Added Value of Using a CT Coronal Reformation to Diagnose Adnexal Torsion

被引:28
作者
Jung, Sung Il [1 ]
Park, Hee Sun [1 ]
Yim, Younghee [1 ]
Jeon, Hae Jeong [1 ]
Yu, Mi Hye [1 ]
Kim, Young Jun [1 ]
Jeong, Kyungah [2 ]
机构
[1] Konkuk Univ, Res Inst Med Sci, Dept Radiol, Sch Med, Seoul 143729, South Korea
[2] Ewha Womans Univ, Sch Med, Dept Obstet & Gynecol, Seoul 158710, South Korea
关键词
CT; Adnexa; Torsion; SMALL-BOWEL OBSTRUCTION; MULTIDETECTOR ROW CT; OVARIAN TORSION; ISOTROPIC VOXELS; MULTIPLANAR REFORMATIONS; PATHOLOGICAL CORRELATION; SONOGRAPHIC FINDINGS; DOPPLER SONOGRAPHY; IMAGING FEATURES; AGREEMENT;
D O I
10.3348/kjr.2015.16.4.835
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective: To evaluate the increased value of using coronal reformation of a transverse computed tomography (CT) scan for detecting adnexal torsion. Materials and Methods: This study included 106 woman suspected of having adnexal torsion who underwent CT with coronal reformations and subsequent surgical exploration. Two readers independently recorded the CT findings, such as the thickening of a fallopian tube, twisting of the adnexal pedicle, eccentric smooth wall thickening of the torsed adnexal mass, eccentric septal thickening of the torsed adnexal mass, eccentric poor enhancement of the torsed adnexal mass, uterine deviation to the twisted side, ascites or infiltration of pelvic fat, and the overall impression of adnexal torsion with a transverse scan alone or combined with coronal reformation and a transverse scan. The areas under the receiver operating characteristic curves (AUCs), sensitivity, specificity, and positive predictive value were used to compare diagnostic performance. Results: Fifty-two patients were confirmed to have adnexal torsion. The addition of coronal reformations to the transverse scan improved AUCs for readers 1 and 2 from 0.74 and 0.75 to 0.92 and 0.87, respectively, for detecting adnexal torsion (p < 0.001 and p = 0.004, respectively). Sensitivity of CT for detecting twisting of the adnexal pedicle increased significantly for readers 1 and 2 from 0.27 and 0.29 with a transverse scan alone to 0.79 and 0.77 with a combined coronal reformation and a transverse scan, respectively (p < 0.001 and p < 0.001, respectively). Conclusion: Use of a coronal reformation with transverse CT images improves detection of adnexal torsion.
引用
收藏
页码:835 / 845
页数:11
相关论文
共 29 条
[1]  
Albayram F, 2001, J ULTRAS MED, V20, P1083
[2]   Doppler and gray-scale sonographic classification of adnexal torsion [J].
Auslender, R. ;
Shen, O. ;
Kaufman, Y. ;
Goldberg, Y. ;
Bardicef, M. ;
Lissak, A. ;
Lavie, O. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2009, 34 (02) :208-211
[3]   Multidetector CT: Opportunities, challenges, and concerns associated with scanners with 64 or more detector rows [J].
Boone, John M. .
RADIOLOGY, 2006, 241 (02) :334-337
[4]   Pearls and pitfalls in diagnosis of ovarian torsion [J].
Chang, Hannah C. ;
Bhatt, Shweta ;
Dogra, Vikram S. .
RADIOGRAPHICS, 2008, 28 (05) :1355-1368
[5]   Adnexal torsion - New clinical and imaging observations by sonography, computed tomography, and magnetic resonance imaging [J].
Chiou, See-Ying ;
Lev-Toaff, Anna S. ;
Masuda, Emi ;
Feld, Rick L. ;
Bergin, Diane .
JOURNAL OF ULTRASOUND IN MEDICINE, 2007, 26 (10) :1289-1301
[7]  
COMERCI JT, 1994, OBSTET GYNECOL, V84, P22
[8]   Ovarian Torsion: Diagnostic Features on CT and MRI With Pathologic Correlation [J].
Duigenan, Shauna ;
Oliva, Esther ;
Lee, Susanna I. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) :W122-W131
[9]   BILATERAL TORSION OF THE ADNEXA - A CASE-REPORT AND A REVIEW OF THE WORLD LITERATURE [J].
DUNNIHOO, DR ;
WOLFF, J .
OBSTETRICS AND GYNECOLOGY, 1984, 64 (03) :55-59
[10]   TORSION OF THE OVARY - SONOGRAPHIC FEATURES [J].
GRAIF, M ;
SHALEV, J ;
STRAUSS, S ;
ENGELBERG, S ;
MASHIACH, S ;
ITZCHAK, Y .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1984, 143 (06) :1331-1334