Amperometric sensing of norepinephrine at picomolar concentrations using screen printed, high surface area mesoporous carbon

被引:25
作者
Dai, Mingzhi [1 ]
Haselwood, Brittney [2 ,3 ]
Vogt, Bryan D. [4 ]
La Belle, Jeffrey T. [2 ,3 ]
机构
[1] Arizona State Univ, Chem Engn Program, Tempe, AZ 85287 USA
[2] Arizona State Univ, Biodesign Inst, Tempe, AZ 85287 USA
[3] Arizona State Univ, Harrington Program Biomed Engn, Sch Biol & Hlth Syst Engn, Tempe, AZ 85287 USA
[4] Univ Akron, Dept Polymer Engn, Akron, OH 44325 USA
基金
美国国家科学基金会;
关键词
Norepinephrine; Sensor; Mesoporous carbon; Electrochemistry; Self-assembly; Porous materials; PHENYLETHANOLAMINE N-METHYLTRANSFERASE; ELECTRODE MATERIAL; CAPILLARY-ELECTROPHORESIS; ELECTROCHEMICAL SENSOR; PASTE ELECTRODES; FOLIC-ACID; EPINEPHRINE; ACETAMINOPHEN; 5-HYDROXYTRYPTAMINE; CHROMATOGRAPHY;
D O I
10.1016/j.aca.2013.06.019
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Norepinephrine (NE) is detected amperometrically using the enzyme Phenylethanolamine N-methyl transferase and cofactor S-(5'-Adenosyl)-L-methionine chloride dihydrochloride with disposable screen printed mesoporous carbon electrodes. The role of internal surface area and pore size of the mesoporous carbon is systematically examined using soft-templated, mesoporous silica-carbon powders with highly microporous walls obtained from etching of the silica to produce powders with surface areas ranging from 671-2339 m(2) g(-1). As the surface area increases, the sensitivity of the biosensor at very low NE concentrations (0-500 pg mL(-1)) in phosphate buffered saline (PBS) increases just as the current signal increases with respect to the NE concentration of 81-1581 mu A mL ng(-1) cm(-2) for the mesoporous carbons. The best performing electrode provides similar sensitivity in whole rabbit blood in comparison to PBS despite no membrane layer to filter the non-desired reactants; the small (<5 nm) pore size and large internal surface area acts to minimize non-specific events that decrease sensitivity. Published by Elsevier B.V.
引用
收藏
页码:32 / 38
页数:7
相关论文
共 42 条
[1]  
Akhgar M. R., 2012, ANAL METHODS, V4, P5
[2]  
AXELROD J, 1962, J BIOL CHEM, V237, P1657
[3]  
Bamberg Richard, 2005, Clin Lab Sci, V18, P203
[4]   In situ growth of copper sulfide nanoparticles on ordered mesoporous carbon and their application as nonenzymatic amperometric sensor of hydrogen peroxide [J].
Bo, Xiangjie ;
Bai, Jing ;
Wang, Lixia ;
Guo, Liping .
TALANTA, 2010, 81 (1-2) :339-345
[5]   A simple and rapid HPLC-MS method for the simultaneous determination of epinephrine, norepinephrine, dopamine and 5-hydroxytryptamine: Application to the secretion of bovine chromaffin cell cultures [J].
Carrera, Victoria ;
Sabater, Esther ;
Vilanova, Eugenio ;
Sogorb, Miguel A. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 847 (02) :88-94
[6]   Nanosensors and nanomaterials for monitoring glucose in diabetes [J].
Cash, Kevin J. ;
Clark, Heather A. .
TRENDS IN MOLECULAR MEDICINE, 2010, 16 (12) :584-593
[7]   Carbon nanotubes paste electrodes as new detectors for capillary electrophoresis [J].
Chicharro, M ;
Sánchez, A ;
Bermejo, E ;
Zapardiel, A ;
Rubianes, MD ;
Rivas, GA .
ANALYTICA CHIMICA ACTA, 2005, 543 (1-2) :84-91
[8]   High capacity magnetic mesoporous carbon-cobalt composite adsorbents for removal of methylene green from aqueous solutions [J].
Dai, Mingzhi ;
Vogt, Bryan D. .
JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2012, 387 :127-134
[9]   Mesoporous carbon amperometric glucose sensors using inexpensive, commercial methacrylate-based binders [J].
Dai, Mingzhi ;
Maxwell, Stephanie ;
Vogt, Bryan D. ;
La Belle, Jeffrey T. .
ANALYTICA CHIMICA ACTA, 2012, 738 :27-34
[10]   Drug effects on the electrochemical detection of norepinephrine with carbon fiber and diamond microelectrodes [J].
Dong, Hua ;
Wang, Shihua ;
Liu, Aihua ;
Galligan, James J. ;
Swain, Greg M. .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2009, 632 (1-2) :20-29