Fault location in transmission lines using one-terminal postfault voltage data

被引:1
作者
De Pereira, CE [1 ]
Zanetta, LC [1 ]
机构
[1] Univ Sao Paulo, Escola Politecn, BR-05508900 Sao Paulo, Brazil
关键词
distance measurement; EHV transmission lines; fault diagnosis; fault location;
D O I
10.1109/TWPRD.2004.824391
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A new algorithm for fault location in transmission lines, with fault distance calculation based on steady-state measured phasors in local terminal is presented. For the postfault, only voltage phasors are required, avoiding possible errors due to current transformer saturation; the current phasors are required only in prefault time, when saturation does not occur. The algorithm does not use simplifying hypothesis but requires system equivalent data at both line terminals and the fault classification, considering fault resistance purely resistive. In order to verify the algorithm performance, a parametric analysis of variables that influences short-circuit conditions is developed, including an analysis of remote equivalent setting. The results show that the algorithm is very accurate, even in cases when the remote equivalent is not well fitted.
引用
收藏
页码:570 / 575
页数:6
相关论文
共 13 条
[1]  
[Anonymous], 1987, ATP ALT TRANS PROGR
[2]  
[Anonymous], [No title captured]
[3]   Distance protection and fault location utilizing only phase current phasors [J].
Djuric, MB ;
Radojevic, ZM ;
Terzija, VV .
IEEE TRANSACTIONS ON POWER DELIVERY, 1998, 13 (04) :1020-1026
[4]  
Ferrer A, 2001, J INVEST ALLERG CLIN, V11, P199
[5]   A NEW FAULT LOCATION TECHNIQUE FOR 2-TERMINAL AND 3-TERMINAL LINES [J].
GIRGIS, AA ;
HART, DG ;
PETERSON, WL .
IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) :98-107
[6]   Fault location using the distributed parameter transmission line model [J].
Gopalakrishnan, A ;
Kezunovic, M ;
McKenna, SM ;
Hamai, DM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) :1169-1174
[7]   NEW TECHNIQUE FOR THE ACCURATE LOCATION OF EARTH FAULTS ON TRANSMISSION-SYSTEMS [J].
JOHNS, AT ;
MOORE, PJ ;
WHITTARD, R .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 1995, 142 (02) :119-127
[8]   ACCURATE FAULT LOCATION TECHNIQUE FOR POWER TRANSMISSION-LINES [J].
JOHNS, AT ;
JAMALI, S .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1990, 137 (06) :395-402
[9]   EXPERIMENTAL EVALUATION OF EMTP-BASED CURRENT TRANSFORMER MODELS FOR PROTECTIVE RELAY TRANSIENT STUDY [J].
KEZUNOVIC, M ;
KOJOVIC, L ;
ABUR, A ;
FROMEN, CW ;
SEVCIK, DR ;
PHILLIPS, F .
IEEE TRANSACTIONS ON POWER DELIVERY, 1994, 9 (01) :405-412
[10]   Automated transmission line fault analysis using synchronized sampling at two ends [J].
Kezunovic, M ;
Perunicie, B .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1996, 11 (01) :441-447