Comparison of Noninvasive Blood Pressure Measurements in Patients With Atrial Fibrillation

被引:30
作者
Anastas, Zoe M. [1 ]
Jimerson, Elnora [1 ]
Garolis, Salomeja [1 ]
机构
[1] Providence Portland Med Ctr, Portland, OR 97213 USA
关键词
automated BP; BP; manual BP; sphygmomanometer; technology assessment;
D O I
10.1097/01.JCN.0000338935.71285.36
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and Research Objective: Limited research is available on the accuracy of automatic blood pressure (BP) measurement devices in patients with irregular rhythms. The purpose of this study was to examine the agreement between different methods for noninvasive BP measurement in patients with atrial fibrillation. Subjects and Methods: In a convenience sample of hospitalized patients with atrial fibrillation, a method-comparison study design was used to examine the agreement between 2 noninvasive devices for BP measurement (manual, automated). Blood pressure was obtained sequentially, with each device following manufacturer's directions and American Heart Association guidelines for BP determination and with BP order determined by random assignment. Heart rate and rhythm were determined from a continuous electrocardiographic monitoring. Heart rate was also recorded from the automated BP device. Differences and limits of agreement between the automated and reference standard (manual) BP devices were calculated and graphed according to the Bland-Altman method. Student t test was used to test differences in BP obtained with the 2 devices, as well as heart rate differences between the electrocardiographic monitor and automated BP device. The level of significance for all tests was set at 0.05. Results: 53 participants were observed. Bland-Altman analysis found a bias plus/minus precision of -0.91 +/- 11.4 mm Hg for systolic BP and 3.3 +/- 6.9 mm Hg for diastolic BP. A significant difference was found for the diastolic BP obtained with the automated device and with that of the manual device (t(52) = 3.51, P =.0009) and for heart rate differences between the automated BP device and the cardiac monitor (t(52) = 2.4, P =.0217). Conclusion: This study confirms that in the presence of irregular cardiac rhythms, diastolic BP and heart rate cannot reliably be measured with an automated BP device.
引用
收藏
页码:519 / 524
页数:6
相关论文
共 28 条
[1]  
*AAMI, 2003, PUBL AAMI
[2]  
[Anonymous], AACN PROTOCOLS PRACT
[3]  
Bern Linda, 2007, Medsurg Nurs, V16, P356
[4]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[5]   Is the accuracy of blood pressure measuring devices underestimated at increasing blood pressure levels? [J].
Braam, RL ;
Thien, T .
BLOOD PRESSURE MONITORING, 2005, 10 (05) :283-289
[6]   The influence of the method of data analysis on the reported accuracy of automated blood pressure measuring devices [J].
Braam, RL ;
Thien, T .
JOURNAL OF HYPERTENSION, 2001, 19 (10) :1765-1767
[7]   Factors influencing the accuracy of oscillometric blood pressure measurement in critically ill patients [J].
Bur, A ;
Herkner, H ;
Vlcek, M ;
Woisetschläger, C ;
Derhaschnig, U ;
Delle Karth, G ;
Laggner, AN ;
Hirschl, MM .
CRITICAL CARE MEDICINE, 2003, 31 (03) :793-799
[8]   Accuracy of oscillometric blood pressure measurement according to the relation between cuff size and upper-arm circumference in critically ill patients [J].
Bur, A ;
Hirschl, MM ;
Herkner, H ;
Oschatz, E ;
Kofler, J ;
Woisetschläger, C ;
Laggner, AN .
CRITICAL CARE MEDICINE, 2000, 28 (02) :371-376
[9]   Sources of variability in blood pressure measurement using the Dinamap PRO 100 automated oscillometric device [J].
Chang, JJ ;
Rabinowitz, D ;
Shea, S .
AMERICAN JOURNAL OF EPIDEMIOLOGY, 2003, 158 (12) :1218-1226
[10]  
Chatburn R L, 1996, AANA J, V64, P261