
    Volterrani, Maurizio
    Lombardo, Mauro
    Pelliccia, Francesco
    Righi, Daniela
    Grieco, Fabrizia
    Cacciotti, Luca
    Iaia, Luigi
    Caminiti, Giuseppe
    Rosano, Giuseppe
    ADVANCES IN THERAPY, 2012, 29 (01) : 64 - 70
  • [5] Differences in Manual and Automatic Blood Pressures in Telemetry Patients With Atrial Fibrillation
    Collins, Melissa
    Cummings, Adam
    Skaggs, Casie
    Weller, Robyn
    Cronin, Sherill Nones
    DIMENSIONS OF CRITICAL CARE NURSING, 2013, 32 (05) : 262 - 265
  • [6] Agreement Between Automated and Human Measurements of Heart Rate in Patients With Atrial Fibrillation
    Lin, Ting-Tse
    Wang, Chia-Ling
    Liao, Min-Tsun
    Lai, Chao-Lun
    JOURNAL OF CARDIOVASCULAR NURSING, 2018, 33 (05) : 492 - 499
  • [7] Measurement reliability of automated oscillometric blood pressure monitor in the elderly with atrial fibrillation: a systematic review and meta-analysis
    Park, Seong-Hi
    Choi, Yun-Kyoung
    BLOOD PRESSURE MONITORING, 2020, 25 (01) : 2 - 12
  • [8] Korotkoff sound versus oscillometric cuff sphygmomanometers: comparison between auscultatory and DynaPulse blood pressure measurements
    Chio, Shiu-Shin
    Urbina, Elaine M.
    LaPointe, Jeffery
    Tsai, Jeffrey
    Berenson, Gerald S.
    JOURNAL OF THE AMERICAN SOCIETY OF HYPERTENSION, 2011, 5 (01) : 12 - 20
  • [9] Policy Statement of the World Hypertension League on Noninvasive Blood Pressure Measurement Devices and Blood Pressure Measurement in the Clinical or Community Setting
    Campbell, Norm R. C.
    Berbari, Adel E.
    Cloutier, Lyne
    Gelfer, Mark
    Kenerson, John G.
    Khalsa, Tej K.
    Lackland, Daniel T.
    Lemogoum, Daniel
    Mangat, Birinder K.
    Mohan, Sailesh
    Myers, Martin G.
    Niebylski, Mark L.
    O'Brien, Eoin
    Stergiou, George S.
    Veiga, Eugenia Velludo
    Zhang, Xin-Hua
    JOURNAL OF CLINICAL HYPERTENSION, 2014, 16 (05) : 320 - 322
  • [10] Blood pressure measurements in epidemiological surveys - Time to change?
    Hense, HW
    Stieber, J
    Kuch, B
    Keil, U
    ZEITSCHRIFT FUR KARDIOLOGIE, 1996, 85 : 66 - 70