The State of the Art on the Use of Oral Fluid as Alternative Specimen in Forensic Toxicology

被引:16
作者
De Giovanni, Nadia [1 ]
Fucci, Nadia [1 ]
机构
[1] Univ Cattolica Sacro Cuore, Inst Legal Med, I-00168 Rome, Italy
关键词
Oral fluid; Review; Forensic applications;
D O I
10.2174/157341208786306180
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Oral fluid is a readily available specimen which can be collected by non invasive procedures and contains many drugs of interest in screening and diagnosis. It is obtained by a painless and non invasive method of sampling; it contains the free fraction of drugs and therefore it could be a good indicator of intoxication state. Oral fluid in fact has the potential for supplying interpretation with respect to blood concentration and impairment with similar detection windows to blood. Drugs of abuse have been investigated in oral fluid for more than twenty years, because of a number of advantages compared to the body fluids traditionally used as substrates for therapeutic drug monitoring, that is blood and plasma, and actually their analysis is becoming more widely used and accepted across a number of testing disciplines. This review summarizes the studies on the determination of different drugs of abuse in oral fluid in the last eight years to elucidate the current status in this area. To obtain useful information about the correct employ of oral fluid in forensic toxicology, the study of some parameters such as collection, storage and stability of drugs, is required. Moreover analytical aspects and interpretation of results must be evaluated. For this purpose the analysis of the latter scientific literature is discussed in detail for the knowledge of the state of the art, with respect to some forensic aspects such as driving impairment or workplace drug testing.
引用
收藏
页码:258 / 273
页数:16
相关论文
共 165 条
[1]  
Al Za'abi M, 2003, ACTA NEUROL BELG, V103, P19
[2]   Replacement of immunoassay by LC tandem mass spectrometry for the routine measurement of drugs of abuse in oral fluid [J].
Allen, KR ;
Azad, R ;
Field, HP ;
Blake, DK .
ANNALS OF CLINICAL BIOCHEMISTRY, 2005, 42 :277-284
[3]   Implications for diagnostics in the biochemistry and physiology of saliva [J].
Amerongen, Arie v. Nieuw ;
Ligtenberg, Antoon J. M. ;
Veerman, Enno C. I. .
ORAL-BASED DIAGNOSTICS, 2007, 1098 :1-6
[4]   Review: The physiology of saliva and transfer of drugs into saliva [J].
Aps, JKM ;
Martens, LC .
FORENSIC SCIENCE INTERNATIONAL, 2005, 150 (2-3) :119-131
[5]   THE ROLE OF SALIVARY MEASUREMENTS IN THE DIAGNOSIS OF SALIVARY AUTOIMMUNE-DISEASES [J].
ATKINSON, JC .
ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1993, 694 :238-251
[6]   Sensitivity, specificity, and efficiency in detecting opiates in oral fluid with the Cozart® opiate microplate EIA and GC-MS following controlled codeine administration [J].
Barnes, AJ ;
Kim, I ;
Schepers, R ;
Moolchan, ET ;
Wilson, L ;
Cooper, G ;
Reid, C ;
Hand, C ;
Huestis, MA .
JOURNAL OF ANALYTICAL TOXICOLOGY, 2003, 27 (07) :402-406
[7]   Comparison of point-of-collection screening of drugs of abuse in oral fluid with a laboratory-based urine screen [J].
Barrett, C ;
Good, C ;
Moore, C .
FORENSIC SCIENCE INTERNATIONAL, 2001, 122 (2-3) :163-166
[8]   Medicinal and illegal drugs among Danish car drivers [J].
Behrensdorff, I ;
Steentoft, A .
ACCIDENT ANALYSIS AND PREVENTION, 2003, 35 (06) :851-860
[9]  
BEMHOFT IM, 2005, FORENSIC SCI INT, V150, P181
[10]   Is oral fluid analysis as accurate as urinalysis in detecting drug use in a treatment setting? [J].
Bennett, GA ;
Davies, E ;
Thomas, P .
DRUG AND ALCOHOL DEPENDENCE, 2003, 72 (03) :265-269